• Title/Summary/Keyword: Ultrasonic Examination

Search Result 130, Processing Time 0.029 seconds

Study on the Development of Three-Dimensional Positioning System and Numerical Modeling of Fish Behavior III. Examination of the Numerical Model by the Field Experiment (3차원 어군행동 계측 시스템 개발과 어군 행동의 수치 모델링에 관한 연구 III. 현장실험에 의한 수치 모델의 검토)

  • 장호영;김동수;김영섭
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.1
    • /
    • pp.18-23
    • /
    • 2001
  • In this paper, the several indexes represented by swimming characteristics of aquarcultured red seabream, Dchrysophrys majors in a farming water raft(10L×10W×5H) were measured by ultrasonic telemetry. The fishes tagged by pingers were tracked by the LBL method(Shin etc., 1994). The location of fishes were calculated by the hyperbolic method and the indexes were estimated by the least square method. The similarity was confirmed by the comparision between experiment and simulation on the swimming trajectory of fishes, the mean distance of individual from wall, the mean swimming speed and the mean distance between the nearest individuals. The obtained results are summerized as follows ; 1. The swimming trajectory of fishes tagged by the pingers and the swimming trajectory by the simulation for 120 minutes showed a simularity. 2. The mean swimming speed by the experiment and the simulation showed 39.2 ㎝/sec (1.4BL ㎝/sec) and 44.4 ㎝/sec (1.6BL ㎝/sec), respectively. 3. The mean swimming depth by the experiment and the simulation showed 238㎝ and 248 ㎝, respectively. 4. The mean distance of individuals from wall of the farming water raft by the experiment and the simulation showed 132 cm and 129 cm, respectively. 5. The mean distance between the nearest individuals by the experiment and the simulation showed 83 ㎝ and 61 ㎝, respectively.

  • PDF

A Study on Changes in Body Surface Temperature and Thermal Effect According to Ultrasound Mode (초음파 진단모드에 따른 체표면 온도변화와 열효과에 관한 고찰)

  • Yang, Sung-Hee;Lee, Jin-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.213-218
    • /
    • 2017
  • Recently, as the number of high-risk pregnancies increases, the use of new techniques such as Doppler, which have higher acoustic power than in the past, has been increasingly used in prenatal diagnosis and guidelines have been set up by various organizations to prevent excessive exposure. Therefore, in this study, we tried to investigate the temperature change of the body surface for each test mode according to the long time ultrasound examination and to examine the exposure time which is not influenced by the thermal effect. B mode, C mode, and PD mode according to time, and the temperature difference between exposed and unexposed sites were compared. As a result, the B mode showed a significant difference in the temperature change from 10 minutes, 50 minutes after exposed, 20 minutes from the C mode, and 30 minutes from the PD mode (p<0.01). In all three modes, the temperature difference was different (p<0.000), and PD mode was the most sensitive to temperature change. Also, it was found that the temperature rise time was shortened with the increase of the ultrasonic exposure time. Therefore, it is recommended that ultrasonography to observe the embryo or fetus should be used only for diagnostic purposes, avoiding excessive test time.

Clinical Significance of the Degree of Fatty Liver Diagnosed by Ultrasonography (초음파검사로 진단된 지방간 정도의 임상적 의의)

  • Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.135-140
    • /
    • 2008
  • Purpose: Fatty liver is one of the most commonly found disease by abdominal ultrasonography. The status of fatty liver is classified into mild, moderate and severe degrees. The study was conducted to investigate the clinical significance of fatty liver using ultrasonography. Materials and method: Test set consisted of 2,185 patients who visited D healthcare center in Daejeon to receive an abdominal ultrasonic test from January to December 2007. Out of the 2185 patients, 524 patients was diagnosed as fatty liver (290 male and 234 female patients). They were divided into three groups, group I for mild degree. II for moderate degree, and III for severe degree, depending on the echo of liver parenchyma, the sound attenuation, and the visibility of intrahepatic blood vessels and diaphragm. Then the correlation of obesity indices, liver function tests and metabolic syndrome was analyzed for males and females separately. Results : As for the degree of fatty liver, 350 cases (66.8%) were classified as group I, 153 cases (29.2%) as group II, and 21 cases (4.1%) as group III. In addition, severe degree of fatty liver was more frequently found in males than in females. The mean ages of three groups for males were 46.1, 44.5, and 39.1, and those for females were 48.8, 50.2, 52.4, respectively. Males with lower mean ages have severely of fatty liver for both males and females. Conclusion: The results in this study show that the classification into three degrees of fatty liver in ultrasonography practice is helpful to treat and observe the progress of fatty liver. In addition, careful examination is required to measure the severity of fatty liver as well as detection of it. A standardized method to classify the degree of fatty liver is also needed for more objective measurement.

