• Title/Summary/Keyword: Ultrasonic probe

Search Result 160, Processing Time 0.02 seconds

Ultrasonic Sensors for Steel Structure Inspection (강구조물(鋼構造物) 진단(診斷)을 위한 초음파(超音波) 센서)

  • Shin, Byoung-Churl
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.2
    • /
    • pp.170-176
    • /
    • 1998
  • The team mixed PbO, $ZrO_2$, $TiO_2$, $Nb_2O_5$ and $MnCO_3$, to make $Pb[(Zr_{0.54}\;Ti_{0.46})\;Nb_{0.005}]O_3+4%MnCO_3$. The electroded PZT ceramics were poled by 3 kV/mm at $110^{\circ}C$ for 600 s. We assembled the 0.4mm thick PZT slices into ultrasonic transducers. Central frequency of the probe is 5 MHz, which is proper to the thickness gauge for steel pipes and for flaw detector. The probe can detect a disk shape defect of 1mm diameter at 15cm deep in steel block. The new probe's Fresnel zone that the ultrasonic beam do not broaden is 13mm. Over the Fresnel zone, the ultrasonic beam spreads. Half of the beam spread angle of the probe is $4.3^{\circ}-4.6^{\circ}$. This probe can be used for the ultrasonic transducers for non-destructive testing of steel bridges.

  • PDF

Influence to the Doppler Images by the Defects of SAE in the Probe of Medical Ultrasonic Scanners (초음파 프로브에서 인접 단위 소자군(SAE) 결함이 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • A ultrasonic probe is very important in medical ultrasonic image, but the frequency of probe defects are often. Therefore practical tools for probe based ultrasonic QA should be developed. Advanced research on the effects of the probe defects on the quality of ultrasonic images is required. This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. Especially the defects in a set of adjacent elements(SAE) electrically disconnected influence Doppler images were tested. The results show Doppler brightness and velocity became rapidly reduced as the defected elements is located centrally, as the defected elements is activated. The more the defected elements increased, the more Doppler brightness and velocity increased. As a set of the element disconnected moved, it appeared Doppler velocity starting to decrease and then was followed by brightness. The strength is not consistent with the velocity in the number and location of the defected elements. The defects in the probe elements influence Doppler velocity when the defected elements got out of the elements activated at Doppler mode.

Spatial Compounding of Ultrasonic Diagnostic Images for Rotating Linear Probe with Geometric Parameter Error Compensation

  • Choi, Myoung Hwan;Bae, Moo Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1418-1425
    • /
    • 2014
  • In ultrasonic medical imaging, spatial compounding of images is a technique where ultrasonic beam is steered to examine patient tissues in multiple angles. In the conventional ultrasonic diagnostic imaging, the steering of the ultrasonic beam is achieved electronically using the phased array transducer elements. In this paper, a spatial compounding approach is presented where the ultrasonic probe element is rotated mechanically and the beam steering is achieved mechanically. In the spatial compounding, target position is computed using the value of the rotation axis and the transducer array angular position. However, in the process of the rotation mechanism construction and the control system there arises the inevitable uncertainties in these values. These geometric parameter errors result in the target position error, and the consequence is a blurry compounded image. In order to reduce these target position errors, we present a spatial compounding scheme where error correcting transformation matrices are computed and applied to the raw images before spatial compounding to reduce the blurriness in the compounded image. The proposed scheme is illustrated using phantom and live scan images of human knee, and it is shown that the blurriness is effectively reduced.

Development of a Ultrasound Probe for 3-D Ultrasonic Imaging (3차원 의료기기용 초음파진단기 프로브 개발)

  • Park, Jong-Soo;Kim, Seong-Rae;Nam, Yoon-Su
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.87-93
    • /
    • 2005
  • Three-dimensional ultrasonic probes being applied to the medical imaging can be grouped into three depending on the scanning methods, which are a mechanical type system, a free-hand system, and 2D phased arrays system. A mechanical type scanner uses a mechanically driven transducer to acquire series of 2D plane images. By integrating these images, a 3-D medical image can be constructed. A motor driving mechanism is a conventional choice for mechanically driving a transducer assembly which picks the raw ultrasonic images up. In this paper we attempt to design a 3D ultrasonic probe which has a operating mechanism of s tilting 3-D scanning. The motion of a transducer assembly of the ultrasonic probe is analytically modelled. We propose a selection procedure for the diameter of a wire rope driving the transducer assembly and the size of torsional spring which gives an initial tension to wire ropes.

  • PDF

Propagation Characteristic of Ultrasonic on Slit Defect in Butt Joint (맞대기 용접부내의 인공 결함에서 초음파의 전파특성)

  • 남영현
    • Journal of Welding and Joining
    • /
    • v.14 no.6
    • /
    • pp.37-47
    • /
    • 1996
  • An ultrasonic testing uses the directivity of the ultrasonic wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of ultrasonic wave is related to determination of testing sensitivity, scanning pitch and defect location. This paper investigated the directivity of ultrasonic wave, which scattered from slit defect located in heat-affected zone (HAZ) in butt joint using visualization method. The directivity of shear waves scattered from slit defect were different according to probe direction (far defect, near defect) and probe position (forward movement, maximum echo position, backward movement). The difference of directivity of reflection wave was existed between 2 MHz and 4 MHz angle probes. In the case of 2 MHz angle probe, the directivity of reflection wave was appeared sharp form because of the relation wave length and defect size.

