• 제목/요약/키워드: Ultrasonic apparatus

검색결과 57건 처리시간 0.023초

초음파 조사가 직접 접촉식 막증발 공정의 막오염과 막젖음에 미치는 영향 (Effect of ultrasonic irradiation on membrane fouling and membrane wetting in direct contact membrane distillation process)

  • 장용선;최용준;이상호
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.343-350
    • /
    • 2016
  • Membrane distillation (MD) is a novel separation process that have drawn attention as an affordable alternative to conventional desalination processes. However, membrane fouling and pore wetting are issues to be addressed prior to widespread application of MD. In this study, the influence of ultrasonic irradiation on fouling and wetting of MD membranes was investigated for better understanding of the MD process. Experiments were carried out using a direct contact membrane distillation apparatus Colloidal silica was used as a model foulants in a synthetic seawater (35,000 mg/L NaCl solution). A vibrator was directed attached to membrane module to generate ultrasonic waves from 25 kHz (the highest energy) to 75 kHz (the lowest energy). Flux and TDS for the distillate water were continuously monitored. Results suggested that ultrasonic irradiation is effective to retard flux decline due to fouling only in the early stage of the MD operation. Moreover, wetting occurred by a long-term application of ultrasonic rradiation at 75 kHz. These results suggest that the conditions for ultrasonic irradiation should be carefully optimized to maximize fouling control and minimize pore wetting.

Evolution of phase morphology and in-situ compatibilization of polymer blends during ultrasound-assisted melt mixing

  • Kim, Hyungsu;Ryu, Joung-Gul;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • 제14권3호
    • /
    • pp.121-128
    • /
    • 2002
  • A series of thermoplastic polymers and their blends were melt-processed with high intensity ultrasonic wave in an intensive mixer. For the effective transfer of ultrasonic energy, an experimental apparatus was specially designed so that polymer melt can directly contact with ultrasonic horn. It was observed that significant variations in the rheological properties of polymers occur due to the unique action of ultrasonic wave without any aid of chemical additives. It was also found that the direct sonication on immiscible polymer blends in melt state reduces the domain sizes considerably and stabilizes the phase morphology of the blends. The degree of compatibilization was strongly affected by viscosity ratio of the components and the morphology was stable after annealing in properly compatibilized blends. It is suggested that ultrasound assisted melt mixing can lead to in-situ copolymer formation between the components and consequently provide an effective route to compatibilize immiscible polymer blends.

용접결함 검사용 수침식초음파탐상기의 매질개선연구 (A Study on Couplant Medium Improvement for Ultrasonic Inspection System with Water Immersion to Detect Weld Defects)

  • 정달우;최낙삼;박용배
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.8-14
    • /
    • 2008
  • For nondestructive inspection of electron beam (EB) welding part in automotive power transmission assembly, a pulse-echo ultrasonic testing apparatus in water immersion has been applied using the ultrasonic waves with a frequency of 10MHz. However various problems have appeared during the ultrasonic inspection, which led to some significant mistakes in automatic quality evaluation of the welding parts. Experimental study showed that the state of water couplant medium containing some amount of contaminants, rusts and anti-corrosion agents had considerable influences on the reduction of ultrasonic amplitudes during wave propagation. The amplitude reduction depending on the coupling medium state could bring about some mis-diagnoses for defects in the welding parts. The results proposed that for a reliable inspection of defects in welds the state of water medium should be kept in about 15 volume fractions (vol.%) of anti-corrosion agents and in minimized contaminants.

초음파 진동 딥 드로잉 공정에서의 마찰감소효과 분석을 위한 유한요소해석 및 실험 (FEA and Experiment Investigation on the Friction Reduction for Ultrasonic Vibration Assisted Deep Drawing)

  • 김상우;손영길;이영선
    • 소성∙가공
    • /
    • 제23권7호
    • /
    • pp.413-418
    • /
    • 2014
  • The current study presents experimental and numerical results on the effect of ultrasonic vibrations on a cylindrical cup drawing of a cold rolled steel sheet(SPCC). An experimental apparatus, which can superimpose high frequency oscillations during deep drawing, was constructed by installing on the tooling ultrasonic vibration generators consisting of a piezoelectric transducer and a resonator. Conventional and vibration-assisted cylindrical deep drawing tests were conducted for various drawing ratios, and the limiting drawing ratios(LDR) for both methods were compared. To evaluate quantitatively the contribution from the ultrasonic vibrations to the reduction of friction between tools and material finite element analyses were conducted. Through a series of parametric analyses, the friction coefficients, which minimized the differences of punch load data between the experiments and simulations, were determined. The results show that the application of ultrasonic vibration effectively improves the LDR by reducing the friction between the tools and the material.

