• 제목/요약/키워드: Ultrasonic file

검색결과 25건 처리시간 0.027초

The effect of ultrasonic file sizes on smear layer removal in passive ultrasonic irrigation

  • Kang, Hye-Ju;Jung, Sera;Cho, Ara;Park, Mi-Gon;Jo, Hyoung-Hoon
    • 대한치과의사협회지
    • /
    • 제58권5호
    • /
    • pp.276-283
    • /
    • 2020
  • Objectives: The aim of this study was to evaluate the efficacy of CK files as an ultrasonic instrument, and to determine most efficient file size for smear layer removal. Materials and Methods: Thirty-six extracted human mandibular premolars with single, straight root canals and mature apices were mechanically prepared and randomly divided into three groups. Group 1 (Control) underwent conventional needle irrigation, Group 2 (CKS) underwent passive ultrasonic irrigation with a #20 CK file, and Group 3 (CKL) underwent passive ultrasonic irrigation with a #30 CK file. After preparation and irrigation, all teeth were dried and split with a chisel to obtain the mesial and distal half of their roots. Each sample was evaluated using a scanning electron microscope, and data were analyzed using the Kruskal-Wallis and Mann-Whitney rank sum tests (p<0.05). Results: The CKS group showed less debris in the apical third than the other groups (p<0.05). In this section, no significant difference was observed among the other groups. And, there was no significant difference among any groups for the middle third section. Conclusion: This study showed that PUI with #20 CK file removed more smear layer compared to using #30 CK file at the apical third of the root canal.

  • PDF

K-File과 초음파기구의 근관확대 및 세척효과에 대한 비교연구 (A COMPARATIVE STUDY OF THE EFFECT K - FILE AND ULTRASONIC INSTRUMENT IN CLEANING AND SHAPING ROOT CANAL)

  • 김상섭;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.413-420
    • /
    • 1992
  • The purpose of this study was to compare the effectiveness of hand instrumentation with K - file and ultrasonic instrumentation and irrigation system in removing pulpal debris and canal wall planing. 20 mandibular molar teeth were instrumented to size 30 K - file and 20 teeth were instrumented with ultrasonic Suprasson. And Normal Saline and 2.5% NaOCl were used as irrigation solution. All specimens were viewed at the coronal, middle, and apical third of the root canals for the evaluation of the cleaning effect under the multiview microscope. The result were as follows : 1. All of the technique and irrigation solution was effecient in the debris removal and canal wall planing at the cervical and middle thirds of the root canal. 2. All of the techniques and irrigation solutions was less efficient in the debris removal and canal planing at the apical third of the root canal. 3. The debris removal and canal wall planing was depended more on the anatomical variations of the root canal than on the techniques and irrigation solutions.

  • PDF

K-FILE과 초음파 기구의 도말층제거효과에 대한 주사전자 현미경적 연구 (A SCANNING ELECTRON MICROSCOPIC STUDY ON THE REMOVING EFFICIENCY OF SMEAR LAYER BY K-FILE AND ULTRASONIC INSTRUMENT)

  • 이수종;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.97-105
    • /
    • 1994
  • The purpose of this study was to evaluate the smear layer removing efficiency of two root canal preparation techniques. Twelve single-rooted teeth were used in two groups of six each. Group 1 was biomechanically prepared by hand using a K-file with a high volume of normal saline irrigation. Group 2 was. prepared by using ultrasonically activated K-file with a constant high volume of normal saline irrigation. After the experimental procedures, each root was split saggitally. The removing efficiency of the preparation methods were assessed in terms of surface condition of the canal walls at three levels, those coronal, middle, and apical thirds. On the basis of remaining debris, presence of smear layer, and patency of dentinal tubules, each canal was evaluated according to a scale form 0 to 2. A statistical analysis was used to indicated any significant differences in surface condition between the two methods. There was no statistical significance between hand instrumentation and ultrasonic instrumentation at the cervical third but removing efficiency of ultrasonic instrumentation was superior. No statistically significant differences were obhserved for middle or apical third.

