• Title/Summary/Keyword: Ultrasonic system

Search Result 1,514, Processing Time 0.034 seconds

An Accurate Moving Distance Measurement Using the Rear-View Images in Parking Assistant Systems (후방영상 기반 주차 보조 시스템에서 정밀 이동거리 추출 기법)

  • Kim, Ho-Young;Lee, Seong-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.12
    • /
    • pp.1271-1280
    • /
    • 2012
  • In the recent parking assistant systems, finding out the distance to the object behind a car is often performed by the range sensors such as ultrasonic sensors, radars. However, the installation of additional sensors on the used vehicle could be difficult and require extra cost. On the other hand, the motion stereo technique that extracts distance information using only an image sensor was also proposed. However, In the stereo rectification step, the motion stereo requires good features and exacts matching result. In this paper, we propose a fast algorithm that extracts the accurate distance information for the parallel parking situation using the consecutive images that is acquired by a rear-view camera. The proposed algorithm uses the quadrangle transform of the image, the horizontal line integral projection, and the blocking-based correlation measurement. In the experiment with the magna parallel test sequence, the result shows that the line-accurate distance measurement with the image sequence from the rear-view camera is possible.

Tele-operation of a Mobile Robot Using Force Reflection Joystick with Single Hall Sensor (단일 홀센서 힘반영 조이스틱을 이용한 모바일 로봇 원격제어)

  • Lee, Jang-Myung;Jeon, Chan-Sung;Cho, Seung-Keun
    • The Journal of Korea Robotics Society
    • /
    • v.1 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • Though the final goal of mobile robot navigation is to be autonomous, operators' intelligent and skillful decisions are necessary when there are many scattered obstacles. There are several limitations even in the camera-based tele-operation of a mobile robot, which is very popular for the mobile robot navigation. For examples, shadowed and curved areas cannot be viewed using a narrow view-angle camera, especially in bad weather such as on snowy or rainy days. Therefore, it is necessary to have other sensory information for reliable tele-operations. In this paper, sixteen ultrasonic sensors are attached around a mobile robot in a ring pattern to measure the distances to obstacles. A collision vector is introduced in this paper as a new tool for obstacle avoidance, which is defined as a normal vector from an obstacle to the mobile robot. Based on this collision vector, a virtual reflection force is generated to avoid the obstacles and then the reflection force is transferred to an operator who is holding a joystick to control the mobile robot. Relying on the reflection force, the operator can control the mobile robot more smoothly and safely. For this bi-directional tele-operation, a master joystick system using a hall sensor was designed to resolve the existence of nonlinear sections, which are usual for a general joystick with two motors and potentiometers. Finally, the efficiency of a force reflection joystick is verified through the comparison of two vision-based tele-operation experiments, with and without force reflection.

  • PDF

Nanocrystalline Diamond Coated SiC Balls in Tribometer (나노결정질 다이아몬드가 코팅된 SiC 마모시험기 볼)

  • Im, Jong Hwan;Kang, Chan Hyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.5
    • /
    • pp.263-268
    • /
    • 2014
  • Nanocrystalline diamond(NCD) coated SiC balls were applied in a ball-on-disk tribometer. After seeding in an ultrasonic bath containing nanometer diamond powders, $2.2{\mu}m$ thick NCD films were deposited on sintered 3 mm diameter SiC balls at $600^{\circ}C$ in a 2.45 GHz microwave plasma CVD system. Bare $ZrO_2$ and SiC balls were prepared for comparison as test balls. Tribology tests were performed in air with pairs of three different balls and mirror polished steel(SKH51) disk. The wear tracks on balls and disks were examined by optical microscope and alpha step profiler. Under the load of 3 N, the friction coefficients of steel against $ZrO_2$, SiC and NCD-coated balls were between 0.4 and 0.8. After a few thousands sliding laps, the friction coefficient of NCD-coated balls dropped from 0.45 to below 0.1 and maintained thereafter. Under a higher load of 10 N or 20 N with a long sliding distance of 2 km, $ZrO_2$ and SiC balls exhibited the similar friction coefficients as above. The friction coefficient of NCD-coated balls was less than 0.1 from the beginning and increased to above 0.1 steadily or with some fluctuations as sliding distance increased. NCD coating layers were found worn out after long duration and/or high load sliding test, which resulted in the friction coefficient higher than 0.1.

