• Title/Summary/Keyword: Ultrasonic condition

Search Result 438, Processing Time 0.025 seconds

Effect of Ultrasound on the Mechanical Properties of Electrodeposited Ni-SiC Nano Composite

  • Gyawali, Gobinda;Cho, Sung-Hun;Woo, Dong-Jin;Lee, Soo-Wohn
    • Korean Journal of Materials Research
    • /
    • v.20 no.8
    • /
    • pp.439-443
    • /
    • 2010
  • Nano sized SiC particles (270 nm) are easily agglomerated in nickel sulfamate electrolytic bath during a composite electrodeposition process. The agglomeration of nano particles in composite coatings can significantly reduce the mechanical properties of the composite coatings. In this study, Ni-SiC nano composite coatings were fabricated using a conventional electrodeposition process with the aid of ultrasound. Nano particles were found to be distributed homogeneously with reduced agglomeration in the ultrasonicated samples. Substantial improvements in mechanical properties were observed in the composite coatings prepared in presence of ultrasound over those without ultrasound. Ni-SiC composite coatings were prepared with variable ultrasonic frequencies ranging from 24 kHz to 78 kHz and ultrasonic powers up to 300 watts. The ultrasonic frequency of 38 kHz with ultrasonic power of 200 watt was revealed to be the best ultrasonic conditions for homogeneous dispersion of nano SiC particles with improved mechanical properties in the composite coatings. The microstructures, phase compositions, and mechanical properties of the composite coatings were observed and evaluated using SEM, XRD, Vickers microhardness, and wear test. The Vickers microhardness of composite coatings under ultrasonic condition was significantly improved as compared to the coatings without ultrasound. The friction coefficient of the composite coating prepared with an ultrasonic condition was also smaller than the pure nickel coatings. A synergistic combination of superior wear resistance and improved microhardness was found in the Ni-SiC composite coatings prepared with ultrasonic conditions.

A Study on the Removal Performance of PM10 by the Air-washer and the Ultrasonic Humidifier (자연 기화식 가습기와 초음파 가습기의 PM10 제거성능)

  • Lee, Joo-Ho;Kim, Sun-Sook;Park, Sung-Kwan;Park, Jun-Hyung;Lee, Yun-Gye
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.720-724
    • /
    • 2008
  • The purpose of this study is to evaluate the PM10 removal efficiencies of an Air-washer and an Ultrasonic humidifier by mock-up experiments. The concentrations of PM10 were measured at 5 minute intervals using $\beta$-Ray method. The average PM10 removal efficiency of the Air-washer was 79.8%, while the PM10 concentrations increased with the operation of Ultrasonic humidifier. In the case of operating the Air-washer, the R.H(Relative Humidity) level of the test room was maintained at around 45%, regardless of initial R.H condition. The R.H of the test room with Ultrasonic humidifier was influenced by the initial R.H condition.

  • PDF

Effect of Ultrasonic Process of Electroless Ni-P-Al2O3 Composite Coatings

  • Yoon, Jin-Doo;Koo, Bon-Heun;Hwang, Hwan-Il;Seo, Sun-Kyo;Park, Jong-Kyu
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.315-323
    • /
    • 2021
  • In general, surface treatments of electroless Ni-P coating are extensively applied in the industry due to their excellent properties for considerable wear resistance, hardness, corrosion resistance. This study aims to determine the effect of ultrasonic conditions on the morphology, alumina content, roughness, hardness, and corrosion resistance of electroless Ni-P-Al2O3 composite coatings. The characteristics were analyzed by Energy-dispersive X-ray spectroscopy (EDX), x-ray diffractions (XRD), and atomic force microscopy (AFM), etc. In this study, the effect of ultrasonic condition uniformly distributed alumina within Ni-P solution resulting in a smoother surface, lower surface roughness. Furthermore, the corrosion resistance behavior of the coating was analyzed using tafel polarization curves in a 3.5 wt.% NaCl solution at 25 ℃. Under ultrasonic, Al2O3 content in Ni-P composite solution increased from 0.5 to 5.0 g/L, Al2O3 content at 3.0 g/L was showed a significantly enhanced corrosion resistance. These results suggested that ultrasonic condition was an effective method to improve the properties of the composite coating.

