• Title/Summary/Keyword: Ultrasonic dependence

Search Result 54, Processing Time 0.024 seconds

The properties of ZnO/MgO films prepared by ultrasonic spray pyrolysis (초음파분무법으로 제조한 ZnO/MgO막의 특성)

  • Choi, Mu-Hee;Ma, Tae-Young
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.362-367
    • /
    • 2005
  • ZnO films were deposited on MgO substrates (ZnO/MgO) by ultrasonic spray pyrolysis. Substrate temperature varied from $250^{\circ}C$ to $350^{\circ}C$. The crystallographic properties and surface morphologies of the ZnO/MgO films were studied by X-ray diffraction and scanning electron microscopy. The properties of photoluminescence (PL) for the films were investigated by dependence of PL spectra on the substrate temperature and the annealing temperature. The ZnO/MgO films prepared at $350^{\circ}C$ showed the strongest Ultraviolet light emission peak at 18 K and 300 K among the films in this study. The annealing process increases the visible light emission, which is due to the increased oxygen vacancies.

UV emission of ZnO:Er films prepared by ultrasonic spray pyrolysis (초음파분무법으로 제조한 ZnO:Er막의 UV 발광 특성)

  • Choi, Mu-Hee;Ma, Tae-Young
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.307-312
    • /
    • 2007
  • The films of Er-doped ZnO (ZnO:Er) were prepared onto MgO wafers by ultrasonic spray pyrolysis at $550^{\circ}C$. The concentration of Er in the deposition source varied from 0.5 wt% to 3.0 wt%. The crystallographic properties and surface morphologies of the films were investigated by X-ray diffraction (XRD) and scanning electron microscope (SEM), respectively. The properties of photoluminescence (PL) for the films were investigated by dependence of PL spectra on the Er concentration in the films. The films were grown as polycrystalline with a dominant direction of [002]. The grain size of the films were reduced by Er-doping. Er-doping enhanced the ultraviolet emission of ZnO:Er films. The ZnO:Er films prepared with the deposition source of 2.0 wt% Er showed the strongest ultraviolet light emission peak among the films in this study.

Enantioseparation by Sonochromatography

  • Ryoo, Jae-Jeong;Song, Young-Ae;Jeong, Young Han;Hyun, Myung-Ho;Park, Jung-Hag;Lee, Won-jae
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.637-641
    • /
    • 2006
  • Although chiral separation has been one of the main topics of chromatographic practice for over twenty-five years, it still presents many difficulties. In this work, the ultrasonic dependence of chiral resolution was investigated at various temperatures to improve resolution and reduce analysis time. The chiral resolution was performed on recently commercialized two HPLC chiral stationary phases (CSP 1 and CSP 2) with the analogues of racemic N-acylnaphthylethylamines (1a-d) and racemic amino acid derivatives (2a-c, 3a-c) as analytes. The CSP 1 was prepared from a (R)-N-(3,5-dinitrobenzoyl)phenylglycinol and the CSP 2 was prepared from a (S)-N-3,5-(dinitrobenzoyl) leucine. From the comparison of the chromatographic results under sonic condition with those under non-sonic condition, we found that the ultrasound decreased the elution time in chiral chromatography at all temperatures and improved the enantioselectivity at high temperature (45, 50, 60 ${^{\circ}C}$).

Ultrasonic Backward Radiation on Randomly Rough Surface (무작위로 거친 표면에서의 후방복사 초음파)

  • Kwon, Sung-D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2005
  • The angular dependence(profile) of backward radiated ultrasound was measured for glass specimens with random surface roughness using ultrasonic goniometer that ran changes the incident angle continuously. It was concluded that the roughened region had greater acoustic impedance than the unperturbed region. The comparison of backward radiations showed that the amplitude of peak and the area of radiation profile were increased with surface roughness. It was suggested from the sensitive dependence of the profile area that the profile of backward radiation could be applied to in the nondestructive evaluation of sulfate region. Inclined C-scan technique with the transducer inclined at Rayleigh angle showed the reverse of luminosity and the high signal to noise ratio so that it provided high resolution.

Study on the Dependence of Ultrasonic Phase Velocity on Porosity, Frequency and Propagation Angle in Cancellous Bone (해면질골에서 다공율, 주파수 및 전파각에 대한 초음파 위상속도의 의존성 연구)

  • Lee, Kang-Il;Kim, Yong-Tae;Choi, Min-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.112-118
    • /
    • 2008
  • In the present study, the dependence of ultrasonic phase velocity on porosity and frequency in cancellous bone was predicted using the Biot model and the modified Biot-Attenborough (MBA) model for propagation in fluid-saturated porous media. It was also compared with previously published measurements in human and bovine cancellous bones in vitro. It was shown that the phase velocity in cancellous bone decreased with increasing porosity and frequency The dependence of phase velocity on propagation angle in cancellous bone as predicted using the Schoenberg model together with the Biot model and tile MBA model which were modified to include the effect of angle. The theoretical models used in the present study advance our understanding of the interaction between ultrasound and cancellous bone and can be expected to be usefully employed for the diagnosis of osteoporosis.