초음파 진동이 경사진 평판에서의 CHF에 미치는 영향에 대한 실험연구 (Experimental Study of the Ultrasonic Vibration Effects on CHF Occurring on Inclined Flat Surfaces)

  • 정지환;김대훈;권영철
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.139-144
    • /
    • 2003
  • 본 연구는 초음파 진동의 영향을 받는 풀비등 조건에서의 CHF 열전달 촉진현상을 이해하기 위해 수행되었다. 평판에 얇은 구리박판이 덮여 있는 시료와 증류수를 냉각제로 사용하여 초음파 유무, 경사각도의 변화 및 물의 과냉도 변화에 대하여 평판 가열면에서의 CHF를 측정하였다. 실험장치는 수조, 전원공급장치, 시험부, 초음파 발생장치, 데이터 획득장치 등으로 구성되었다. 실험조건은 3가지 과냉도에 대한 실험과 6가지 시편의 경사각도를 변화시켜 수행되었다. 측정값을 통해 초음파 진동이 CHF를 증진시키며, 그 영향은 경사각의 변화뿐만 아니라 과냉도에 따라서 크기가 달라지는 것을 알 수 있다. 초음파 진동에 의한 CHF증가율은 과냉도가 커질수록, 그리고 시편의 경사각도가 수직에서 수평하향 방향으로 기울어질수록 증가하였다. 가시화 실험을 통해 CHF 증가의 원인이 음장에서 기포 생성과 이탈의 동적거동과 밀접하게 관련되어 있음을 확인하였다.

기구조작후 치근표면의 조도에 관한 연구; 3차원 측정기틀 이용한 in vitro 연구 (Root surface roughness following mechanical instrumentation, in vitro 3 dimensional planimetric study)

  • 이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제28권4호
    • /
    • pp.823-828
    • /
    • 1998
  • A primary goal of periodontal therapy is the creation of root surfaces that are free of plaque and calculus. It is not yet to be determined whether it is desirable to have a smooth root surface after treatment. It is also not clear what degree of roughness result from different instruments. In the present study various instruments for root surface debridement were evaluated. 20 extracted teeth were utilized, and the teeth were treated with one of the following instrument: Gracey curette, Perio Clean, and piezo ultrasonic device(Setlec, P Max) with general scaler tip, curette-like tip, and diamond tip. 3 dimensional planimetric device(Accura) was used to evaluate the average surface roughness. It was demonstrated hand and power-driven instruments did not have a significant difference in roughness of the root surface following instrumentation. And ultrasonic scaler tip tended to make a most smooth surface than other instruments. The possible reasons of the result were discussed.

  • PDF

초음파 모터 구동 역감 장치에 부착한 전기자극 촉감 장치의 설계 (Design of the Electric Stimulus Tactile Apparatus Loaded on the Haptic Interface Using Ultrasonic Motors)

  • 김동옥;강원찬;김성철;오금곤;김영동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.9-13
    • /
    • 2001
  • This paper proposes the electric stimulus tactile apparatus system(TESTAS) loaded on the hap-tic interface using ultrasonic motors(USMs). To touch the virtual object like wall in graphic, the 6 DOF haptic interface provides force feedback to users as if it is real. But the case of sharp virtual object like a puncture, it could not provided the sense of pain, but only the reaction-force. After the TESTAS had been loaded on this haptic interface. it could Provide not only the force but also the pain to users. To estimate the capability of TESTAS, we did experiments of three cases, one was very sharp, another was dull, the other is continuative contact.

