• 제목/요약/키워드: Ultrasonic Doppler

검색결과 82건 처리시간 0.038초

초음파 측정용 레이저 도플러 진동계의 제작에 관한 연구 (Basic Study for the fabrication of Laser Doppler Vibrometer for the Detection of Ultrasonic)

  • 김승종;김명선;김호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2195-2197
    • /
    • 2000
  • In order to detect the ultrasonic that is generated by the partial discharge of the heavy electric machinery a Laser Doppler Vibrometer (LDV) is developed. A Michelson type interferometer which employed heterodyne signal process technique is built to measure the frequency and amplitude of vibration. The output signal of the fast photodetector is a frequency modulated signal centered at 40 MHz. The signal from the detector is amplified and converted to intermediate frequency centered at 1 MHz after mixing process. The voltage output that is proportional to the velocity of the moving surface(PZT) is obtained using PLL. The spectrum of the FM signal is analyzed and integration method was introduced to obtain amplitude information. This LDV can be used to measure the vibration of MEMS devices, automobiles, HDD and CDP.

  • PDF

비침투적인 생체 경조직의 음향진단을 위한 기초실험 (A Method for Non-invasive Diagnosis of bone by Measuring Phase Velocity)

  • 박무훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권1호
    • /
    • pp.91-97
    • /
    • 1999
  • 본 논문에서는 기술적으로 실용화가 비교적 용이(容易)한 저주파대역에서, 뼈의 기계적인 성질을 계측하기 위한 진단법에 대하여 연구를 하고 있다. 종래의 연구에서는 여러 가지 문제점을 해결하고 보다 정확하게 뼈를 진단하기 위하여 초음파도플러법을 이용해서 In-vivo에서 측정하는 방법을 제안한다. 측정한 속도분포를 분포정수선로모델에 적용해 구해진 위상속도를 이용해서 종파의 전파속도를 구한다.

  • PDF

초음파 도플러 신호를 이용한 음성 합성 (Speech synthesis using acoustic Doppler signal)

  • 이기승
    • 한국음향학회지
    • /
    • 제35권2호
    • /
    • pp.134-142
    • /
    • 2016
  • 본 논문에서는 40 kHz 초음파 신호를 입 주변에 쏘고, 되돌아오는 초음파 신호를 이용해 음성신호를 합성하는 방법을 소개하고 성능을 평가하였다. 발성하고 있는 입주변에 초음파를 방사하게 되면, 입술, 턱, 뺨 등의 움직임으로 인한 변위로 도플러 현상이 발생하고, 이에 따라 반사 신호에는 본래의 주파수 성분과는 다른 도플러 주파수가 관찰되는데, 본 논문에서는 이러한 도플러 주파수를 이용하여 음성 파라메터를 추정하도록 하였다. 음성합성에 앞서서 초음파 도플러 신호와 음성 신호 간의 상관관계를 각 주파수 별로 분석하였으며, 이로부터 초음파 도플러 신호를 이용한 음성 신호의 합성 가능성을 살펴보았다. 변환에는 초음파 도플러의 정적, 동적 특성을 함께 반영한 특징 변수를 사용하였으며 결합-혼합 가우시안 기법을 이용하여 음성 파라메터로 변환하였다. 5명의 피 실험자를 이용한 음성 합성 실험에서 필터뱅크 에너지 값을 초음파신호의 특징변수로, LPC(Linear Predictive Coefficient) 켑스트럼 계수를 음성 변수로 사용하는 경우 가장 우수한 변환 성능을 나타내었다. 음성신호에서 추출한 여기신호를 이용하여 합성음을 생성하고, 이를 청취하였을 때 72.2 %의 평균 인식율이 얻어짐을 확인할 수 있었다.

펄스 초음파 도플러 속도계의 제작에 관한 연구 (Construction of Ultrasound Pulsed Doppler Velocimeter)

  • 현석봉;김수용;이재수
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.25-39
    • /
    • 1994
  • 심장 벽의 운동속도와 혈관내 혈구의 유속을 측정하기 위해, 단일 채널 3.1MHz 펄스 도플러 속도계를 제작하였다. 도플러 속도계에 사용된 초음파 펄스의 폭과 펄스 반복주파수(PRF)는 각각 1$\mu$s과 6kHz이고, 후방 산란된 반향신호의 도플러 편이는 완전간섭성(coherent) 복조방식을 이용하여 위상 측정기에 감지된다. 위상 측정기의 출력신호로부터 레인지 게이트와 샘플 홀더, 대역여파기를 이용하여 작은 영역내에 있는 초음파 산란체의 평균속도에 해당하는 도플러 신호가 얻어진다. 도플러 신호의 평균 주파수는 영점교차의 카운터에 의해 측정되며 시간의 함수로 산란체의 순간 속도를 디스플레이한다. 채널 수와 거리 분해능을 증가시키면 혈관내의 혈류속도 분포도와 총 유량 그리고 혈류가속도를 측정할 수 있다.

