• Title/Summary/Keyword: Ultrasonic Signal

Search Result 638, Processing Time 0.027 seconds

A New Frame Synchronization Scheme for Underwater Ultrasonic Image Burst Transmission System (초음파를 이용한 수중 영상 버스트 전송 시스템을 위한 새로운 프레임 동기 방안)

  • Kim, Seung-Geun;Choi, Young-Chol;Park, Jong-Won;Kim, Sea-Moon;Lim, Yong-Gon;Kim, Sang-Tae
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.336-340
    • /
    • 2003
  • The frame synchronization should be acquired before performing other data-aided receiving algorithms, such as data-aided channel equalizing, beam-forming and phase, symbol timing, and frequency synchronizing, since all of them are using preamble or training sequence to estimate the amount of error from the received signal. In this paper, we present a new frame synchronization scheme for underwater ultrasonic image burst transmission system, which computes the correlation between received symbol sequence and one CAZAC sequence, composed of the latter half of the first CAZAC sequence of preamble and the first half of the second CAZAC sequence of preamble and then compares a threshold value. If the correlation value is bigger than the threshold value, the frame detector determines that the frame synchronization is achieved at that sample.

  • PDF

Fabrication of Water Level Limit Sensor Utilizing Acoustic Impedance Matching (음향임피던스 정합을 이용한 액면레벨 Limit센서의 구현)

  • Kim, Cheol-Han;Lee, Su-Ho;SaGong, Geon;Lee, Jun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1870-1872
    • /
    • 2005
  • In this study, an ultrasonic level limit sensor with a new structure utilizing the acoustic impedance matching is proposed to be able to check it out a change of water-level. 2 PZT resonators with the same property are bonded directly on the polyethylene plate. One resonator is for transmitter as an ultrasonic transducer, the other one is for receiver. In this case, a polyethylene plate will operate as an acoustic guider to transmit a transverse wave between 2 PZT resonators in air. While in the water, a polyethylene plate having a similar acoustic impedance with the water will be emitted an acoustic energy into the water as a longitudinal wave. According to this mechanism, there was a wide difference of acoustic signal output between underwater and in air. As a summary, this proposed level limit sensor could be used as a strong candidate with low cost and more stable one.

  • PDF

A New Method for Extending Doppler Mean Frequency in Ultrasonic Imaging Systems (초음파 영상 시스템에서 새로운 도플러 평균주파수 확장 방법)

  • Kwon, Sung-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1047-1056
    • /
    • 2007
  • Basically, an ultrasonic imaging system has two fundamental imaging modes available. One is the B-mode imaging modality which provides an image of reflection coefficient, and the other is the Doppler color flow mode that maps blood flow inside the human heart and blood vessels. This paper presents a new method of detecting and compensating for aliasing that occurs when the Doppler frequency exceeds one-half of the pulse-repetition frequency (PRF). Its validity is shown by computer simulation. The new method not only extends the measurable Doppler frequency, but also helps to reduce the effect of noise. The results show that the aliasing can be compensated for correctly fur signal-to-noise ratios down to 20 dB.

  • PDF

A Research on Smart Stick for the Blind (시각 장애인을 위한 스마트 지팡이에 관한 연구)

  • El-Koka, Ahmed;Kang, Dae-Ki
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.1174-1176
    • /
    • 2011
  • Unfortunately, the number of blind people increases every 5 seconds in our world. An extensive research was made on improving the conventional walking cane and developing a microcontroller based walking stick for the blind with sensors and a feedback in form of vibration. Two different kinds of sensors are used to detect obstacles, ultrasonic and infrared distance sensors. The signal from an ultrasonic sensor is fed to a microcontroller. With the help of the supporting software, the Pulse Width Modulation (PWM) principle is extensively used to form three zones and run the corresponding vibration motor at different spends according to how far the detected object is located. The other infrared distance sensors are connected to amplifiers and after that to their corresponding vibration motors through motor drivers. The vibration motors are to be located around the user's arm to notify the blind of the obstacles in the intended walking way. It can be very reliable and sufficient device guiding the blind other than the conventional walking cane which has many drawbacks which will be explained and discussed.

Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide (도파띠를 이용한 고온 액침 초음파센서의 가능성 연구)

  • Choi, M.S.;Lee, J.P.;Jung, T.E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.151-156
    • /
    • 1994
  • Exertion has been made to develop high-temperature (about $250{\sim}650^{\circ}C$) immersion ultrasonic sensor for the visualization of objects, temperature measurement, dimensional check, or nondestructive testing of welds under liquid sodium. In this study, the feasibility of the ultrasonic sensor taking advantage of a strip waveguide was confirmed by water-experiment. The lowest order of antisymmetric Lamb wave was used in the frequency range with negligible dispersion. This plate wave was excited in the stainless steel strip waveguide of 1.0mm thickness and 13mm width by the comb-structure transducer of 2.3MHz frequency. Its attenuation coefficient was 1.2dB/m in air and 380dB/m in water. The signal to noise ratio of 25dB was obtained from a planar reflector 270mm away from the beam aperture of $13mm{\times}39mm$ size.

