• Title/Summary/Keyword: Ultrasonic frequency

Search Result 907, Processing Time 0.023 seconds

Elastic Modulus Prediction for Design of Sintered Aluminum by Ultrasonic (초음파에 의한 알루미늄 소결체 설계를 위한 탄성계수 예측)

  • Nam, Young-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.7
    • /
    • pp.590-596
    • /
    • 2008
  • The ultrasonic velocities of sintered aluminum with varying density were measured in order to deduce the mechanical properties for optimum design of the sintered aluminum. Specimens with different densities were prepared by the plasma activated sintering machine. The density distribution of sintered aluminum becomes partially inhomogeneous because of the friction between the powder and the die during compaction. The elastic moduli are increased as the ultrasonic velocity is increased. Furthermore, Poisoon's ratio is depending on not only the density but also the size and distribution of voids. As the specimen's thickness increases, the center frequency in the frequency spectrum of the reflection wave is shifted to the low frequency. The attenuation coefficient of ultrasonic wave is decreased inversely as the density increased.

Design of Tool for Food Cutting with Ultrasonic Waves (초음파 식품 컷팅용 공구의 설계)

  • Park, Woo-Yeol;Jang, Ho-Su;Kim, Jung-Ho;Park, Dong-Sam
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.80-85
    • /
    • 2012
  • The ultrasonic cutting method is which cutting by applying high frequency vibrational energy into specific area at constant pressure. Ultrasonic cutting is consisted of power supply, transducer, booster and cutting tool. Precise designing is required since each part's shape, length and mass can affect driving frequency and vibration mode. This paper focused to cutting tool design, its length L was set by calculating vibration equation. And the value of the shape parameter a was diversified as the integral multiple and the result of 40,189Hz the analysis of Modal was shown in the length 30mm of the result of performance b in the 11th mode Also by performing harmonic response analysis, the frequency response result was 40,189Hz, which was similar to modal analysis result.

Frequency Distribution of Mechanical Noise Signals for Ultrasonic Wave and AE Sensor with Brush Spark of DC Motor (직류전동기 브러시 섬락에 따른 기계적 노이즈 신호의 주파수 분포)

  • 이상우;김인식;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.36-43
    • /
    • 2004
  • In this paper, the frequency spectra from respective mechanical noise signals detected using ultrasonic wave and AE(Acoustic Emission) sensor were analysed to under spark generation between brush and commutator side with arbitrarily 15$^{\circ}$ rotation for brush from the DC motor in operation. Also, the frequency spectra from respective magnetizing noise signals detected using ultrasonic wave and AE sensor were analysed to under neutral point for brush from the DC motor in normal operation. And the analyses and comparison between the mechanical noise signal and magnetizing noise signal of ultrasonic wave with brush location change from the DC motor in operation. As the experimental results, tile mechanical noise signal of ultrasonic wave under spark generation between brush and commutator side with brush location change from the DC motor in operation were increased about 2.5∼3.0 times than magnetizing noise signal of ultrasonic wave form the DC motor in normal operation. Also, the main frequency band for mechanical noise signals of AE under spark generation between brush and commutator side with brush location change from the DC motor in operation, appeared about 1.3[MHz]∼l.5[MHz] by the fast fourier transform.

Nondestructive Evaluation for Artificial Degraded Stainless 316 Steel by Time-Frequency Analysis Method

  • Nam, Ki-Woo;Kim, Young-Un
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.3
    • /
    • pp.87-92
    • /
    • 2001
  • In this studies, joint time-frequency analysis techniques were applied to analyze ultrasonic signals in the degraded austenitic 316 stainless steels, to study the evolution of damage in these materials. It was demonstrated that the nonstationary characteristics of ultrasonic signals could be analyzed effectively by these methods. The WVD was more effective for analyzing the attenuation and frequency characteristics of the degraded materials through ultrasonic. It is indicated that the joint time-frequency analysis, WVD method, should also be useful in evaluating various damages and defects in structural members.

  • PDF

A Study on Efficient Frequency Control of Transducer for Skin Treatment Using Multi-Frequency Ultrasound (멀티주파수 초음파를 사용하는 피부 치료기기 트랜스듀서의 효율적인 주파수 제어 연구)

  • Park, Jong-Cheol;Kim, Min-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1038-1048
    • /
    • 2022
  • Ultrasound is one of the effective methods for skin treatment. The skin penetration depth of the ultrasound depends on the ultrasonic frequency, that is, when the ultrasonic frequency is high, the depth is shallow. We have developed a transducer which can generate effectively 3 different ultrasonic frequencies removing interference between 3 types of frequencies according to impedance matching technology. The generated powers of transducer are 40.67W at 3.MHz, 17.46W at 11.7 MHz, and 14.79W at 21.5 MHz. The signal interference between the three frequencies is designed so that they do not interfere with each other by separating the signals using the SPDT (Single Pole, Double Throw) switch. The developed hybrid ultrasound transducer can be applied in skin care or skin treatment and beauty therapy.

Analysis of Contact Resonance Frequency Characteristics for Cantilever of Ultrasonic-AFM Using Finite Element Method (유한요소 해석을 이용한 초음파원자현미경 캔틸레버의 접촉 공진주파수 특성 분석)

  • Lee, Joo Min;Han, You Ha;Kwak, Dong Ryul;Park, Ik Keun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.5
    • /
    • pp.478-484
    • /
    • 2014
  • Ultrasonic atomic force microscopy(Ultrasonic-AFM) can be used to obtain images of the elastic properties of a subsurface and to evaluate the elastic properties by measuring the contact resonance frequency. When a tip is in contact with the sample, it is necessary to understand the cantilever behavior and the tip-sample interaction for the quantitative and reliable analysis. Therefore, precise analysis models that can accurately simulate the tip-sample contact are required; these can serve as good references for predicting the contact resonance frequency. In this study, modal analyses of the first four modes were performed to calculate the contact resonance frequency by using a spring model, and the deformed shapes of the cantilever were visualized at each mode. We presented the contact characteristics of the cantilever with a variety of contact conditions by applying the contact area, contact material thickness, and material properties as the parameters for the FEM analysis.