  • PDF

초음파를 적용한 PET 직물의 알칼리 가수분해에 관한 연구(II) - 기공특성과 올리고머 분석 - (A Study on the Alkali Hydrolysis of PET fabrics with Ultrasonic Application(II)- Surface Porosity and Oligomer Analysis -)

  • 김삼수;서말용;박성우;윤태희;이승구;허만우
    • 한국염색가공학회지
    • /
    • 제14권6호
    • /
    • pp.305-312
    • /
    • 2002
  • In order to give a silk-like touch to PET fabrics, the PET fabrics were treated with NaOH alkaline solution in various conditions. In alkaline treatment, the liquor flow type pilot weight reduction apparatus with magnetostrictive ultrasonic transducer was used for the study. The effects of ultrasonic application, treatment time and temperature at NaOH 4% and 6"A solution on the decomposition rate of PET fabrics. From the results of the decomposition rate of PET fabrics, the qualitative and quantitative analysis of oligomer after decomposition of PET fabrics carried out by the HPLC. On the other hand, the surface pore characteristics of decomposition PET fabrics measured by porosimetery. The pore characteristics on the surface of treated PET fiber depended on the decomposition rate and did not depend on the ultrasonic cavitation. The pore diameter of alkaline untreated PET fiber were 15A and those of treated PET fibers were 5~6$\AA$ at the maximum pore volume. The average pore sizes of fiber before and after treatment were 141 h and 160h, respectively. Total amount of oligomer of the untreated PET fibers were 1.70wt% and 67.7% of total oligomer occupied with PET cyclic trimer and PET cyclic tetramer. Total amount of oligomer of fiber with 26.9% and 48.0% of weight loss without ultrasonic application were 1.78wt% and 1.79wt%, respectively. Also total amount oligomer of fibers which were reduced 27.7% and 48.2% of weight loss with ultrasonic application were 1.74wt%. This result showed that the removal rate of oligomer in the process of alkaline hydrolysis with ultrasonic higher than that of without ultrasonic application.tion.

초음파 분사 열분해 장치에서 제조된 $TiO_2/SiO_2$ 복합 분체의 UV 차단 효과 (UV Blocking Effect of $TiO_2/SiO_2$ Composite Powders Prepared by Ultrasonic Spray Pyrolysis)

  • 이동규;이진화;김동식
    • 한국응용과학기술학회지
    • /
    • 제22권3호
    • /
    • pp.281-288
    • /
    • 2005
  • The silica nanoparticles were used as support of catalyst, filling material, electronic assembler, thin film material, and sensor material. And, the titania nanoparticles were used as pigment, dielectric substance, sensor and photocatalyst. In this paper, the spherical composite particles of $TiO_2/SiO_2$with narrow size distribution and phase pure were synthesized by ultrasonic spray pyrolysis method from $TiOSO_4$ and colloidal silica solution. Using ultrasonic apparatus, this starting solution was vaporized to droplets, and these droplets were induced into tube furnace by carrier gas. The resulting composite powder was characterized by scanning electron microscopy, X-ray diffraction analysis, TG-DTA, in vitro sun protection factor(SPF) and BET surface area analysis.

Construction of a Pilot Headbox System and Pressure Monitoring Apparatus for the Development of High Speed Hydraulic Headboxes

  • Youn, Hye-Jung;Lee, Hak-Lae
    • 펄프종이기술
    • /
    • 제35권5호
    • /
    • pp.37-45
    • /
    • 2003
  • To investigate the influence of the design and operating parameters of the headbox on hydrodynamics, a pilot headbox system and pressure monitoring apparatus were constructed. The pilot headbox system consisted of a circulating water reservoir, centrifugal pump, distributor, turbulence generator and slice. The distributor was designed to function as a pressure attenuator. Flow rate to the headbox and MD and CD velocity profiles in the slice zone were monitored using an ultrasonic flowmeter and Pitot tubes, respectively. As the distance from the step diffusor increased, evener CD velocity profile was observed. Wall effect increased with the increase of the velocity. Flow stability in the headbox was evaluated by injecting a dye at the outlet of the distributor. Application of theoretical analysis based on CFD in designing headboxes is briefly discussed.