  • PDF

Study on enhancing the ultrasonic image for bone densitometry (골밀도 측정을 위한 초음파 영상 개선에 관한 연구)

  • Shin, Jung-Sik;Ahn, Jung-Hwan;Kim, Hyung-Joon;Kim, Hwa-Young;Han, Seung-Moo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.182-191
    • /
    • 2005
  • It is very important to obtain a high quality of bone image for an accurate ultrasonic measurement of bone mineral density. In this study, we suggested a technique to acquire an optimal image by adapting an acoustic lens and a properly selected ultrasonic probe. Also, we have applied an image processing algorithm with which automatically makes a decision of brightness and contrast of image by generating threshold level, a composition of ultrasonic data, an elimination of noise using modified median filter, and a real time interpolation. We could confirm much improved resolution of bone image with acoustic lens attached to the ultrasonic probe and with the image processing algorithm suggested in this study. Therefore, it became possible to precisely diagnose the osteoprosis using ultrasonic imaging technique.

Measurement of the Crack Height using the Two-Probe Ultrasonic Diffraction Method. (초음파회절방법(超音波回折方法)을 이용한 귀렬(龜裂)의 높이 측정(測定))

  • Lee, Jae-Ok;Lee, Seung-Kyu;Kim, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.2
    • /
    • pp.35-41
    • /
    • 1988
  • The optimum test conditions of measuring the crack height were determined for the two-probe ultrasonic diffraction method. The applicability and the accuracy of the two-probe ultrasonic diffraction method on the inclined artificial cracks and the fatigue cracks were evaluated. It us possible to measure the height of the normal and inclined artificial cracks with the maximum error of ${\pm}\;0.5mm$ with the two-probe ultrasonic diffraction method. It was found, however, that the accuracy of this method in meaasuring the height of the fatigue crack depends on the degree of closure of the crack tip. It was desirable to choose a refraction angle as small as possible, but the angle should not be so small that the distortion of the lateral waveform became appreciable.

  • PDF

Design and Performance Evaluation of Shear Wave Phased Array Ultrasonic Transducer (횡파 위상배열 초음파 탐촉자 설계 및 성능 평가)

  • Yoon, Byung-Sik;Lee, Hee-Jong;Braconnier, Dominique
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.185-191
    • /
    • 2012
  • Typically, a wedge is involved to generate effectively high inspection angle in pipe weld inspection using phased array ultrasonic technique. But the usage of this wedge for weld or access limited area can cause coverage limitation for the examination volume because of the wedge front length. Therefore, the shear wave phased array probe which can generate high inspection angle without wedge is essentially necessary. In this paper, the shear wave phased array ultrasonic probe which can generate high inspection angle designed by modeling and manufactured from the modelling result. And this shear wave probe tested whether it can detect and sizing for EDM test block that contains various depth. As results, the experimental results show that the designed shear wave phased array probe can detect and size with reliable accuracy. Therefore if this phased array probe apply in field inspection, it is expected that it show more reliable inspection result for plant structure having access limitation.

A Study on the Wave Modes in Measurements of the Crack Depth of Concrete by Ultrasonic Waves (초음파에 의한 콘크리트의 균열깊이 측정에 있어서 음파모드에 관한 연구)

  • Han, E.K.;Lee, S.H.;Kim, J.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.39-47
    • /
    • 1989
  • As the necessity of the safety diagnosis of the concrete structure, more reliable ultrasonic technique to qualify the concrete is required. In this study, the artificial surface crack depth is measured using several types of the ultrasonic probes. As results, the horizontal shear wave probe is most useful to determine the crack depth compared to the other probes. For the surface wave probe, the ultrasonic wave path is changed with the surface crack depth.

  • PDF

Feasibility Study for Low Pressure Turbine Inspection of Nuclear Power Plant Using Shear Wave Phased Array Ultrasonic Transducer (횡파 위상배열 초음파탐촉자를 이용한 원자력발전소 저압 터빈 검사 적용 타당성 연구)

  • Yoon, Byung Sik;Kim, Yong Sik;Kim, Jin Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.8-14
    • /
    • 2013
  • Steam turbine blades and discs of nuclear power plants are one of the most highly stressed areas of turbine rotor, and periodic inspection of the blade roots is essential for monitoring integrity and preventing turbine failure. Ultrasonic technique is applied for volumetric inspection of blade root. However, the complexity of blade root geometry imposes challenges to inspection of blades and discs. Recently, phased array ultrasonic inspection technology is being applied to numerous power generation inspection applications including turbine rotor. The phased array ultrasonic technique requires customized inspection wedges which are generally necessary to generate effectively higher incident angle. But the usage of this wedge can cause access limitation for the lower stage blades of turbine because of the wedge front length. Therefore, the shear wave phased array probe which can generate high inspection angle without wedge is essentially necessary. In this study, feasibility study is conducted for the shear wave phased array ultrasonic probe application to blade and disc inspection. As results, the experimental results show that the shear wave phased array probe can detect the flaw and measure its size with reliable accuracy. Therefore if this shear wave phased array probe is applied to field inspection of blade and disc, more reliable inspection is expected for turbine having access limitation.