A Study on the Alkali Hydrolysis of PET fabric with Ultrasonic Application(I) - Decomposition Rate Constant and Activation Energy - (초음파를 적용한 PET 직물의 알칼리 가수분해에 관한 연구(I) - 분해속도상수와 활성화 에너지-)

  • 서말용;조호현;김삼수;전재우;이승구
    • Textile Coloration and Finishing
    • /
    • v.14 no.4
    • /
    • pp.214-222
    • /
    • 2002
  • In order to give a silk-like touch to PET fabrics, the PET fabrics were treated with NaOH alkaline solution in various conditions. In alkaline treatment, the liquor flow type pilot weight reduction apparatus with magnetostrictive ultrasonic transducer was used for the study. The weight loss of PET fabrics hydrolyzed in 4% and 6% NaOH solution, at $95^\circ{C}$ and $99^\circ{C}$ for 60min. with ultrasonic application showed 3.7~4.6% higher than that of treated fabric without ultrasonic application. From the difference of specific weight loss, the treatment condition of the maximum of hydrolyzation effect appeared at $95^\circ{C}$ in $4^\circ{C}$ and at $90^\circ{C}$ in 6% NaOH solution, respectively. During the alkali hydrolysis of PET fabrics, the decomposition rate constant(k) increased exponentially with the treatment temperature and were not related with ultrasonic cavitation. The activation energy$(E_a)$ in decomposition of PET fabrics were 21.06kcal/mol with ultrasonic application and 21.10kcal/mol without ultrasonic application. The ultrasonic application gave a little higher value of the activation entropy$(\Delta{S}^\neq)$ and a little lower value of Gibbs free energy$(\Delta{S}^\neq)$ compared with not used ultrasonic apparatus.

A Study on a Ultrasonic Vibration Assisted Grinding of Alumina Ceramic with Diamond Grinding Tool (초음파 진동을 하는 다이아몬드 연삭공구의 알루미나 세라믹 연삭 가공에 관한 연구)

  • Choi, Young-Jae;Song, Ki-Hyeong;Park, Kyung-Hee;Hong, Yun-Hyuck;Kim, Kyeong-Tae;Lee, Seok-Woo;Choi, Hon-Zong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.1
    • /
    • pp.13-19
    • /
    • 2012
  • In this study, ultrasonic vibration tool designed and made by using FEM analysis. And machining test was carried out in various machining conditions using ultrasonic vibration capable CNC machine. For work material, alumina ceramic ($Al_2O_3$) was used while for tool material diamond electroplated grinding wheel was used. To evaluate ultrasonic vibration effect, grinding test was performed with and without ultrasonic vibration in same machining condition. In ultrasonic mode, ultrasonic vibration of 20kHz was generated by HSK 63 ultrasonic actuator. The two grinding speeds, 1.67m/s and 3.35m/s, were applied. On the other hand, grinding forces were measured by KISTLER dynamometer.

A Study on the Aluminum Wire Bondingby Using Ultrasonic Vibrator (초음파 진동자를 이용한 알루미늄 와이어 용접에 관한 연구)

  • 김희수;이건복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.571-576
    • /
    • 1994
  • In recent years, ultrasonic has been widely applied in measurement and industrial fields and its application range has been expanded as a result of continuous research and development. Wire Bonding Machine, an instrument fabricating semi-conductor, makes use of ultrasonic bonding method. In order to improve the currently used wire bonding machine using ultrasonic energy, technical accumulation is needed steadily through development of exciting device of ultrasonic composed of piezoelectic vibrator and horn. This study investigates the design conditions affecting the dynamic characteristics through the theoretical and experimental analysis of piezoelectric vibrator and horn, The study conducts separately the system identification of piezoelectric vibrator in time domain and the modal analysis of horn in frequency domain. In theoretical model, the integrated modeling is conducted via a combination of dynamic identification of piezoelectric vibrator and theoretical analysis of horn. Hence comparison is made for theoretical and experimental results of the dynamic characteristics of the ultrasonic transducer composed of piezoelectric vibrator and horn. Form the results of this study we develop the design technique of ultrasonic transducer using dynamic characteristic analysis and propose the possibility of ultrasonic welding considering the optimal condition of the natural frequency and vibration mode of horn.

