• Title/Summary/Keyword: Ultrasonic Energy

Search Result 650, Processing Time 0.023 seconds

A Study on the Various Characteristics of Ultrasonic-Energy-Added W/O Type Emulsified Fuel ( I ) - attaching importance to stability and spray characteristics - (초음파에너지 조사 W/O type 유화연료의 제반특성에 관한 연구(I) - 안정성 및 분무특성을 중심으로 -)

  • Kim, Yong-Cheol;Song, Yong-Sik;Ryu, Jeong-In
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.22-28
    • /
    • 2004
  • This study is concerned about the characteristics of ultrasonic-energy-added W/O type emulsified fuel. The distilled water was mixed with diesel oil by using ultrasonic energy fuel feeding system and then the SMD of sprayed droplets was measured to find out atomization characteristics of emulsified fuel by using the Malvern 2600 system. The capacitance value was measured to verify stability of the same specimen by using the digital LCR meter, EDC1630 additionally. The main results are as follows; 1) The more measuring distance increases between one hole nozzle tip and analyser bearm, the more SMD increases. 2) The more water content increases, the more capacitance value increases depending on the time. Main Parameters of the study are the amount of water content $0{\sim}30%$ by 5% in emulsified fuel, and the measurement distance, $20{\sim}140mm$ by 10mm or 20mm between nozzle tip and analyser beam.

  • PDF

PFC Ultrasonic Decontamination Efficiency on the Various Types of Metal Specimens (금속 시편 형태에 따른 PEC 초음파 제염 성능)

  • Won Hui-Jun;Kim Gye-Nam;Jung Chung-Hun;Park Jin-Ho;Oh Won-Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.293-300
    • /
    • 2005
  • Ultrasonic decontamination of the type 304 stainless steel specimen loosely contaminated with $Eu_2O_3$ powders was investigated. Decontamination factors (DFs) by the three kinds of ultrasonic media such as water, pure PFC (Pefluorocarbon, $C_7F_{16}$) and a mixed solution of $99.9\;vol\%\;PFC\;and\;0.1\;vol\%$ anionic surfactant were determined. The determined DF values were 20, 50 and 200, respectively. This significant difference in the decontamination factors for the different decontamination solution was well explained by the surface tension of the media as well as the interaction between the positively charged surface of $Eu_2O_3$ powders and the anionic surfactant. Ultrasonic decontamination behavior of the loosely contaminated metal specimens such as plate, pipe, welding specimen and crevice specimen in the mixed solution of PFC and anionic surfactant was also investigated. The contaminants were completely removed for the tested specimens except for the longest specimen. For 6-cm long pipe specimen, however, $98.5\%$ of the contaminants were removed.

  • PDF

Ultrasonic Cavitation Behavior and its Degradation Mechanism of Epoxy Coatings in 3.5 % NaCl at 15 ℃

  • Jang, I.J.;Jeon, J.M.;Kim, K.T.;Yoo, Y.R.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.26-36
    • /
    • 2021
  • Pipes operating in the seawater environment faces cavitation degradation and corrosion of the metallic component, as well as a negative synergistic effect. Cavitation degradation shows the mechanism by which materials deteriorate by causing rapid change of pressure or high-frequency vibration in the solution, and introducing the formation and explosion of bubbles. In order to rate the cavitation resistance of materials, constant conditions have been used. However, while a dynamic cavitation condition can be generated in a real system, there has been little reported on the effect of ultrasonic amplitude on the cavitation resistance and mechanism of composites. In this work, 3 kinds of epoxy coatings were used, and the cavitation resistance of the epoxy coatings was evaluated in 3.5% NaCl at 15 ℃ using an indirect ultrasonic cavitation method. Eleven kinds of mechanical properties were obtained, namely compressive strength, flexural strength and modulus, tensile strength and elongation, Shore D hardness, water absorptivity, impact test, wear test for coating only and pull-off strength for epoxy coating/carbon steel or epoxy coating/rubber/carbon steel. The cavitation erosion mechanism of epoxy coatings was discussed on the basis of the mechanical properties and the effect of ultrasonic amplitude on the degradation of coatings.

