• Title/Summary/Keyword: Ultrasonic force

Search Result 210, Processing Time 0.026 seconds

Charge-discharge Characteristics of $TiO_2$-Activated Carbon Composite Electrode using Electrospinning (전기방사법으로부터 제조된 $TiO_2$ 섬유 복합전극의 충방전 특성)

  • An, Mi-Sun;Kim, Han-Joo;Son, Won-Keun;Takahashi, Hideaki;Park, Soo-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2022-2024
    • /
    • 2005
  • Electrical double-layer capacitor (EDLC) is an electrochemical energy storage device in which electric charges only accumulated by a pure electrostatic attraction force are stored on the electrolyte-electrode interface in a form of double layer and separated by the electrolyte. The composite was prepared by mixing nanosize $TiO_2$ and activated carbon through a means of ultrasonic vibration in ethanol solution for 30 min in various mass ratios of $AC:TiO_2$ to form activated carbone-semiconducting oxide composites. Either 1.0 M $LiClO_4/EC-DEC$ or $Et_4NBF_4$/EC-DEC was used as the electrolyte. It was found that with modification of $TiO_2$, the specific capacitance of activated carbon measured at $1mA/cm^2$ was increased from 40 to 50 F/g. This method is unique in comparison the conventional method because it uses semiconducting TiO2 other than electrochemically active materials such as $RuO_2$. The increase in specific capacitance could be attributed to the decrease in electric polarization, caused by the introduction of $RuO_2$.

  • PDF

산화아연 압전 나노전력발전소자 기반 에너지 하베스팅

  • Kim, Sang-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.49-49
    • /
    • 2010
  • Nanopiezotronics is an emerging area of nanotechnology with a variety of applications that include piezoelectric field-effect transistors and diodes, self-powered nanogenerators and biosystems, and wireless nano/biosensors. By exploiting coupled piezoelectric and semiconducting characteristics, it is possible for nanowires, nanobelts, or nanorods to generate rectifying current and potential under external mechanical energies such as body movement (handling, winding, pushing, and bending) and muscle stretching, vibrations (acoustic and ultrasonic waves), and hydraulic forces (body fluid and blood flow). Fully transparent, flexible (TF) nanogenerators that are operated by external mechanical forces will be presented. By controlling the density of the seed layer for ZnO nanorod growth, transparent ZnO nanorod arrays were grown on ITO/PES films, and a TF conductive electrode was stacked on the ZnO nanorods. The resulting integrated TF nanodevice (having transparency exceeding 70 %) generated a noticeable current when it was pushed by application of an external load. The output current density was clearly dependent on the force applied. Furthermore, the output current density depended strongly on the morphology and the work function of the top electrode. ZnO nanorod-based nanogenerators with a PdAu, ITO, CNT, and graphene top electrodes gave output current densities of approximately $1-10\;uA/cm^2$ at a load of 0.9 kgf. Our results suggest that our TF nanogenerators are suitable for self-powered TF device applications such as flexible self-powered touch sensors, wearable artificial skins, fully rollable display mobile devices, and battery supplements for wearable cellular phones.

  • PDF

Medical Ultrasonic Elasticity Imaging Techniques (의료용 초음파탄성영상법)

  • Jeong, Mok-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.573-584
    • /
    • 2012
  • Breast and prostate tumors or cancers tend to be stiffer than the surrounding normal tissue. However, the difference in echogenicity between cancerous and normal tissues is not clearly distinguishable in ultrasound B-mode imaging. Thus, imaging the stiffness contrast between the two different tissue types helps to diagnose lesions quantitatively, and such a method of imaging the elasticity of human tissue is termed ultrasound elasticity imaging. Recently, elasticity imaging has become an effective complementary diagnostic modality along with ultrasound B-mode imaging. This paper presents various elasticity imaging methods that have been reported up to now and describes their characteristics and principles of operation.