Decontamination methods to restore the biocompatibility of contaminated titanium surfaces

  • Jin, Seong-Ho;Lee, Eun-Mi;Park, Jun-Beom;Kim, Kack-Kyun;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.3
    • /
    • pp.193-204
    • /
    • 2019
  • Purpose: The reaction of cells to a titanium implant depends on the surface characteristics of the implant which are affected by decontamination. The aim of this study was to evaluate the cytocompatibility of titanium disks treated with various decontamination methods, using salivary bacterial contamination with dental pellicle formation as an in vitro model. Methods: Sand-blasted and acid-etched (SA) titanium disks were used. Three control groups (pristine SA disks [SA group]; salivary pellicle-coated SA disks [pellicle group]; and biofilm-coated, untreated SA disks [NT group]) were not subjected to any decontamination treatments. Decontamination of the biofilm-coated disks was performed by 14 methods, including ultrasonic instruments, rotating instruments, an air-powder abrasive system, a laser, and chemical agents. MG63 cells were cultured in the presence of the treated disks. Cell proliferation assays were performed on days 2 and 5 of cell culture, and cell morphology was analyzed by immunofluorescence and scanning electron microscopy (SEM). A vascular endothelial growth factor (VEGF) assay was performed on day 5 of culture. Results: The cell proliferation assay revealed that all decontaminated disks, except for the 2 groups treated using a plastic tip, showed significantly less cell proliferation than the SA group. The immunofluorescence and SEM analyses revealed that most groups showed comparable cell density, with the exception of the NT group, in which the cell density was lower and bacterial residue was observed. Furthermore, the cells grown with tetracycline-treated titanium disks showed significantly lower VEGF production than those in the SA group. Conclusions: None of the decontamination methods resulted in cytocompatibility similar to that of pristine SA titanium. However, many methods caused improvement in the biocompatibility of the titanium disks in comparison with the biofilm-coated, untreated titanium disks. This suggests that decontamination is indispensable for the treatment of peri-implantitis, even if the original biocompatibility cannot be restored.

Effect of Visual Feedback Squat Motion on Core Muscles Thickness of Young People with Lower Back Pain

  • Jeong, HoJin;Park, ChiBock;Kim, YongNam
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.4
    • /
    • pp.216-221
    • /
    • 2019
  • Purpose: This study examined the effect of visual feedback squat on the core muscle thickness of young adults experiencing back pain. Methods: Thirty adult men and women who experienced back pain were assigned randomly to 15 members of the visual feedback squat group (VSG) and 15 of the normal squat group (NSG) to train three times a week for a total of eight weeks. The core muscle thickness was compared prior to the test for four weeks and eight weeks after the test by dividing it into warm-up exercise, main exercise, and 10 minutes finishing exercise. Before, and four weeks and eight weeks later, the thickness of the core muscle was compared using an ultrasonic imaging system. Repeated measured ANOVA was performed to compare the groups, and a Bonferroni test was performed as a post-hoc test to assess the significance of the timing of the measurements in each group according to the periods. An independent t-test was conducted to test the significance between the groups according to the measurement points. Results: A significant change in the main effects of time and interactions of the time difference in muscle thickness of transvers abdominis were observed between the visual feedback squat and control groups according to the measurement point (p<0.05). No significant difference in the muscle thickness of both muscles was observed between the groups with the exception of the right abdominis (p>0.05). Conclusion: These findings suggest that visual feedback squat exercise is expected to have positive effects on the development of transverse abdominis in core muscles.

A study on speed-sensitive vehicle brake light system using LED (LED를 이용한 속도 감응형 차량용 브레이크등 시스템)

  • Kim, Tae-Jin;Kim, Hyung-Jun;Park, Seong-Jun;Park, In-Soo;Park, Sung-Won;Kim, Sung-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.809-810
    • /
    • 2016
  • In this study, Speed-sensitive vehicle brake using the LED, When the driver presses the brake pedal, range step while being turned in connection taillights brake of the vehicle, such as speed-sensitive vehicle brake using the LED, It is turned on according to the deceleration of the vehicle to be series of points are displayed. The rear vehicle can prevent collision about an abrupt stop of preceding vehicle by perceiving deceleration state of preceding vehicle easier and faster. Also, if the inter-vehicle distance by using an ultrasonic sensor is closer than a certain distance, the emergency light turns on to convey the situation to the driver of the rear vehicle with a buzzer.

  • PDF

Optimization of Extraction Conditions for Swertiamarin in Swertia japonica Makino (당약의 swertiamarin 분석을 위한 추출조건 최적화)

  • Kim, Tae Hee;Jang, Seol;Lee, Ah Reum;Lee, A Young;Choi, Goya;Kim, Ho Kyoung
    • The Korea Journal of Herbology
    • /
    • v.29 no.1
    • /
    • pp.13-18
    • /
    • 2014
  • Objectives : Iridoid glycoside, swertiamarin is a well known bioactive component found in Swertia japonica Makino (SJ). In this study, we tried to optimize a suitable method which would extract swertiamarin effectively. Methods : Extraction of SJ was carried out by various conditions of time (5 - 60 min), temperature ($30-70^{\circ}C$), solvent (from non-polar to polar), and ratio of solvnet / sample (10 : 1 - 40 : 1) using ultrasonic extractor. Swertiamarin in SJ extracts was quantified by high performance liquid chromatography - Phtodiode array detector (HPLC-PDA) using C18 column and the analytical procedure was validated by evaluation of specificity, range, linearity, accuracy (recovery), precision (intra- and inter day variability), limit of detection (LOD), and limit of quantification (LOQ). Results : An efficient extraction condition for swertiamarin in SJ was optimized using sonicator extraction (temperature $40^{\circ}C$, solvent 20% methanol, solvent / sample (20 : 1), and time 10 min. Analytical procedure was optimized by HPLC-PDA using isocratic solvent system of acetonitrile and water (9 : 91), and the method was validated in regard to linearity (correlation coefficient, $R^2$ > 0.9999), range ($50-1000{\mu}g/mL$), intra- and inter-precision (RSD < 5.0 %), and recovery (99 -103 %). LOD and LOQ were 0.051 and $0.155{\mu}g/mL$, respectively. Conclusion : An optimized method of extraction for swertiamarin in SJ was established through conditions of diverse extraction and the validation result indicated that the method is suited for the determination of swertiamarin in SJ.