  • PDF

INFLUENCE OF INVESTMENT/CERAMIC INTERACTION LAYER ON INTERFACIAL TOUGHNESS OF BODY CERAMIC BONDED TO LITHIA-BASED CERAMIC

  • Park, Ju-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.683-689
    • /
    • 2006
  • Statement of problem. Interfacial toughness is important in the mechanical property of layered dental ceramics such as core-veneered all-ceramic dental materials. The interfaces between adjacent layers must be strongly bonded to prevent delamination, however the weak interface makes delamination by the growth of lateral cracks along the interface. Purpose. The purpose of this study was to determine the effect of the reaction layer on the interfacial fracture toughness of the core/veneer structure according to the five different divesting. Materials and methods. Thirty five heat-pressed Lithia-based ceramic core bars (IPS Empress 2), $20mm{\times}3mm{\times}2mm$ were made following the five different surface divesting conditions. G1 was no dissolution or sandblasting of the interaction layer. G2 and G3 were dissolved layer with 0.2% HF in an ultrasonic unit for 15min and 30 min. G4 and G5 were dissolved layer for 15min and 30min and then same sandblasting for 60s each. We veneered bilayered ceramic bars, $20mm{\times}2.8mm{\times}3.8mm$(2mm core and 1.8mm veneer), according to the manufacturer's instruction. After polishing the specimens through $1{\mu}m$ alumina, we induced five cracks for each of five groups within the veneer close to interface under an applied indenter load of 19.6N with a Vickers microhardness indenter. Results. The results from Vickers hardness were the percentage of delamination G1:55%, G2:50%, G3:35%, G4:0% and G5:0%. SEM examination showed that the mean thickness of the reaction layer were G1 $93.5{\pm}20.6{\mu}m$, G2 $69.9{\pm}14.3{\mu}m$, G3 $59.2{\pm}20.2{\mu}m$, G4 $0.61{\pm}1.44{\mu}m$ G5 $0{\pm}0{\mu}m$. The mean interfacial delamination crack lengths were G1 $131{\pm}54.5{\mu}m$, G2 $85.2{\pm}51.3{\mu}m$, and G3 $94.9{\pm}81.8{\mu}m$. One-way ANOVA showed that there was no statistically significant difference in interfacial crack length among G1, G2 and G3(p> 0.05). Conclusion. The investment reaction layer played important role at the interfacial toughness of body ceramic bonded to Lithia-based ceramic.

Clinical Risk Factor Analysis for Breast Cancer: 568,000 Subjects Undergoing Breast Cancer Screening in Beijing, 2009

  • Pan, Lei;Han, Li-Li;Tao, Li-Xin;Zhou, Tao;Li, Xia;Gao, Qi;Wu, Li-Juan;Luo, Yan-Xia;Ding, Hui;Guo, Xiu-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5325-5329
    • /
    • 2013
  • Objectives: Although there are many reports about the risk of breast cancer, few have reported clinical factors including history of breast-related or other diseases that affect the prevalence of breast cancer. This study explores these risk factors for breast cancer cases reported in Beijing in 2009. Materials and Methods: Data were derived from a Beijing breast cancer screening performed in 2009, of 568,000 women, from 16 districts of Beijing, all aged between 40 and 60 years. In this study, multilevel statistical modeling was used to identify clinical factors that affect the prevalence of breast cancer and to provide more reliable evidence for clinical diagnostics by using screening data. Results and Conclusion: Those women who had organ transplants, compared with those with none, were associated with breast cancer with an odds ratio (OR)=65.352 [95% confidence interval (CI): 8.488-503.165] and those with solid breast mass compared with none had OR=1.384 (95% CI: 1.022-1.873). Malignant tendency was strongly associated with increased risk of breast cancer, OR=207.999(95% CI: 151.950-284.721). The risk of breast cancer increased with age, $OR_1$=2.759 (95% CI: 1.837-4.144, 56-60 vs. 40-45), $OR_2$=2.047 (95% CI: 1.394-3.077, 51-55 vs. 40-45), $OR_3$=1.668 (95% CI: 1.145-2.431). Normal results of B ultrasonic examination show a lower risk among participants, OR= 0.136 (95% CI: 0.085-0.218). Those women with ductal papilloma compared with none were associated with breast cancer, OR=6.524 (95% CI: 1.871-22.746). Therefore, this study suggests that clinical doctors should pay attention to these high-risk factors.