  • PDF

근관 내 불규칙 확장부에서 sealer 적용방법에 따른 충전 효과 평가 (AN IN-VITRO EVALUATION OF SEALER PLACEMENT METHODS IN SIMULATED ROOT CANAL EXTENSIONS)

  • 김성용;이미정;문장원;이세준;유미경
    • Restorative Dentistry and Endodontics
    • /
    • 제30권1호
    • /
    • pp.31-37
    • /
    • 2005
  • 본 실험은 resin 시편을 이용하여 미리 제작한 근관 내 불규칙 확장부에서 근관 충전용 sealer의 적용 방법에 따른 충전 효과를 평가해 보았다. Endo-training Bloc을 절단하여 사십 개의 규격화된 resin 블록 시편을 획득하였다. 각각의 시편에 $\#20$, 08taper GT 파일을 사용하여 근관을 형성하였고 근관에 손상이 가지 않도록 시편을 양분한 후 양분된 시편의 한 쪽 근관 벽에 다양한 근관 내 확장부를 표현하는 구를 형성하였다. 양분된 시편을 결찰하고 절단 부위를 밀봉하였으며 AH26 sealer를 사용하여 단일 cone 충전법으로 근관을 충전하였다. 네 가지의 근관 충전용 sealer의 적용방법을 이용하였다: A군, $\#20$ K-file : B군, ultrasonic file : C군, lentulo spiral: D군. EZ-Fill bi-directioanl spiral. 모든 시편은 $37^{\circ}\;100\%$ 상대습도에서 1주일간 보관한 후 각 시편을 근단에서 3mm, 4mm, 5mm 부위에서 수평으로 절단하고 각각의 절단면을 위상차현미경과 디지털 카메라를 이용하여 30배율로 관찰하고 촬영하였다. 관찰된 절단면은 scoring system을 이용하여 점수를 산정하였고 각 군 간의 통계적인 유의성 유무는 Fisher's Exact Test를 이용하여 시행하였다.

초음파 근관치료기기의 절삭 및 근관 성형능력에 관한 실험적 연구 (An Experimental Study on the Cutting and Canal Shaping Ability of the Ultrasonic Devices)

  • 노병덕;이승종;박동수;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제13권1호
    • /
    • pp.91-101
    • /
    • 1988
  • The purpose of this study was to evaluate Ultrasonic devices in root canal enlargement, about the effects on the canal shape and on the cutting ability beyond the curvature in curved canals. 180 resin blocks with $40^{\circ}$ curvature in apical third and 16mm long canal were made of epoxy resin and smooth broaches. These blocks were devided into six groups. According to the devices (ENAC$^{(R)}$, HARMOSONIC$^{(R)}$, Sonic Air MM 3000$^{(R)}$) and files (Zipperer file, H-file, Flexofile, K-file, Sharper file), five groups were instrumented one minute with # 15 files, then the enlarged size was measured. And # 20 files were used again in the same groups, then the enlarged size was measured. In control group, the time which was taken to enlarge the canal from # 15 to # 20 by hand technique was measured. The data was analyzed statistically. Then the enlarged shapes were evaluated in six groups with the stereomicroscope and recorded in ideal and non-ideal canal shape to compare the effects of ultrasonic devices on the canal shape. Only the ideal shaped canals were used in the study whether the cutting ability beyond the curvature in curved canals was, or not. The files with whole flutes, no flutes, and flutes in apical 5mm only were used. The weight differences of pre-and post-instrumentation by Sonic Air MM 3000$^{(R)}$ for two minutes were compared. The results were as follow: 1. Intracanal instrumentation for 1 minute with ultrasonic devices using # 15 and # 20 file in curved root canal of the epoxy resin block can not reach to the next file size. 2. Sonic Air MM 3000$^{(R)}$ shows higher cutting ability than the other two devices (p=0.001), however the percentage of non-ideal canal shape was the highest. 3. Two ultrasonic devices except Sonic Air MM 3000 considered normal in ideal canal shaping ability. 4. little cutting ability was shown beyond the curvature of curved canals.

  • PDF

근관 내 File의 파절 시 대처 방안 (MANAGEMENT OF SEPARATED FILE IN THE ROOT CANAL)

  • 김혜정;장훈상;박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제31권3호
    • /
    • pp.161-168
    • /
    • 2006
  • 근관형성을 하는 과정에서 기구가 파절될 가능성은 언제나 존재한다. File을 비롯하여 lentulo spiral, Gates-Glidden (GG) bur 또는 여타의 이물질도 근관 내에 남겨질 수 있다. 근래에는 수동 file에 비해 많은 장점을 가지고 있는 회전식 nickel-titanium (NiTi) file의 사용이 보편화 되고 있으나 기구의 높은 파절 경향이 문제가 되고 있다. NiTi file의 파절은 매우 빠른 시간내에 일어나고 예측이 불가능하며 임상가에게 정신적 stress를 가져다. 주기 때문에 임상가로 하여금 niTi file의 사용을 주저하게 만들기도 한다. 근관 내 기구가 파절되면 제거하는 것이 가장 최선의 해결 방법이다. 초음파 기기와 미세 현미경의 사용으로 파절된 기구의 제거율이 높아지고 있지만 제거하는 것이 쉬운 일만은 아니며 항상 제거가 가능한 것도 아니다. 그러므로 예방이 최선의 방법이라 할 수 있다. 본 증례에서는 근관 내 file이 파절된 경우에 있어 여러 가지 대처 방안에 대해 보고하고자 한다.

Comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit for the removal of separated endodontic instruments

  • Pruthi, Preeti Jain;Nawal, Ruchika Roongta;Talwar, Sangeeta;Verma, Mahesh
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.14.1-14.7
    • /
    • 2020
  • Objective: The aim of this study was to perform a comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit (TFRK) for the removal of broken endodontic instruments. Materials and Methods: A total of 80 extracted human first mandibular molars with moderate root canal curvature were selected. Following access cavity preparation canal patency was established with a size 10/15 K-file in the mesiobuccal canals of all teeth. The teeth were divided into 2 groups of 40 teeth each: the P group (ProUltra tips) and the T group (TFRK). Each group was further subdivided into 2 smaller groups of 20 teeth each according to whether ProTaper F1 rotary instruments were fractured in either the coronal third (C constituting the PC and TC groups) or the middle third (M constituting the PM and TM groups). Instrument retrieval was performed using either ProUltra tips or the TFRK. Results: The overall success rate at removing the separated instrument was 90% in group P and 95% in group T (p > 0.05) The mean time for instrument removal was higher with the ultrasonic tips than with the TFRK (p > 0.05). Conclusion: Both systems are acceptable clinical tools for instrument retrieval but the loop device in the TFRK requires slightly more dexterity than is needed for the ProUltra tips.

각종 근관충전법의 치근단 폐쇄효과에 관한 연구 (AN EXPERIMENTAL STUDY ON THE SEALING ABILITY OF DIFFERENT ROOT CANAL OBTURATION METHODS)

  • 허승면;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.143-154
    • /
    • 1991
  • The purpose of this study was to evaluate the sealing ability of five obturation methods in conjunction with sealer. Fifty extracted upper and lower anterior teeth were selected and the access cavities were prepared lingually with a round bur. The working length was determined with a #15K file, and the root canals were instrumented with a #40K file 1mm short of the apical foramen. The apical third of root canal was flared by step-back technique and the coronal two thirds of root canal using #2 - 3 Gates Glidden drills. And then, the teeth were randomly assigned to five groups of 10 teeth each. A thin coat of Tubliseal was placed into the canal into the canal using the # 35 reamer and the canals were filled by lateral condensation, vertical condensation, ultrasonic activated lateral condensation, ULTRAFIL injecting, and McSpadden compaction methods. All teeth were stored in 100 % relative humidity at 31c for 48 hours. The roots were suspended in 2 % methylene blue solution for 48 hours, left to dry for 24 hours and then, half side of root was removed longitudinally using the fissure bur. A Boley gauge wes used to measure the distance, to the nearest 0.1mm, from the apical foramen to the most coronal level of dye penetration. The measurement of dye penetration was statistically compared by Duncan's multiple range test The results were as follows 1. Ultrasonic group showed the best sealing ability among the all experimental groups, but there were statistically no significant difference in the sealing ability between ultrasonic group and vertical condensation group. 2. There were no statistically significant difference in the sealing ability among the lateral, vertical, and ultrasonic groups. 3. McSpadden group showed the worst sealing ability among the all exprimental groups.

  • PDF

An in-vitro evaluation of sealer placement methods in simulated root canal extensions

  • Kim, Sung-Young;Lee, Se-Jun;Lee, Kwang-Won
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.579-579
    • /
    • 2003
  • I. Objectives The aim of this study was to evaluate and compare the effectiveness of sealer placement in simulated root canal extensions using the K file, ultrasonic file, lentulo spiral and EZ-Fill. II. Materials and Methods Forty resin blocks were attained from cutting Endo-training Bloc with diamond saw. In each parallelepiped block, the simulated root canal was made with #20, 08taper GT file. After each block was longitudinally split into two halves using mallet and chisel, a standardized groove of 4mm in length, located 2mmapart from the root apex, was prepared on one wall of two halves using the custom-made knife to simulate the canal extensions with various irregularities.(omitted)

  • PDF