Effects of various prophylactic procedures on titanium surfaces and biofilm formation

  • Di Salle, Anna;Spagnuolo, Gianrico;Conte, Raffaele;Procino, Alfredo;Peluso, Gianfranco;Rengo, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.6
    • /
    • pp.373-382
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effects of various prophylactic treatments of titanium implants on bacterial biofilm formation, correlating surface modifications with the biofilms produced by Pseudomonas aeruginosa PAO1, Staphylococcus aureus, and bacteria isolated from saliva. Methods: Pure titanium disks were treated with various prophylactic procedures, and atomic force microscopy (AFM) was used to determine the degree to which surface roughness was modified. To evaluate antibiofilm activity, we used P. aeruginosa PAO1, S. aureus, and saliva-isolated Streptococcus spp., Bacteroides fragilis, and Staphylococcus epidermidis. Results: AFM showed that the surface roughness increased after using the air-polishing device and ultrasonic scaler, while a significant reduction was observed after using a curette or polishing with Detartrine ZTM (DZ) abrasive paste. In addition, we only observed a significant (P<0.01) reduction in biofilm formation on the DZ-treated implant surfaces. Conclusion: In this study, both AFM and antibiofilm analyses indicated that using DZ abrasive paste could be considered as the prophylactic procedure of choice for managing peri-implant lesions and for therapy-resistant cases of periodontitis.

A Study on the Electromyography Change for Analysis of rectus femoris muscle stiffness with muscle fatigues (근피로에 의한 하지 대퇴직근의 경직도 분석을 위한 근전도 변화에 관한 연구)

  • Lee, Gyoun-Jung;Nam, Jea-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2317-2323
    • /
    • 2010
  • When the muscle is contracted by continuous and same, the force takes fatigue and stiffness. The aim of this study was to know how the fatigue and muscle stiffness change during an isometric contraction. Surface Electro myography(EMG) signal monitoring system and ultrasonic transducer set up the same muscle stem, subjects contract his right femoris muscle by submaximal isometric contraction(50% of MVC) until exhaustion. Before and after the test, muscle stiffness was measured and EMG was measured during the contraction. As time goes by, muscle fatigue was increased. and the stiffness was shown strongly after the contraction. These results show if the muscle becomes more and more fatigued, the circulation of muscle is delayed although the contraction doesn't happen. So muscle stiffness is increased.

The Study on the Temperature Compensation of Ultrasonic Motor for Robot Actuator Using Fuzzy Controller (퍼지제어기를 이용한 로보트 액츄에이터용 초음파 모터의 온도 보상에 관한 연구)

  • 차인수;유권종;백형래;김영동
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.165-172
    • /
    • 1998
  • The electromechanical energy conversion conditioning and processing implementation in USM direct motion control system is generally divided into two power stages: the two-phase high-frequency ac power inversion stage for driving piezoelectric ceramic PZT transducer array off the USM stator and the mechanical thrust power conversion stage based on the frictional force between the piezo electric stator array and the rotary slider of the USM. However, the dynamic and steady-state mathematical modeling of the USM is extremely default from a theoretical point of view because it contains many complicated an nonlinear characteristics dependant on operation temperature. In +2$0^{\circ}C$~3$0^{\circ}C$, the operating characteristics of the USM has represented normal condition. But the other temperature, it has abnormal condition so that driving frequency, current and motor speed will be down. The recent USM has controller without temperature compensation. This study represents the fuzzy controller for speed compensation according to operating temperature by driving frequency.

Tactile Navigation System using a Haptic Device (햅틱 디바이스를 이용한 촉감형 네비게이션 시스템)

  • Lee, Dong-Hyuk;Noh, Kyung-Wook;Kang, Sun Kyun;Kim, Hyun Woo;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.807-814
    • /
    • 2014
  • In this paper, we proposed a haptic navigation system which used the tactile data for the user guides of the mobile robot to the reference point via tele-operation in unknown blind environment. This navigation system can enable a mobile robot to avoid obstacles and move to the reference point, according to the direction provided by the device guides through a haptic device consisting of a vibration motor in a blind environment. There are a great deal of obstacles in real environments, and so mobile robots can avoid obstacles by recognizing the exact position of each obstacle through the superposition of an ultrasonic sensor. The navigation system determines the direction of obstacle avoidance through an avoidance algorithm that uses virtual impedance, and lets users know the position of obstacles and the direction of the avoidance through the haptic device consisting of 5 vibration motors. By letting users know intuitionally, it lets the mobile robot precisely reach the reference point in unknown blind environment. This haptic device can implement a haptic navigation system through the tactile sensor data.