Ultrasonogram as a Diagnostic Modality in Thyroid Tumors (갑상선 결절의 진단에서 초음파의 유용성)

  • Cho Yong-Hwan;Hur Jun;Yoon Dae-Kun;Kim Jeong-Jin;Park Yoon-Kyu;Yoon Dae-Won;Park Sung-Gil
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.1
    • /
    • pp.42-47
    • /
    • 2001
  • Purpose: To evaluate the usefulness of ultrasonogram as a preoperative diagnostic tool in thyroid nodular diseases, this study was carried out. Materials and Methods: From January 1998 to December 1999, 51 patients who underwent thyroidectomy were analyzed retrospectively. We compared the finally histopathological results to ultrasonographical findings such as internal consistency, multiplicity of nodules, nodular ehogenicity, nodular capsule or margin, calcification of nodules. Results: There were 47 females and 4 males with 25 benign tumor, 23 malignant tumor and 3 occult carcinoma in histopathological diagnosis. The solid tumors in ultrasonography carried a probability of malignancy as 66.7%(16/24 cases) whereas cystic or mixed tumors as 16.7%(1/6cases) or 23.8%(5/21cases) (p=0.006). The single nodular diseases carried a high probability of malignancy as 50%(13/26cases) whereas multiple diseases as 28.6%(6/21cases). The hypoechogenicity of thyroid nodular disease showed a probability of malignancy as 60%(9/15cases) whereas mixed-echogenicity as 36.4%(4/11cases). The nodules with poorly-defined margin in ultrasonographic findings showed higher probability of malignancy as 63.6% (7/11cases) than the nodules with well -defined margin as 26.5%(9/34 cases) (p=0.025). The nodules with calcification in ultrasonographic findings were represented to high probability of malignancy as 70.6%(12/17cases) compared to those without calcification as 29.4%(10/34cases) (p=0.005). The differency between ultrasonic and histopathological diagnosis was high in solid nodules(33%), 3-4cm sized nodules (28.6%) and mixed echogenecity(27.3%) whereas low in complex nodules with cystic and solid nature(4.8%), 2-3 cm sized nodules(8.3%) and pooly defined margin(9.1%). The accuracies of sonography in differentiating malignacy from benign thyroid nodules were 7.1% of false positivity, 39.1% of false negativity, 60.9% of sensitivity, 92.9% of specificity and 78.4% of accuracy. Conclusion: Sonographic examination was relatively excellent test as a preoperative diagnostic tool in thyroid nodular diseases when detailed checklists were applied such as internal consistency, multiplicity of nodules, nodular ehogenicity, nodular capsule or margin and calcification of nodules.

  • PDF

Scientific Investigation for Conservation Methodology of Bracket Mural Paintings of Daeungjeon Hall in Jikjisa Temple (직지사 대웅전 포벽화 보존방안을 위한 과학적 조사)

  • Lee, Hwa Soo;Kim, Seol Hui;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.34 no.2
    • /
    • pp.107-118
    • /
    • 2018
  • This report does studied for making the method of conserving bracket murals in Daeungjeon of Jikjisa Temple, through the scientific way. Results of evaluated the conservation status at the braket mural paintings, most serious damage is structural damage like cracks, breakage, and delamination. After optical investigation, a characteristic point wasn't found such as underdrawing or traces of a coat of paint. The ultrasonic examination speed by each wall painting was measured from about 195.8 m/s to 392.7 m/s, according to the location of the surface, and it was able to compare the surface properties according to the location. In Infrared-thermal image measurement shows that wall layer separation and paint layer delamination are closely detected, therefore it was able to judge of damage on the objective way. Material analysis revealed that the walls were made by sand and weathering soil. The wall layer combined sand with less than fine sand size by nearly 5:5, and the finishing layer was found to have mixed medium sand and fine sand at approximately 6:4 rates. However, In case of finishing layer, mixing ratios of sizes less than very fine sand were found to be significantly lower than wall. Therefore, it is estimated that the plysical damage such as the separation between the layers of the walls created in the braket mural paintings, is continuously caused by changes in the internal stresses and volume ratio caused by the density differences between the wall and the finishing layers.

