• 제목/요약/키워드: Ultrasonic images

검색결과 248건 처리시간 0.024초

공간합성된 초음파 의료영상에서 FIR 필터를 이용한 심라인 감소방법 (Reduction of Seam Line Using an FIR Filter in Spatially Compounded Ultrasonic Diagnostic Images)

  • 최명환
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.129-133
    • /
    • 2008
  • A method to reduce seam line artifact in spatial compounding of ultrasonic images is presented. Spatial compounding is a speckle reducing imaging technique in which a number of ultrasound images of a given target that have been obtained from multiple view angles are combined into a single compounded image by combining the data received from each data point in the compounded image. Since different view angle results in different view area, and the images of different view arms are combined into an image, the compounded image consists of regions with different signal to noise ratio, and the boundary lines between these regions are visible as seam lines in the compounded images. In this paper, we present an algorithm that reduces the visibility of this seam line in the spatially compounded images. Design procedure for a FIH filter is described and the results of applying the filter to in-vivo ultrasonic images are analyzed.

  • PDF

비파괴 초음파 검사법의 의학적 활용: 초음파 C 스캔 영상을 이용한 미세 골절의 진단 (Medical Application of the Nondestructive Ultrasonic Tests: Diagnosis of Micro Bone Fractures using Ultrasonic C Scan Images)

  • 최민주
    • 비파괴검사학회지
    • /
    • 제22권4호
    • /
    • pp.377-385
    • /
    • 2002
  • 비전리 방사선을 이용하는 초음파 탐상법은 안전하며 사용이 간편하기 때문에 비파괴검사에서 매우 선호되고 있는 방법이다. 의학적으로 초음파 탐상법은 동일한 원리를 이용하여 인체의 결함 즉 질병의 진단을 위해 유용한 수단 요로 활용되고 있다. 본 논문에서는 초음파 탐상법에 기반한 의료용 초음파 진단의 원리에 대해 개관하고, 그동안 임상적으로 별로 주목받지 못한 초음파 C스캔 영상을 이용한 치밀골의 미세 골절 진단 가능성을 실험적으로 평가하였다. 실험에서는 돼지 대퇴골에 3점 굽힘 힘 (2-4 kN)을 1 mm/min 속도로 가해 미세 골절을 유발하였다. 골절의 정도를 변화하면서 골절에 대한 엑스선 영상과 25 MHz 접속형 초음파 변환기롤 이용하여 C스캔 영상을 취득하였다. 실험 결과 초음파 C 스캔 영상은 기존의 골절 진단법인 엑스선 영상에서는 진단이 어려운 미세한 골절까지 감지할 수 있음을 확인하였다.

Spatial Compounding of Ultrasonic Diagnostic Images for Rotating Linear Probe with Geometric Parameter Error Compensation

  • Choi, Myoung Hwan;Bae, Moo Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1418-1425
    • /
    • 2014
  • In ultrasonic medical imaging, spatial compounding of images is a technique where ultrasonic beam is steered to examine patient tissues in multiple angles. In the conventional ultrasonic diagnostic imaging, the steering of the ultrasonic beam is achieved electronically using the phased array transducer elements. In this paper, a spatial compounding approach is presented where the ultrasonic probe element is rotated mechanically and the beam steering is achieved mechanically. In the spatial compounding, target position is computed using the value of the rotation axis and the transducer array angular position. However, in the process of the rotation mechanism construction and the control system there arises the inevitable uncertainties in these values. These geometric parameter errors result in the target position error, and the consequence is a blurry compounded image. In order to reduce these target position errors, we present a spatial compounding scheme where error correcting transformation matrices are computed and applied to the raw images before spatial compounding to reduce the blurriness in the compounded image. The proposed scheme is illustrated using phantom and live scan images of human knee, and it is shown that the blurriness is effectively reduced.

하모닉 영상의 물리학 (Physics of Harmonic Imaging)

  • 최민주;양정화;팽동국
    • 비파괴검사학회지
    • /
    • 제32권5호
    • /
    • pp.564-572
    • /
    • 2012
  • 본 논저에서는 하모닉 영상을 소개하고, 그 원리를 및 물리적 특성을 기존 초음파 영상과 대비하여 기술한다. 인체 조직의 경계에서 반사하는 초음파 에코를 이용한 기존의 초음파 영상의 원리를 제시하고 하모닉 성분을 생성하는 비선형 초음파 전파 과정을 개념적으로 기술한다. 초음파 에코 신호로부터 하모닉 성분을 효율적으로 추출하는 pulse inversion technique를 소개하고 구현된 하모닉 영상이 종래의 초음파 영상과 비교하여 장점을 요약한다. 하모닉의 생성 기전에 따라 하모닉 영상을 분류하고 하모닉 영상을 기존의 초음파 영상과 비교한다. 하모닉 영상의 임상적 중요성, 향후 전망 및 새로운 연구 분야를 언급한다.