Observation of Acoustic Characteristic Change in bubble cloud by Ultrasonic Cavitation (초음파 캐비테이션에 의한 기포군에서의 음향특성 변화관찰)

  • Noh, Si-Cheol;Kim, Ju-Young;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.351-356
    • /
    • 2012
  • Ultrasonic cavitation is a physical phenomenon that generates and collapses microbubbles in media (mainly fluids) under conditions of strong ultrasonic irradiation. In this study, changes in the ultrasonic acoustic characteristics of bubble clouds in relation to ultrasonic irradiation were observed by the quantitative evaluation of cavitation yields. Concave-type single ultrasonic transducers with center frequencies of 500 kHz and 1.1 MHz were used to produce cavitation, and 2.25 MHz interference ultrasonic waves that would traverse any bubble clouds generated were used to analyze the cavitation. The parameters used for the evaluation of cavitation yields (changes in the center frequency, attenuation characteristics, and the propagation time of penetrating waves) were analyzed in relation to the cavitation-generating conditions (irradiation intensity, excitation signal, and center frequency). On the basis of these results, correlations between the changes in the center frequency and irradiation intensity were identified. Although the correlation coefficient was low, notable changes were observed in the center frequency under certain irradiation conditions. Attenuation trends in the interference ultrasonic waves showed high correlations with all the irradiation conditions, and it was noted that these trends were not affected by the forms of cavitation generated. No differences in the propagation time were observed among different irradiation conditions. These findings suggest that bubble yields can be quantitatively evaluated effectively by evaluating the diverse irradiation conditions and that such a quantitative evaluation could be used to study the basic cavitation phenomenon occurring in high-intensity ultrasonic wave treatment.

Study on Non-contact Ultrasonic Transducer for Measurement of Fruit Firmness (과실 경도측정을 위한 비접촉 초음파 변환기 연구)

  • Lee, Sang-Dae;Ha, Tae-Hoon;Kim, Ki-Bok;Kim, Man-Soo
    • Journal of Biosystems Engineering
    • /
    • v.35 no.3
    • /
    • pp.189-196
    • /
    • 2010
  • This study was conducted to develop an non-contact ultrasonic transducer for measurement of fruit firmness. The center frequency of non-contact ultrasonic transducer was 500 kHz. As an active element of non-contact ultrasonic transducer, the 1-3 piezoelectric composite material was selected. That material has high piezoelectric properties such as electro-mechanical coupling factor, $k_t$ and piezoelectric voltage constant, $d_{33}$ and also that material has low acoustical impedance which enables to matching the acoustical impedances between piezoelectric material and air. As a front matching material between 1-3 piezoelectric composite material and air, various kinds of paper with different thickness were tested. To control the dead-zone of the fabricated non-contact ultrasonic transducer, the backing material composed of epoxy resin and tungsten powder were made and evaluated. The fabricated non-contact ultrasonic transducer for fruit showed that the cneter frequency, bandwidth and beamwidth were approximately 480 kHz, 30 % and 12 mm, respectively. It was concluded that non-contact measurement of apple firmness would be possible by using the fabricated non-contact ultrasonic transducer.

Ultrasonic Velocity and Absorption Measurements for Polyacrylamide and Water Solutions

  • Bae, Jong-Rim;Kim, Jeong-Koo;Yi, Meyung-Ha
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4E
    • /
    • pp.155-160
    • /
    • 2003
  • Both ultrasonic velocity at 3 MHz and absorption coefficient for the frequency range of 0.2-2 MHz were measured in an aqueous solution of polyacrylamide for the concentration range of 0.5% to 2.5% by weight. Pulse echo overlap method was taken for measuring the ultrasonic velocity over the temperature range of 10-90℃ and the high-Q ultrasonic resonator method was used for the absorption coefficient at 30℃. The velocity exhibited a maximum value at approximately 70℃, 71℃, 72℃, 73℃ and 74℃ in 2.5%, 2.0%, 1.5%, 1.0%, and 0.5% solutions, respectively. The velocity increased with the concentration at a given temperature. The ultrasonic absorption (a/f²) at a given temperature increased linearly with the concentration for the concentration below 1.5%, but suddenly increased for the concentration above 1.5% concentration. The value of a/f² at 1MHz was entirely due to the classical Stoke's viscous effect. The ultrasonic relaxation in polyacrylamide aqueous solutions, which may be the result of structural fluctuations of polymer molecules such as the segmental motion of the polymer chains, was observed, and at 2.5%, the value of a/f² was found to suddenly increase as frequency decreased.

초음파 Spectroscopy에 의한 Resin내의 크기 측정에 관한 연구

  • 한응교;김용재;이범성;박익근;소반신부
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.139-143
    • /
    • 2001
  • In manufacturing process of semiconductor package, thermal stress owing to high temperature in moulding and bubbles generated in chip bonding process become main causes to producing void. Therefore, on this study we evaluated quantitatively void size by ultrasonic spectroscopy method which analyze the frequency of this received pulse using pulses with broad band frequency, and after destructive test we verified effectiveness of sizing void by ultrasonic spectroscopy as we find error degree between the real size of void and the sizing void by ultrasonic spectroscopy.