Walking Aid System for Visually Impaired People by Exploiting Touch-based Interface (촉각 인터페이스를 이용한 시각장애인 보행보조 시스템)

  • Lee, Ji-eun;Oh, Yoosoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.522-525
    • /
    • 2015
  • In this paper, we propose a walking aid system that guides route to visually impaired people in order to recognize uncertain obstacles based on tactile stimulation. The proposed system is composed of the touch-based obstacle detection module, the obstacle height detection module, and the route guidance algorithms. The touch-based obstacle detection module detects each obstacle, which is located at left, right, and front of a visually impaired person by stimulating his thumb with the rotational force of the servomotor. The obstacle height detection module integrates detected data by the linear arrangement of ultrasonic sensors to identify the height of an obstacle about 3 of-phase(i.e., high, medium, low). The proposed route guidance algorithm guides an optimized path to the visually impaired person by updating his current position information based on the signal of the built-in GPS receiver in smartphone. In addition, the route guidance algorithm delivers information with speech to a visually impaired person through Bluetooth commuination in the developed route guidance app. The proposed system can create a path to avoid the obstacles by recognizing the placed situation of the obstacles with exploring the uncertain path.

  • PDF

Improvement effect of formula containing Vitamin A and Vitamin E on the Strech mark (VitaminA와 VitaminE 함유 제제의 Strech mark 개선효과)

  • Kim, Yang-Ho
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.2 no.3 s.3
    • /
    • pp.36-43
    • /
    • 2004
  • This is a research on the effect of formula containing of vitamin A and vitamin E(Frie of oil, Wlter Bouhon GmBH, Germany) on the strech mark. The participants of this study were 20 women at the age of early 20s through middle 20s, who had strech marks that had been over 1 year at the minimum and at less than 5 years at the maximum. Formula containing of vitamin A and vitamin E was applied with typical massage to strech marks for 4 months and twice per day. Improvement resulting from the application was evaluated through observation with the naked eye, questionnaire survey, and the equipment used was DermaScan C Ver3(Cortex Technology, Denmark). The experiment showed that parts cared with formula containing of vitamin A and vitamin E had less strech marks than those control site(treated with jojoba oil).In around 2 months since the use of the formula containing of vitamin A and vitamin E, the tensile of the skin increased and deep wrinkles on the chapped surface became unclear, and in around 4 months the tensile force again decreased and the resilience of the skin increased, and the ultrasonic image showed the decrease of echo pore-zone, which indicates the degree of tissue damage. According to the result of the questionnaire survey, strech marks of less than red strech marks of primary stage were improved more quickly than white strech marks and all participants appeared to experience improvement. The result shows that if this formula is used continuously over 4 months, it reduces strech marks and increase the resilience of the skin. It is considered necessary to continue objective measuring and research concerning strech marks.

  • PDF

Sensing Technologies for Grain Crop Yield Monitoring Systems: A Review

  • Chung, Sun-Ok;Choi, Moon-Chan;Lee, Kyu-Ho;Kim, Yong-Joo;Hong, Soon-Jung;Li, Minzan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.408-417
    • /
    • 2016
  • Purpose: Yield monitoring systems are an essential component of precision agriculture. They indicate the spatial variability of crop yield in fields, and have become an important factor in modern harvesters. The objective of this paper was to review research trends related to yield monitoring sensors for grain crops. Methods: The literature was reviewed for research on the major sensing components of grain yield monitoring systems. These major components included grain flow sensors, moisture content sensors, and cutting width sensors. Sensors were classified by sensing principle and type, and their performance was also reviewed. Results: The main targeted harvesting grain crops were rice, wheat, corn, barley, and grain sorghum. Grain flow sensors were classified into mass flow and volume flow methods. Mass flow sensors were mounted primarily at the clean grain elevator head or under the grain tank, and volume flow sensors were mounted at the head or in the middle of the elevator. Mass flow methods used weighing, force impact, and radiometric approaches, some of which resulted in measurement error levels lower than 5% ($R^2=0.99$). Volume flow methods included paddle wheel type and optical type, and in the best cases produced error levels lower than 3%. Grain moisture content sensing was in many cases achieved using capacitive modules. In some cases, errors were lower than 1%. Cutting width was measured by ultrasonic distance sensors mounted at both sides of the header dividers, and the errors were in some cases lower than 5%. Conclusions: The design and fabrication of an integrated yield monitoring system for a target crop would be affected by the selection of a sensing approach, as well as the layout and mounting of the sensors. For accurate estimation of yield, signal processing and correction measures should be also implemented.