An Ultrasonic Application with High Frequency for the Efficiency Elevation of the Hydrogen Fuel Production (On the Pole Interval and the Temperature) (수소연료 생산의 효율향상을 위한 고주파수 초음파 응용 (극간격과 온도 중심으로))

  • Song, Min-Geun;Son, Seung-Woo;Ju, Eun-Sun
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.2
    • /
    • pp.127-134
    • /
    • 2002
  • A Study on the application of ultrasonic with high frequency is carried out as a plan to rise the efficiency of the hydrogen fuel production in an electrolysis of water. KOH is selected as an electrolyte and concentrations are 0 %, 10 %, 20 %, and 30%. The solvent is city water. A measurable device of buoyancy by an electronic balance and a measurable device of voltage with a sensor of pressure are planned newly as a measuring device to measure the quantity of hydrogen production. An ultrasonic transducer with high frequency of 2 MHz is selected to give them the ultrasonic forcing. In results, it is clarified that ultrasonic influences the decrease of overpotential in the electrolytic solution. And basic data according to the pole interval and the temperature are obtained.

The Effect of Ultrasonic Vibration on Heat Transfer Augmentation of Forced Convective Flow in Circular Pipes (초음파 진동이 관내 강제대류 유동의 열전달 증진에 미치는 영향)

  • Jeong Ji Hwan
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.275-280
    • /
    • 2004
  • Augmentation of heat transfer by ultrasonic vibration in pipes are investigated. Measurements of convective heat transfer coefficients on circular pipe walls are made with and without ultrasonic vibration applied to water. These data are compared with each other to quantify the effects of ultrasonic vibration on heat transfer enhancement. Numerical analysis has been also performed in order to extend the ranges of examined temperature and flow rate. FLUENT Ver.6.1 is used to simulate velocity and temperature fields and evaluate heat transfer coefficient with and without ultrasonic vibration. The results show that the ultra- sonic vibration enhances the Nusselt number of forced convection flow and the increase rate strongly depends on flow rate.

Influence of Local Ultrasonic Forcing on a Turbulent Boundary layer (국소적 초음파 가진이 난류경계층에 미치는 영향)

  • Park, Young-Soo;Sung, Hyung-Jin
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.17-22
    • /
    • 2005
  • An experimental study was carried out to investigate the effect of local ultrasonic forcing on a turbulent boundary layer. Stereoscopic particle image velocimetry (SPIV) was used to probe the characteristics of the flow. A ultrasonic forcing system was made by adhering six ultrasonic transducers to the local flat plate. Cavitation which generates uncountable minute air-bubbles having fast wall normal velocity occurs when ultrasonic was projected into water. The SPIV results showed that the wall normal mean velocity is increased in a boundary layer dramatically and the streamwise mean velocity is reduced. The skin friction coefficient ($C_{f}$) decreases $60\%$ and gradually recovers at the downstream. The ultrasonic forcing reduces wall-region streamwise turbulent intensity, however, streamwise turbulent intensity is increased away from the wall. Wall-normal turbulent intensity is almost the same near the wall but it increases away from the wall, In tile vicinity of the wall, Reynold shear stress, sweep strength and production of turbulent kinetic energy were decreased. This suggests that the streamwise vortical structures are lifted by ultrasonic forcing and then skin friction is reduced.

  • PDF

A Study on the Fluid Flew with Ultrasonic Forcing by PIV Measurement (초음파가 가진된 유체유동의 PIV계측에 의한 연구)

  • 주은선;이영호;나우정;정진도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1281-1290
    • /
    • 2001
  • A study on the fluid flow with ultrasonic forcing is carried out to obtain data for the turbulence enhancement. A large water tank is made of the transparent acrylic plates and a horizontal flow field is given by setting two acrylic tubes to face mutually on a horizontal line. A 2-dimensional PlV system which is composed of a continuous-output 4W Argon-ion laser, a high-speed video camera, a PC based by an image grabber and a high resolution monitor is used to investigate characteristics of the complex turbulence flow field. And a 2MHz ultrasonic transducer is used fur ultrasonic vibration forcing. Some experiments are carried out at Reynolds numbers of 2,000 and 4,000 and at 7 angles of ultrasonic incidence. In results, the flew velocity vector distribution, kinetic energy and turbulence intensity in both cases of with and without ultrasonic forcing are examined, compared and discussed by using PIV measurement. It is clarified that the ultrasonic forcing into flow field is valid to obtain the turbulence enhancement.