  • PDF

Preparation of Fullerene Oxides by Fullerenes[$C_{60},C_{70}$] with Several Oxidants under Ultrasonic Condition (초음파 조건에서 산화제를 이용한 풀러렌 산화물의 제조)

  • Kown, Sock-Chan;Jeong, Hong-Seok;Ko, Weon-Bae
    • Elastomers and Composites
    • /
    • v.38 no.2
    • /
    • pp.147-156
    • /
    • 2003
  • Synthesis of fullerene oxides by fullerenes [$C_{60},\;C_{70}$] and several oxidants such as benzoylperoxide, trichloroisocyanuric acid, methyltrioxorhenium(VII), iodosobenzene, phosphorous pentoxide take place under ultrasonic condition at room temperature. The MALDI-TOF MS,UV-visible spectra and HPLC analysis confirmed that the products of fullerenes oxidation are [$C_{60}(O)_n$], ($n=1{\sim}3$ or n=1) and [$C_{70}(O)_n$], ($n=1{\sim}2$ or n=1). As compared with the reactivity of epoxidation of fullerenes [$C_{60},\;C_{70}$], the reaction rate of $C_{70}$ was lower than that of $C_{60}$ under same reaction condition.

Reuse of HPLC Guard Column by Ultrasonic Cleaning

  • Lee, Byung-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.459-465
    • /
    • 2016
  • This study investigated reusability of costly guard column by ultrasonic. It also investigated various effects that affect to guard column generation by ultrasonic. When investigated 30 KHz of frequency, area of ascorbic acid is 73.0% compared to unused guard column. As a result of investigation of effect of pH, guard column by ultrasonic is effective at alkali area. As a result of investigation of solvent effect, when ethanol is used, generation rate is 81.9% as of peak area compared to the case of analysis in un used column. From the result, it indicates that regenerated guard by ultrasonic is reusable.

A study on the development of atomizer of the complete combustion for diesel engines (디젤기관의 완전연소용 무화기의 개발)

  • 조규상;류정인
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.26-35
    • /
    • 1990
  • This is an experimental study to investigate the characteristics of Diesel spray and Diesel engine performance using ultrasonic injection nozzle (A, B type) and conventional commercial injection nozzle (C type). The results are obtained as follows: 1. SMD and range of size distribution of Diesel spray using the ultrasonic nozzle are smaller than those using the conventional injection nozzle, and spray angle is spread. 2. Because of the difference of the ultrasonic vibration energy transfer in the same condition, the effects of A-type ultrasonic vibration are larger than those of B-type ultrasonic vibration. 3. Attaching the ultrasonic vibrator to the conventional injection nozzle of the Diesel engine, engine performances i.e. BMEP, BSFC, and cylinder peak pressure are improved.

  • PDF

The 3-D Underwater Object Recognition Using Neural Networks and Ultrasonic Sensor Fabricated with 1-3 Type Piezoelectric Composites (1-3형 압전복합체로 제작한 초음파센서와 신경회로망을 이용한 3차원 수중 물체인식)

  • 조현철;이기성
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.324-325
    • /
    • 2001
  • In this study, the characteristics of ultrasonic sensor fabricated with PZT-Polymer 1-3 type composites are investigated. The 3-D Underwater object recognition using the self-made ultrasonic sensor and SOFM neural network is presented. The ultrasonic sensor is satisfied with the required condition of commercial ultrasonic sensor in underwater. The 3-D underwater object recognition for the training data and the testing data are 100[100%], respectively. The experimental results have shown that the ultrasonic sensor fabricated with PZT-Polymer 1-3 type composites can be applied for sonar system.

  • PDF