공간주파수대역에서 기저대역 확장을 통한 원전 대비시험편과 대비 보정 시험편의 초음파 영상 개선 (Ultrasonic Images Enhancement of the SS Reference Specimen and the Reference Calibration Block for NPPs by the Combining Bases of Support for Spatial Frequency)

  • 박치승;김선진
    • 한국재료학회지
    • /
    • 제13권10호
    • /
    • pp.651-657
    • /
    • 2003
  • Ultrasonic microscope has been used to detect the defects on surface or inner solid. Conventionally, it has used at a single operating frequency. The resolution and quality of the measured images are determined by a characteristic of the transducer of the ultrasonic microscope. The conventional ultrasonic microscope has been used envelope detector to detect the amplitude of reflected signal, but the changes in amplitude is not sensitive enough for specimen with microstructure that in phase. In this paper, we have studied multi-frequency depth resolution enhancement with ultrasonic reflection microscope for the reflectors of a stainless steel reference specimen and a reference calibration block to be used as the material in nuclear power plants for ISI, PSI. Increased depth resolution can be obtained by taking two, three-dimensional images at more that one frequency and numerically combining the results. As results of the experiment, we could get enhanced images with the rate of contrast in proportion and high quality signal distribution for the image to the changing rate of depth for the reflectors of the two kinds of specimens.

3차원 의료기기용 초음파진단기 프로브 개발 (Development of a Ultrasound Probe for 3-D Ultrasonic Imaging)

  • 박종수;김성래;남윤수
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.87-93
    • /
    • 2005
  • Three-dimensional ultrasonic probes being applied to the medical imaging can be grouped into three depending on the scanning methods, which are a mechanical type system, a free-hand system, and 2D phased arrays system. A mechanical type scanner uses a mechanically driven transducer to acquire series of 2D plane images. By integrating these images, a 3-D medical image can be constructed. A motor driving mechanism is a conventional choice for mechanically driving a transducer assembly which picks the raw ultrasonic images up. In this paper we attempt to design a 3D ultrasonic probe which has a operating mechanism of s tilting 3-D scanning. The motion of a transducer assembly of the ultrasonic probe is analytically modelled. We propose a selection procedure for the diameter of a wire rope driving the transducer assembly and the size of torsional spring which gives an initial tension to wire ropes.

  • PDF

Side lobe free medical ultrasonic imaging with application to assessing side lobe suppression filter

  • Jeong, Mok Kun;Kwon, Sung Jae
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.355-364
    • /
    • 2018
  • When focusing using an ultrasonic transducer array, a main lobe is formed in the focal region of an ultrasound field, but side lobes also arise around the focal region due to the leakage. Since the side lobes cannot be completely eliminated in the focusing process, they are responsible for subsequent ultrasound image quality degradation. To improve ultrasound image quality, a signal processing strategy to reduce side lobes is definitely in demand. To this end, quantitative determination of main and side lobes is necessary. We propose a theoretically and actually error-free method of exactly discriminating and separately computing the main lobe and side lobe parts in ultrasound image by computer simulation. We refer to images constructed using the main and side lobe signals as the main and side lobe images, respectively. Since the main and side lobe images exactly represent their main and side lobe components, respectively, they can be used to evaluate ultrasound image quality. Defining the average brightness of the main and side lobe images, the conventional to side lobe image ratio, and the main to side lobe image ratio as image quality metrics, we can evaluate image characteristics in speckle images. The proposed method is also applied in assessing the performance of side lobe suppression filtering. We show that the proposed method may greatly aid in the evaluation of medical ultrasonic images using computer simulations, albeit lacking the use of actual experimental data.

