• Title/Summary/Keyword: Ultrasonic Material

Search Result 894, Processing Time 0.023 seconds

Alpha-glucosidase Inhibition Activity of Methanol Extracts Obtained from Nine Pteridophyte Species Native to Korea (자생 양치식물 9종의 성엽 및 근경 추출물의 α-glucosidase 억제 활성)

  • Kim, Na Rae;Chi, Lai Won;Lee, Cheol Hee
    • Korean Journal of Plant Resources
    • /
    • v.26 no.4
    • /
    • pp.411-416
    • /
    • 2013
  • This study was conducted not only to analyze ${\alpha}$-glucosidase inhibition activity with fronds and rhizomes of nine Pteridophyte species, but also to select the plant materials suitable for natural ${\alpha}$-glucosidase inhibitor. Harvested rhizomes and fronds were washed, freeze-dried and grinded. After conducting ultrasonification extraction for 30 minutes in ultrasonic water tank with 100% methanol solvent, and vacuum filtration, ${\alpha}$-glucosidase inhibition activity was measured. Acarbose was used as the positive control. After mixing $100{\mu}L$ of 0.7 unit ${\alpha}$-glucosidase enzyme solution into $50{\mu}L$ of extract and reacting them at $37^{\circ}C$ for 10 minutes, $50{\mu}L$ of 1.5 mM ${\rho}$-NPG solution was taken and reacted at $37^{\circ}C$ for 20 minutes. The reaction was stopped with 1 mL of 1 M $Na_2CO_3$ and absorbance was measured in 405 nm. With the regression analysis, the content of solubility solids (the value of $IC_{50}$) which can inhibit 50% of 0.7 unit ${\alpha}$-glucosidase solution's activity was investigated. The frond ($IC_{50}=14.00{\sim}913.33{\mu}g{\cdot}mL^{-1}$) and rhizome extracts ($IC_{50}=12.93{\sim}205.84{\mu}g{\cdot}mL^{-1}$) of nine Pteridophyte species showed higher ${\alpha}$-glucosidase inhibition activity in comparison with acarbose ($IC_{50}=1413.70{\mu}g{\cdot}mL^{-1}$). The extracts of fronds and rhizomes showed higher value than acarbose by 1.55~100.98 and 6.87~109.33 times each. Especially, ${\alpha}$-glucosidase inhibition activities of Pyrrosia lingua in fronds and Osmunda cinnamomea var. fokiensis in rhizomes were the highest. The necessary biomass of fronds and rhizomes for inhibiting 50% of ${\alpha}$-glucosidase activity showed the lowest value, 0.35, 0.27 mg each, in O. cinnamomea var. fokiensis. $IC_{50}$ value of P. lingua was the highest among fronds of nine Pteridophyte species, but content of soluble solids was 2.4 times less than O. cinnamomea var. fokiensis. So frond of O. cinnamomea var. fokiensis is more economic in comparison with P. lingua. As the result of this study, O. cinnamomea var. fokiensis showed high ${\alpha}$-glucosidase inhibition activity even with small biomass. Therefore it was considered to be high-valued economic material as natural ${\alpha}$-glucosidase inhibitor.

The effect of copper alloy scaler tip on the surface roughness of dental implant and restorative materials (구리 합금 초음파 스케일러 팁이 치과 임플란트 및 수복 재료 표면에 미치는 영향)

  • Lee, Ah-Reum;Chung, Chung-Hoon;Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • Purpose: This study is designed to investigate the various impacts of different types of scaler tips such as cooper alloy base tip and the others on the surface roughness of teeth and implant by the method which is currently in clinical use. Materials and methods: Four different types of disc shaped porcelain, titanium, zirconia, and Type III gold alloy dental materials sized 15 mm diameter, 1.5 mm thickness were used for the experiment. Plastic hand curette (Group PS), cooper alloy new tip (Group IS), and stainless steel tip (Group SS) were used as testing appliances. A total of 64 specimens were used for this study; Four specimens for each material and appliance group. Surface roughness was formed with 15 degree angle in ultrasonic scaler tip and with 45 degree angle in hand curette of instrument tip and the specimen surface with 5 mm long, one horizontal-reciprocating motion per second for 30 seconds by 40 g force. To survey the surface roughness of each specimen, a field emission scanning electron microscope, an atomic force microscope, and a surface profiler were used. (Ra, ${\mu}m$). Results: According to SEM, most increased surface roughness was observed in SS group while IS groups had minimal roughness change. Measurement by atomic force microscope presented that the surface roughness of SS group was significantly greater than those of PS, IS and control groups in the type III gold alloy group (P<.05). IS group showed lesser surface roughness changes compared to SS group in porcelain and gold alloy group (P<.05). According to surface profiler, surface roughness of SS group showed greater than those of PS, IS and control groups and IS group showed lesser than those of SS group in all specimen groups. Type III gold alloy group had large changes on surface roughness than those of porcelain, titanium, zirconia (P<.05). Conclusion: The result of this study showed that newly developed copper alloy scaler tip can cause minimal roughness impacts on the surface of implant and dental materials; therefore this may be a useful alternative for prophylaxis of implant and restored teeth.

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.