• Title/Summary/Keyword: Ultrasonic image

Search Result 414, Processing Time 0.027 seconds

Implementation of An Automated Ultrasonic Flaw Imaging System for the Inspection of Pipe Welding (배관 용접부 자동 초음파 결함 영상 보정 시스템 구현)

  • Kim, Han-Jong;Park, Jong-Hoon;Kim, Cheol-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.556-559
    • /
    • 2008
  • In this study, an automated ultrasonic testing system and post signal and image processing techniques are developed in order to construct ultrasonic flaw images in weldments. The automated ultrasonic testing system developed in the present study adopted an 8 channel pulser/receiver-ADC unit and a 2 axis motion driving unit and the post signal and image processing algorithms are built into the system program of the automated ultrasonic testing system.

  • PDF

3-D Underwater Object Restoration Using Ultrasonic Transducer Fabricated with 1-3 Type Piezoceramic/Polymer Composite and Neural Networks (1-3형 복합압전체로 제작한 초음파 트랜스듀서와 신경회로망을 이용한 3차원 수중 물체복원)

  • Jo, Hyeon-Cheol;Lee, Gi-Seong;Choe, Heon-Il;Sa, Gong-Geon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.6
    • /
    • pp.456-461
    • /
    • 1999
  • In this study, the characteristics of Ultrasonic Transducer fabricated with PZT-Polymer 1-3 type piezoelectric ceramic/polymer composite are investigated. 3-D underwater object restoration using the self-made ultrasonic transducer and modified SCL(Simple Competitive Learning) neural network was presented. The ultrasonic transducer was satisfied with the required condition of commerical ultrasonic transducer in underwater. The modified SCL neural network using the acquired object data $16\times16$ low resolution image was used for object restoration of $32\times32$ high resolution image. The experimental results have shown that the ultrasonic transducer fabricated with PZT-Polymer 1-3 type piezoelectric ceramic/polymer composite could be applied for SONAR system.

  • PDF

Ultrasonic Images Enhancement of the SS Reference Specimen and the Reference Calibration Block for NPPs by the Combining Bases of Support for Spatial Frequency (공간주파수대역에서 기저대역 확장을 통한 원전 대비시험편과 대비 보정 시험편의 초음파 영상 개선)

  • Park, Chi-Seung;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.13 no.10
    • /
    • pp.651-657
    • /
    • 2003
  • Ultrasonic microscope has been used to detect the defects on surface or inner solid. Conventionally, it has used at a single operating frequency. The resolution and quality of the measured images are determined by a characteristic of the transducer of the ultrasonic microscope. The conventional ultrasonic microscope has been used envelope detector to detect the amplitude of reflected signal, but the changes in amplitude is not sensitive enough for specimen with microstructure that in phase. In this paper, we have studied multi-frequency depth resolution enhancement with ultrasonic reflection microscope for the reflectors of a stainless steel reference specimen and a reference calibration block to be used as the material in nuclear power plants for ISI, PSI. Increased depth resolution can be obtained by taking two, three-dimensional images at more that one frequency and numerically combining the results. As results of the experiment, we could get enhanced images with the rate of contrast in proportion and high quality signal distribution for the image to the changing rate of depth for the reflectors of the two kinds of specimens.

Ultrasonic Image Reconstruction using Mode-Converted Rayleigh Wave (파형 변환된 레이리파를 이용한 초음파영상복원)

  • Suh Dong-Man
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.403-408
    • /
    • 1999
  • In this paper, ultrasonic tomography by the Mode-Converted Rayleigh wave (MCRW) in the back-scattered direction is presented. When a beam with a short pulse and narrow beam width enters a reflector with smooth surface, in general, two major arrivals can be observed in the output waveform: the specular reflection and the radiation of the MCRW from the reflector surface. The time-delay between the two waves is relatively large and thus can be measured easily. This large time-delay is due to the fact that the MCRW is slower than incident wave. In our method, this large time- delay is used for ultrasonic image reconstruction. To effectively detect the MCRW, the arrayed-receiving transducers are circularly arranged around the transmitter. In addition, a deconvolution method is employed to remove specular echo signals for reconstructing the MCRW image.

  • PDF

Map-Building for Path-Planning of an Autonomous Mobile Robot Using a Single Ultrasonic Sensor (단일 초음파센서를 이용한 자율 주행 로봇의 경로 계획용 지도작성)

  • Kim, Young-Geun;Kim, HaK-Il
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.12
    • /
    • pp.577-582
    • /
    • 2002
  • The objective of this paper is to produce a weighted graph map for path-planning of an autonomous mobile robot(AMR) based on the measurements from a single ultrasonic sensor, which are acquired when the autonomous mobile robot explores unknown indoor circumstance. The AMR navigates in th unknown space by following the wall and gathers the range data using the ultrasonic sensor, from which the occupancy grid map is constructed by associating the range data with occupancy certainties. Then, the occupancy grid map is converted to a weighted graph map suing morphological image processing and thinning algorithms. the path- planning for autonomous navigation of a mobile robot can be carried out based on the occupancy grid map. These procedures are implemented and tested using an AMR, and primary results are presented in this paper.