  • PDF

Effect on Copper Recovery by Ultrasonic Energy during Cementation Reaction from Copper-contained Waste Etching Solution (구리 함유 폐에칭액의 시멘테이션 반응 시 구리 회수에 미치는 초음파 에너지의 영향)

  • Kim, Boram;Jang, Dae-Hwan;Kim, Dae-Weon;Chae, Byung-Man;Lee, Sang-Woo
    • Resources Recycling
    • /
    • v.31 no.4
    • /
    • pp.34-39
    • /
    • 2022
  • In this study, effects of ultrasonic energy on the cementation reaction and copper recovery rate were investigated for different types of iron samples, such as plate, chip, and powder, for recovering copper from waste etchant, which contained ~3.5% copper. The cementation reaction using the ultrasonic energy was more effective than the simple stirring reaction, with the former exhibiting a high copper recovery rate than the latter for the same time interval. When cementation was performed for 25 min with ultrasonic treatment, rather than simple stirring, the copper recovery rate of the plate, chip, and powder improved from 7.0% to 12.0%, 14.0% to 46.1%, and 41.9% to 77.2%, respectively. Therefore, the use of ultrasonic energy could detach the copper recovered by the cementation reaction from the surface of the iron samples, thereby increasing the copper recovery rate. Owing to the use of ultrasonic energy, the copper recovery rate increased by 2-6 times, and the recovered copper exhibited a decreased particle size compared to that obtained via simple stirring.

Influence of Dislocation Substructure on Ultrasonic Velocity under Tensile Deformation

  • Kim, C.S.;Lissenden, Cliff J.;Kang, Kae-Myhung;Park, Ik-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.477-482
    • /
    • 2008
  • The influence of dislocation substructure of metallic materials on ultrasonic velocity has been experimentally investigated. The test materials of pure Cu, brass (Cu-35Zn), 2.25Cr-1Mo steel, and AISI 316 with different stacking fault energy (SFE) are plastically deformed in order to generate dislocation substructures. The longitudinal wave velocit $(C_L)$ decreases as a function of tensile strain in each material. The $C_L$ of Cu-35Zn and AISI 316 decreases monotonously with tensile strain, but $C_L$ of Cu and 2.25Cr-1Mo steel shows plateau phenomena due to the stable dislocation substructure. The variation of ultrasonic velocity with the extent of dislocation damping and dislocation substructures is discussed.

Micro Ultrasonic Elliptical Vibration Cutting (II) Ultrasonic Micro V-grooving Using Elliptical Vibration Cutting (미세 초음파 타원궤적 진동절삭 (II) 타원진동 절삭운동을 이용한 미세 홈 초음파 가공)

  • Kim Gi Dae;Loh Byoung-Gook;Hwang Kyung-Sig
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.198-204
    • /
    • 2005
  • For precise micro V-grooving, ultrasonic elliptical vibration cutting (UEVC) is proposed using two parallel piezoelectric actuators, which are energized by sinusoidal voltages with a phase difference of 90 degrees. Experimental setup is composed of stacked PZT actuators, a single crystal diamond cutting tool, and a precision motorized xyz stage. It is found that the chip formed in the process of UEVC is discontinuous because of the periodic contacts and non-contacts occurring between the tool and workpiece. It is experimentally observed that the cutting force in the process of UEVC significantly reduces compared to the ordinary non-vibration cutting. In addition, the creation of burr during UEVC is significantly suppressed, which is attributable to the decrease in the specific cutting energy.