A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province (조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 -)

  • Yang, Jeong-Hwa;Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.63-69
    • /
    • 2006
  • In diagnostic ultrasound, the quality of image affect to diagnose. To maintain suboptimal imaging uniformly, Quality Assurance of Ultrasound equipment should take periodically. This is article about examination the quality of image in diagnostic ultrasound to understand conditions of probes in hospitals. There is comparative study of convex and linear probes on ultrasound using tissue-mimicking phantom included simulated cysts, echogenic structures. The ultrasonic attenuation coefficient versus frequency of 0.5 dB is representative of normal liver and 0.7 dB is representative of fatty liver condition in ultrasound phantom. There are results of convex probe, 0.5 dB, vertical group, cystic masses, high contrast masses are mostly shown but 0.7 dB, mid level in vertical group, cystic masses and high contrast masses are nearly visible. In linear probe, 0.5 dB, mid level in vertical group, two or four of them are shown in cystic masses and high contrast masses but there are not visible in 11 of cases. 0.7 dB, there are mostly appear under 6 in vertical group, two or four of them show in cystic masses and high contrast masses and there are not shown in 40 of cases, besides. Linear probes in fatty liver condition of ultrasound instrument are not good in the quality of image practically. So there needs to be replace and fix of probes. Actually management of ultrasound probes is inadequate in hospitals. So if there are program of evaluation to check probes periodically in hospitals from establishment of the ultrasound equipment, there will get better image and have a suitable condition of instruments further more.

  • PDF

Image Quality Analysis According to the of a Linear Transducer (선형 탐촉자에서 관심 시각 영역 변화에 따른 화질 분석)

  • Ji-Na, Park;Jae-Bok, Han;Jong-Gil, Kwak;Jong-Nam, Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.975-984
    • /
    • 2022
  • Since a linear transducer has an area of interest equal to the length of the transducer, the area of interest can be expanded using the virtual convex function installed in the device.However, it was thought that the change in the direction of the ultrasonic sound velocity according to the change in the visual area of interest would affect the image quality, so this was objectively confirmed. For this study, image evaluation and SNR·CNR of the phantom for ultrasound quality control were measured. As a result, in the phantom image evaluation, both images were able to identify structures in functional resolution, grayscale, and dynamic range. However, it was confirmed that the standard image was excellent in the reproducibility of the size and shape of the structure. As a result of SNR·CNR evaluation, SNR·CNR of most trapezoidal images was low, except for structures at specific locations. In addition, through the statistical analysis graph, it was further confirmed that the SNR and CNR for each depth decreased as the size of the cystic structure decreased. Through this study, it was confirmed that the use of the function has the advantage of providing a wide visual area of interest, but it has an effect on the image quality. Therefore, when using the virtual convex function, it is judged that the examiner should use it in an appropriate situation and conduct various studies to acquire high-quality images and to improve the understanding and proficiency of the equipment.

A Study on Shear Bond Strength of Core-veneer Interface for Bilayered all Ceramics (Bilayered all Ceramics에서 Core와 Veneer 계면의 전단결합강도에 관한 연구)

  • Jung, Yong-Su;Lee, Jin-Han;Lee, Jae-In;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.231-242
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the bond strength of the core-veneer interface in all ceramic systems. Material and Methods: The all ceramic systems tested with their respective veneer were IPS Empress 2 with IPS Eris, IPS e.max Press with IPS e.max Ceram and IPS-e.max ZirCAD with IPS e.max Ceram. Cores (N=36, N=12/group, diameter: 10mm, thickness: 3mm) were fabricated according to the manufacturer's instruction and cleaned with ultrasonic cleaner. The veneer(diameter: 3mm, thickness: 2mm) were condensed in stainless steel mold and fired on to the core materials. After firing, they were again ultrasonically cleaned and embedded in acrylic resin. The specimens were stored in distilled water at $37^{\circ}C$ for 1 week. The specimens were placed in a mounting jig and subjected to shear force in a universal testing machine(Z020, Zwick, Germany). Load was applied at close to the core-veneer interface as possible with crosshead speed of 1.00mm/min until failure. Average shear bond strengths(MPa) were analyzed with a one-way analysis of variance and the Tukey test(${\alpha}=.05$). The failed specimens were examinated by scanning electron microscopy(JSM-6360, JEOL, Japan). The pattern of failure was classified as cohesive in core, cohesive in veneer, mixed or adhesive. Results: The mean shear bond strength($MPa{\pm}SD$) were IPS e.max Press $32.85{\pm}6.75MPa$, IPS Empress 2 $29.30{\pm}6.51MPa$, IPS e.max ZirCAD $28.10{\pm}4.28MPa$. IPS Empress 2, IPS e.max Press, IPS e.max ZirCAD were not significantly different from each others. Scanning electron microscopy examination revealed that adhesive failure did not occur in any all ceramic systems. IPS Empress 2 and IPS e.max Press exhibited cohesive failure in both the core and the veneer. IPS e.max ZirCAD exhibited cohesive failure in veneer and mixed failure.