  • PDF

Development and Evaluation of Real-time Acoustic Detection System of Harmful Red-tide Using Ultrasonic Sound (초음파를 이용한 유해적조의 실시간 음향탐지 시스템 개발 및 평가)

  • Kang, Donhyug;Lim, Seonho;Lee, Hyungbeen;Doh, Jaewon;Lee, Youn-Ho;Choi, Jee Woong
    • Ocean and Polar Research
    • /
    • v.35 no.1
    • /
    • pp.15-26
    • /
    • 2013
  • The toxic, Harmful Algal Blooms (HABs) caused by the Cochlodinium polykrikoides have a serious impact on the coastal waters of Korea. In this study, the acoustic detection system was developed for rapid HABs detection, based on the acoustic backscattering properties of the C. polykrikoides. The developed system was mainly composed of a pulser-receiver board, a signal processor board, a control board, a network board, a power board, ultrasonic sensors (3.5 and 5.0 MHz), an environmental sensor, GPS, and a land-based control unit. To evaluate the performance of the system, a trail was done at a laboratory, and two in situ trials were conducted: (1) when there was no red tide, and (2) when there was red tide. In the laboratory evaluation, the system performed well in accordance with the number of C. polykrikoides in the received level. Second, under the condition when there was no red tide in the field, there was a good correlation between the acoustic data and sampling data. Finally, under the condition when there was red tide in the field, the system successfully worked at various densities in accordance with the number of C. polykrikoides, and the results corresponded with the sampling data and monitoring result of NFRDI (National Fisheries Research & Development Institute). From the laboratory and field evaluations, the developed acoustic detection system for early detecting HABs has demonstrated that it could be a significant system to monitor the occurrence of HABs in coastal regions.

Pet Location Tracking and Remote Monitoring System using a Wireless Sensor Network (무선센서네트워크를 이용한 애완동물 위치추적 및 원격모니터링 시스템)

  • Hwang, Sung-Ho;Park, Jae-Choon;Kwon, Ki-Hyeon;Choi, Shin-Hyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.351-356
    • /
    • 2011
  • In this paper, we design a pet location tracking and remote monitoring system that uses ultrasonic, temperature, humidity and illumination sensors to study behavioral patterns and habits. Using ultrasonic waves to calculate distances, a WSN(Wireless Sensor Network) was constructed to transmit data at pet's location, such as temperature, humidity and illumination, to a sink mote. Data received by the system are stored in the database in real time to trace pet's location. Interference among transmitting motes was eliminated by sequentially transmitting RF beacons using sink mote's beacon as the reference signal. Experiments were performed with the laboratory prototype of a pet animal monitoring system implemented for this study. The system analyzes locations of a pet and displays movement patterns, areas of movement, temperature, humidity and illumination using a GUI (graphical user interface).

Ultrasonic Flaw Detection in Turbine Rotor Disc Keyway Using Neural Network (신경회로망을 이용한 터빈로타 디스크 키웨이의 결함 검출)

  • Son, Young-Ho;Lee, Jong-O;Yoon, Woon-Ha;Lee, Byung-Woo;Seo, Won-Chan;Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.45-52
    • /
    • 2003
  • A number of stress corrosion cracks in turbine rotor disk keyway in power plants have been found and the necessity has been raised to detect and evaluate the cracks prior to the catastrophic failure of turbine disk. By ultrasonic RF signal analysis and using a neural network based on bark-propagation algorithm, we tried to evaluate the location, size and orientation of cracks around keyway. Because RF signals received from each reflector have a number of peaks, they were processed to have a single peak for each reflector. Using the processed RF signals, scan data that contain the information on the position of transducer and the arrival time of reflected waves from each reflector were obtained. The time difference between each reflector and the position of transducer extracted from the scan data were then applied to the back-propagation neural network. As a result, the neural network was found useful to evaluate the location, size and orientation of cracks initiated from keyway.

Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor (소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발)

  • Joo, Young-Sang;Bae, Jin-Ho;Park, Chang-Gyu;Lee, Jae-Han;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • A double rotation C-scanning system and a software program Under-Sodium MultiVIEW have been developed for the under-sodium viewing of a reactor core and in-vessel structures of a sodium-cooled fast reactor KALIMER-600. Double rotation C-scanning system has been designed and manufactured by the reproduction of double rotation plug of a reactor head in KALIMER-600. Hardware system which consists of a double rotating scanner, ultrasonic waveguide sensors, a high power ultrasonic pulser-receiver, a scanner driving module and a multi channel A/D board have been constructed. The functions of scanner control, image mapping and signal processing of Under-Sodium MultiVIEW program have been implemented by using a LabVIEW graphical programming language. The performance of Under-Sodium MultiVIEW program was verified by a double rotation C-scanning test in water.

The Ultrasonic Image Processing by Peak Value, Time Average and Depth Profile Technique in High Frequency Bandwidth (고주파대역에서 피크값, Time Average 및 Depth Profile 초음파 영상처리)

  • 이종호
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.3
    • /
    • pp.120-127
    • /
    • 1998
  • In this paper, ultrasonic images of 25MHz bandwidth were acquired by applying peak value variation, time average and depth profile algorithm to acoustic microscopy and its performance was compared and analysed with each other. In the time average algorithm, total reflecting pulse wave from a spot on the coin was converted to digital data in time domain and average value of the converted 512 data was calculated in computer. Time average image was displayed by gray levels colour of acquired N x N matrix average data in the scanning area on the sample. This technique having smoothing effects in time domain make developed an ultrasonic image on a highly scattering area. In depth profile technique, time difference between the reference and the reflected signal was detected with minimum resolution performance of 2ns, thus we can acquired real 3 dimensional shape of the scanning area in accordance with relative magnitude. Through these experiments, peak value, time average and depth profile images were analysed and advantages of each algorithm were proposed.

  • PDF