Field Application of an Ultrasonic Testing for Reconstructing CT Images of Wooden Columns

  • Lee, Sang-Joon;Park, Chun-Young;Kim, Kwang-Mo;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제37권2호
    • /
    • pp.148-154
    • /
    • 2009
  • This research examined the applicability of using an ultrasonic test to reconstruct CT images of an ancient wooden building. Most of the columns in the building are severely deteriorated due to termite attacks or the effect of weathering. Ultrasonic CT images of the columns were used to create highly accurate digital reconstructions, despite a lack of the data caused by parts of the building walls being buried. Another semi-NDE technique, a drilling test based on resistography, was applied in order to verify the ultrasonic test results. The discrepancy in detection between two methods is believed to be due to the fundamental differences between two methods. The performance of the ultrasonic test was hindered by poor surface conditions and this technique tended to over-estimate the size of cavities produced by termites or other insects. Nevertheless, the deterioration detected was in many ways congruent with the drilling test results

초음파 진단기의 설정 파라미터가 영상의 질에 미치는 효과 (Effects of Ultrasonic Scanner Setting Parameters on the Quality of Ultrasonic Images)

  • 양정화;이경성;강관석;팽동국;최민주
    • 한국음향학회지
    • /
    • 제27권2호
    • /
    • pp.57-65
    • /
    • 2008
  • 초음파 진단기의 설정은 영상의 질에 영향을 준다. sonographer는 최적의 영상을 얻기 위해 초음파 영상의 질에 영향을 주는 설정 변수에 대한 효과를 이해해야 한다. 본 연구에서는 4가지 대표적인 영상 조절 변수 즉 TGC (Time Gain Control), 이득 (Gain), 주파수 (Frequency), DR (Dynamic Range)를 고려하였다. 초음파 영상의 질은 LCS (Law Contrast Sensitivity) 관점에서 정량적으로 비친 평가하였다. 실험은 임상용 초음파 진단기 (SA-9000 PRIME, Medison, Korea)를 사용하여 초음파 평가 팬텀 (539, ATS, USA)의 LCS 타겟을 영상화하였다. 영상 조절 변수의 설정을 변화하면서, 각 설정에 대한, 6개의 LCS 영상 (+15 dB, +C dB, +3 dB, -3 dB, -6 dB, -15 dB)을 취득하고, 영상에 대한 LCS픽셀 값을 계산하였다. 실험결과 TGC가 최대, Gain은 중간에서 최대사이, 주파수가 Pen모드, DR이 40-66 dB일 때 타겟 영상 (LCS)의 평균 픽셀 값이 높았다. 모든 타겟 영상에서 DR이 40 dB일 때에 LCS가 좋은 영상을 얻었다. 본 결과는 임상에서 잘 발견되는 solid lesion (+15, +6, +3 dB 타겟과 유사) 또는 cystic lesion (-15, -6, -3 dB 타겟과 비슷)이 있는 mass 평가 시 적절한 영상조절 변수 설정에 유용한 정보를 제공할 것으로 기대된다.

초음파 프로브에서 인접 단위 소자군(SAE) 결함이 도플러 영상에 미치는 영향 (Influence to the Doppler Images by the Defects of SAE in the Probe of Medical Ultrasonic Scanners)

  • 이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.7-15
    • /
    • 2015
  • 초음파 진단기에서 프로브는 화질에 차지하는 비중이 크면서도 결함 발생 빈도가 높다. 그러므로 초음파 QA에 있어서는 프로브 관리를 중심으로 수립되어야 한다. 이를 위해서는 초음파 프로브의 성능이나 결함이 초음파 화질에 미치는 영향에 대한 선행 연구가 요구된다. 본 연구는 초음파 프로브 소자의 결함이 도플러 영상에 미치는 영향을 평가하고자 한 것이다. 프로브 소자 결함이 발생하는 여러 유형 중에서 본 연구에서는 동시에 단선된 일정 단위의 인접한 프로브 소자군(a set of adjacent elements: SAE)의 결함이 도플러 영상에 미치는 효과를 평가하였다. 실험 결과를 보면 프로브 소자 결함은 그 크기가 클수록 도플러 활동 소자군 중심부에 위치할수록 도플러 영상의 밝기 및 도플러 속도를 크게 감소시키는 것으로 나타났다. 결함이 증가할수록 도플러 속도와 영상의 밝기의 분산이 더 커지는 것으로 나타났다. 결함 소자의 수와 위치에 따라 스펙트럼에서 강도와 속도는 일치하지 않은 것을 알 수 있었다. 그리고 일정 수준 이상의 프로브 소자의 결함은 도플러 모드에서 활성화 되는 소자군 부근에서 도플러 속도에 영향을 주고 있는 것을 확인할 수 있었다.