A Study on Volume Visualization Method of Three-Dimensional Ultrasonic Medical Image (삼차원 초음파 의료 영상의 입체 묘사 기법 연구)

  • Choi, J.P.;Ha, M.H.;Ra, J.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.45-48
    • /
    • 1995
  • Visualization of three dimensional medical images has been studied in many ways. For CT and MRI data, 3D rendering schemes are commercially available and widly used. However visualization of ultrasonic 3D data is not popular yet, even though its potentional in medical diagnosis seems very high. In this paper we try to visualize 3D ultrasonic data. The basic method is adopted from the volume rendering technique. Based on the characteristics of the ultrasonic images, 3D visualization algorithm is developed and applied for the 3D image set of a dog heart.

  • PDF

Combustion Characteristics According to the Equivalence Ratio of Hydrocarbon Fuel/Air Premixture Excited by Ultrasonic Standing Wave (정상초음파가 인가된 탄화수소계 연료/공기 혼합물의 당량비에 따른 연소특성)

  • Kim, Min Cheol;Bae, Seong Hun;Hong, Joon Yeol;Kim, Jeong Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.628-631
    • /
    • 2017
  • An experimental study of the combustion characteristics according to the equivalence ratio of hydrocarbon fuel/air premixture excited by ultrasonic standing wave are presented. The image of the propagating flame was acquired using a high-speed camera, and the combustion characteristics of each fuel were closely observed through image processing. it was conformed that ultrasonic standing wave has been found to stimulate the combustion reaction in the stoichiometric ratio.

  • PDF

Ultrasonic Cavitation Effect Observation Using Bubble Cloud Image Analysis (기포군 영상분석을 통한 초음파 캐비테이션 현상의 변화 관찰)

  • Noh, Si-Cheol;Kim, Ju-Young;Kim, Jin-Su;Kang, Jung-Hoon;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.124-130
    • /
    • 2011
  • In this study, in order to evaluate the yield of bubble by ultrasonic cavitation in HIFU sonication, the bubble image analysis was performed. The changing phenomenon of cavitation effect according to the sonication condition was discussed by analyzing the bubble image. Especially the appearance of bubble cloud, the size of micro-bubble, and the yield of bubble were considered. The 500 KHz and 1.1 MHz concave type ultrasonic transducers were used for HIFU sonication. Computer controlled digital camera was used to obtain the bubble image, and the binary image processing(binarization coefficient : 0.15) was performed to analyze them. In results of 500 KHz and 1.1 MHz transducer, the area of bubble cloud was increased in proportion to the rise in sonication intensity($R^2$ : 0.7031 and 0.811). The mean size of single microbubble was measured as 98.18 um in 500 KHz sonication, and 63.38 um in 1.1 MHz sonication. In addition, the amount of produced bubble was increased in proportion to sonication intensity. Through the result of this study and further study for variable image processing method, the quantitative evaluation of ultrasonic cavitation effects in HIFU operation could be possible with the linearity associated with the sonication conditions.

A Case Study on Lower Extremity Muscle of Elderly with Osteoarthritis in Ultrasonic Image (초음파영상에서 골관절염을 가진 노인의 하지 근육에 대한 사례연구)

  • Yoon, Se-Won;Park, Soo-Ji;Lee, Jeong-Woo
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.102-106
    • /
    • 2013
  • ■ Objectives The purpose of the this study was to investigate organization change(pennation angle) of lower extremity muscle in elderly with knee osteoarthritis through ultrasonic image. Also, we examined organizational change of muscle was by influenced after total knee replacement(TKR). ■ Methods Rectus femoris image was taken at 50% of the distance between the anterior superior iliac spine and the superior border of the patella. Vastus medialis image was taken at the most distal insertion level of vastus medialis on the medial border of the patella. measurements included the most distal insertion level of the vastus medialis on the medial border of the patella. ■ Results Change of pennation angle in rectus femoris showed decrease from 5.11° in preoperation to 4.29° in 1 week after operation. Change of pennation angle in vastus medialis showed decrease from 6.94° in preoperation to 5.76° in 1 week after operation. ■ Conclusion We consider decrease of pennation angle after total knee replacement in this study was casued by organizational change of muscle and this pennation angle was influenced force created by muscle. Therefore, we thinks that this pennation angle through ultrasonic image will be available to plane individual muscle exercise program and to confirm muscle mass by muscle strength training.

  • PDF

The Construction of Ultrasonic Hologram and the Image Reconstruction Using Computer (초음파 홀로그램의 구성과 컴퓨터 영상재현)

  • Jang, Seong-Hwan;Go, Dae-Sik;Jeon, Gye-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.23-28
    • /
    • 1989
  • In this paper, the construction of ultrasonic hologram and the image reconstruction using computer have been studied, and it has been compared with optical reconstruction. The ultrasonic hologram has been constructed using c-scanning method$(128\times128 step)$and the image of the object has been reconstructed by computer using Rayleigh -Sommerfeld formula and DFT algorithm. In this experiment, the holography system has been builted with the transducer of 5MHz center frequency and 5cm focal length, and the mechanical c-scanning system. It has been shown that the reconstructed image using computer for aluminum plane with the 'S' shaped defect has been displayed image of high quality.

  • PDF