Application of AI models for predicting properties of mortars incorporating waste powders under Freeze-Thaw condition

  • Cihan, Mehmet T.;Arala, Ibrahim F.
    • Computers and Concrete
    • /
    • v.29 no.3
    • /
    • pp.187-199
    • /
    • 2022
  • The usability of waste materials as raw materials is necessary for sustainable production. This study investigates the effects of different powder materials used to replace cement (0%, 5% and 10%) and standard sand (0%, 20% and 30%) (basalt, limestone, and dolomite) on the compressive strength (fc), flexural strength (fr), and ultrasonic pulse velocity (UPV) of mortars exposed to freeze-thaw cycles (56, 86, 126, 186 and 226 cycles). Furthermore, the usability of artificial intelligence models is compared, and the prediction accuracy of the outputs is examined according to the inputs (powder type, replacement ratio, and the number of cycles). The results show that the variability of the outputs was significantly high under the freeze-thaw effect in mortars produced with waste powder instead of those produced with cement and with standard sand. The highest prediction accuracy for all outputs was obtained using the adaptive-network-based fuzzy inference system model. The significantly high prediction accuracy was obtained for the UPV, fc, and fr of mortars produced using waste powders instead of standard sand (R2 of UPV, fc and ff is 0.931, 0.759 and 0.825 respectively), when under the freeze-thaw effect. However, for the mortars produced using waste powders instead of cement, the prediction accuracy of UPV was significantly high (R2=0.889) but the prediction accuracy of fc and fr was low (R2fc=0.612 and R2ff=0.334).

Weather Data-Based Coordination Recommendation Smart Wardrobe System (날씨 데이터 기반 코디추천 스마트옷장 시스템)

  • Lee, Tae-Hun;Jeong, Hui;Kwon, Jang-Ryong;Baek, Pil-Gyu;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.729-738
    • /
    • 2022
  • Existing wardrobes have been used only for storing simple clothes. Since it has a function to store clothes, there is only one way to control the environment such as humidity or temperature, and there is only one way to purchase and store items such as a desiccant. In this paper, by increasing the convenience in the existing wardrobe, automatic temperature and humidity control and various convenient functions were added. In line with the smart home market and smart phone application market that have grown over the past several years, along with the development of a wardrobe with sensors, the temperature and humidity control function and other functions inside the wardrobe through Bluetooth pairing between the wardrobe and the smartphone can be customized to the user using a smartphone. Through the clothing selection function and the weather data in the application, we want to implement convenient functions such as the function of recommending clothes in the closet to match the weather.

Comparison of the Ratio of Thicknesses of the Rhomboid Major and Middle Trapezius Muscles While Performing Scapular Retraction Exercises (어깨뼈 뒤 당김 운동 방법에 따른 큰마름근과 중간등세모근의 근두께비의 비교)

  • Park, Heon-mi;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • Background: Shoulder impingement syndrome, a major cause of shoulder pain, involves weakness of the scapular retractor muscles. The major scapular retractor muscles are the middle trapezius and rhomboid major muscles; however, the latter is excluded in most studies. Objects: We aimed to measure the thickness of the middle trapezius and rhomboid major muscles using an ultrasonic diagnostic imaging system while performing four different shoulder retraction exercises and comparing the thicknesses and ratio of the thicknesses of these muscles. Methods: The thickness of the middle trapezius and rhomboid major muscles was measured in 24 healthy adults using ultrasound. Muscle thickness was measured three times in the Reference posture and four times while performing four different exercises that involved scapular retraction. The averages and standard deviations of the measured muscle thicknesses were obtained and compared. The ratio of muscle thickness and rate of changes in muscle thickness between the reference posture and the four exercises were compared. Results: For both, male (n = 10) and female (n = 14), there was a significant difference in the thickness of the middle trapezius muscle between the reference posture and the four exercises (p < 0.05) and in the thickness of the middle trapezius and rhomboid major muscles between male and female (p < 0.05); however, there was no significant difference in the ratio of the thicknesses of these muscles. Although a significant difference in the rate of change in muscle thickness during the four exercises was noted, there was no significant difference in the ratio of change in muscle thickness. Conclusion: This study demonstrates the ratio of the thicknesses of the middle trapezius and rhomboid major muscles and the rate of change in their thickness during exercises involving scapular retraction in healthy people in their 20s-30s.