Comparison of the Model-predicted and Measured Target Strength of Cuttlebones from Golden Cuttlefish Sepia esculenta (갑오징어의 갑에 대한 모델 예측과 측정 반사강도의 비교)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.2
    • /
    • pp.209-217
    • /
    • 2020
  • The purpose of this study was to compare the model-predicted and experimentally measured target strength (TS) of golden cuttlefish Sepia esculenta cuttlebones. Ultrasonic signals used to estimate frequency-dependent TS and the speed of sound in cuttlebones were measured by pulse-echo and through-transmission techniques, using a chirp sonar system and an ultrasonic pulser/receiver system under controlled laboratory conditions. The model appeared to slightly underestimate the predicted TS values in the frequency range of 100-160 kHz. However, there was good agreement between the predicted and measured TS values in the frequency range of 160-200 kHz. The significant similarity between the model-predicted and experimentally measured TS values supports the use of the Kirchhoff-ray mode (KRM) model for acoustic scattering analysis of cuttlebones. Accordingly, we concluded that the KRM model can be used as a tool to evaluate the frequency-dependent variability of TS due to changes in golden cuttlefish swimming depth.

A Study on Spectral Characteristics of Ultrasonic Signal for Tissue Attennation Coefficient Measurement (생체내의 초음파 감쇄계수를 측정하기 위한 초음파 신호스펙트럼 특성에 관한 연구)

  • Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.29-36
    • /
    • 1983
  • In this paper, center frequency down slift of ultrasonic echo signals which for the measurements of frequency dependent attenuation in the biological tissue are estimated. Center frequency down shift of echo-signals are estimated after signal spectrum analysis of whole echo-signals. In case of signal spectrums are simple, estimation of down shift frequency is very simple and in case of complicate spectrum, estimation of down shift frequency is depend on spectral shape. In case of unable to estimate, frequency dependence of medium is nonlinear(n) 1), in which upper shift of spectrums are presented. In case of unable to estimate, spectrum analysis are performed at local position. At consquence, we know that spectral dispersions are caused complicately by biological tissue layer.

  • PDF

Preparation of $BaTiO_3$ Fine Powders by Spray Pyrolysis Using Ultrasonic Atomization Technique (초음파 분무 열분해법에 의한 $BaTiO_3$ 미분말의 제조)

  • 조형진;이종흔;박순자
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.11
    • /
    • pp.851-858
    • /
    • 1991
  • Spherical fine BaTiO3 powders with an average diameter of 0.3${\mu}{\textrm}{m}$ to 0.9${\mu}{\textrm}{m}$ are prepared at 100$0^{\circ}C$ by the ultrasonic spray pyrolysis of solutions containing Ba(NO3)2 and TiCl4. Experimental variables are adjusted to produce BaTiO3 powders and its effect on the phase, the size and the morphology of the particles are investigated by XRD, SEM, TEM. Each particle consists of small primary particles and has a hollow around its center. The dependence of particle diameters on the concentrations of source solutions indicates that metal salt precursors are dried to precipitate solid particles and decompose to form BaTiO3 phase without gas phase reactions.

  • PDF

Nondestructive Evaluation for Degraded 2.25Cr-1Mo Steel though Surface SH-wave (표면SH파를 이용한 2.25Cr-1Mo강의 열화.손상 평가)

  • Kim, Hyun-Mook;Park, Ik-Keun;Park, Un-Su;Ahn, Hyung-Keun;Kim, Chung-Soek
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.280-285
    • /
    • 2000
  • It is very important to evaluate the surface or subsurface microstructure because of their influences on mechanical properties of materials. Surface SH-wave which is horizontally polarized shear wave traveling along near surface and subsurface layer is an attractive technique for material evaluation. The destructive method is widely used for the estimation of material degradation but it has a great difficulty in preparing specimens from in-service industrial facilities. In this study, nondestructive evaluation for degraded structural materials used at high temperature though surface SH-wave method is discussed. 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at $650^{\circ}$ were evaluated though ultrasonic nondestructive evaluation techniques investigating the change of sound velocity, attenuation coefficient and amplitude spectra. In addition, it has verified experimentally the frequency-dependence of attenuation coefficient though wavelet analysis method.

  • PDF

Annealing effects of ZnO:Er films on UV emission (ZnO:Er막의 UV 발광에 미치는 열처리 효과)

  • Choi, Mu-Hee;Ma, Tae-Young
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.316-321
    • /
    • 2009
  • Er-doped ZnO(ZnO:Er) films were deposited onto MgO wafers by ultrasonic spray pyrolysis at 550 $^{\circ}C$ varying the concentration of Er in the deposition source from 0.5 wt% to 3.0 wt%. Annealing of the films in a vacuum was carried out to increase the intensity of ultraviolet(UV) emission from the films. The annealing temperature was between 600$^{\circ}C$ and 800$^{\circ}C$. The crystallographic properties and surface morphology of the films were investigated by X-ray diffraction(XRD)and scanning electron microscope(SEM), respectively. The properties of photoluminescence(PL) for the films were investigated by the dependence of PL spectra on the annealing temperature. X-ray photoelectron spectroscopy(XPS) was conducted to find the composition change in the films by the annealing.