  • PDF

A Comparison of Ultrasonic Doppler and Oscillometric Methods in Systemic Blood Pressure Measurement of Dogs

  • Gang, Ho-min;Song, Joong-Hyun;Cho, Kyu-Woan;Jung, Dong-In
    • 한국임상수의학회지
    • /
    • 제33권6호
    • /
    • pp.321-324
    • /
    • 2016
  • The present study compared two indirect blood pressure methods at thoracic limb, pelvic limb, and coccygeal sites. For measurement of blood pressure, 48 client-owned dogs in a clinical setting were used. When comparing the results obtained by doppler and oscillometric methods, there were significant differences in blood pressure of the thoracic and pelvic limbs. The Doppler machine produced significantly higher blood pressure value than oscillometry measured at thoracic and pelvic limbs. The difference in blood pressure between the two methods was not significant when measured in the tail. Comparison of blood pressure measured at three different sites by doppler, blood pressure measured at pelvic limb was higher than at thoracic limb and tail. In case of oscillometry, there were no significant differences between the three sites. The results of this study indicate that mechanical and positional differences were existed in blood pressure measurements at the canine thoracic limb, pelvic limb and tail.

도플러센서 LED 조명등을 위한 절전형 컨버터 개발 (The Development of Energy-Saving Converter for Doppler Sensor LED Lights)

  • 박양재
    • 디지털융복합연구
    • /
    • 제13권9호
    • /
    • pp.251-257
    • /
    • 2015
  • 최근에는 물체의 움직임을 감지하는 기술은 에너지 절약, 충돌방지, 자동문 개폐 등 다양한 분야에 적용되고 있다. 도플러 센서는 기존의 적외선 센서, 초음파 센서들의 문제점을 보완할 수 있는 센서로 온도, 잡음, 먼지 등과 같은 주변 환경에 큰 영향을 받지 않는다. 본 논문에서는 24시간 점등되어 있는 LED조명등을 도플러 센서로 물체가 감지 될 때만 ON, 없을 때는 OFF상태로 전환하고, LED조명등의 조도를 2단으로 제어하는 컨버터를 개발하였다. 개발된 도플러 센서 모듈과 절전형 제어 컨버터를 주차장등에 적용하여 절전 효과를 증명하였다.

Rail Inspection Using Noncontact Laser Ultrasonics

  • Kim, Nak-Hyeon;Sohn, Hoon;Han, Soon-Woo
    • 비파괴검사학회지
    • /
    • 제32권6호
    • /
    • pp.696-702
    • /
    • 2012
  • In this study, a noncontact laser ultrasonic system is proposed for rail defect detection. An Nd-Yag pulse laser is used for generation of ultrasonic waves, and the corresponding ultrasonic responses are measured by a laser Doppler vibrometer. For the detection of rail surface damages, the shape of the excitation laser beam is transformed into a line. On the other hand, a point source laser beam is used for the inspection of defects inside a rail head. Then, the interactions of propagating ultrasonic waves with defects are examined using actual rail specimens. Amplitude attenuation was mainly observed for a surface crack, and reflections were most noticeable from an internal damage. Finally, opportunities and challenges associated with real-time rail inspection from a high-speed train are discussed.

하드디스크 서스펜션의 초음파 진동측정 기술 (AN ULTRASONIC METHOD FOR VIBRATION MEASUREMENT OF THE SUSPENSION IN HARD DISK DRIVES)

  • 하완;김노유
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.720-725
    • /
    • 2000
  • A new ultrasonic pulse-echo technique was developed and described for vibration measurement of the suspension assembly in hard disk drives. The method is based upon the difference in magnitude of two consecutive reflection waves from a moving object(suspension), while the traditional ultrasonic vibrometer uses the phase shift of the reference wave and the reflection wave. A cone-shape delay line is designed to access the small structure. A simple mathematical model is presented and analyzed with experimental results to show the feasibility of the method. The advantages of this ultrasonic vibration measurement method are relatively high resolution, low cost, and ease of implementation comparing with the Laser Doppler vibrometer.

  • PDF

PIV계측을 이용한 난류유동의 증진을 위한 초음파 적용 (Ultrasonic Applications for the Enhancement of Turbulence Flow by using the PIV Measurement)

  • 박영호;최우창;구자훈;송민근;주은선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.633-638
    • /
    • 2000
  • Ultrasonic applications for the enhancement of turbulence flow by using the PIV measurement were carried out according to the angle of the ultrasonic oscillator, materials of the reflector and each section when ultrasonic is reflected several times. Angles of the ultrasonic oscillator such as $30^{\circ},\;45^{\circ},\;60^{\circ},\;90^{\circ},\;120^{\circ},\;135^{\circ}$ and $150^{\circ}$ were selected, and turbulent intensities were compared at Reynolds No. 2,000 and 4,000. Materials of the reflector such as wood, acryl, iron and glass were selected, and time mean velocity vector and turbulent intensity were compared at Reynolds No. 4,000. The zone which was observed was selected from first section to fourth section when ultrasonic was reflected several times. Every data such as time mean velocity vector and time mean turbulent intensity which was obtained by PIV measurement was examined, compared and discussed at Reynolds No. 2,000 and 4,000 to know the degree of turbulence enhancement in each case.

  • PDF

속도 벡터 영상 방법 (Velocity Vector Imaging)

  • 권성재
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권1E호
    • /
    • pp.11-27
    • /
    • 2010
  • Nowadays, ultrasound Doppler imaging is widely used in assessing cardiovascular functions in the human body. However, a major drawback of ultrasonic Doppler methods is that they can provide information on blood flow velocity along the ultrasound beam propagation direction only. Thus, the blood flow velocity is estimated differently depending on the angle between the ultrasound beam and the flow direction. In order to overcome this limitation, there have been many researches devoted to estimating both axial and lateral velocities. The purpose of this article is to survey various two-dimensional velocity estimation methods in the context of Doppler imaging. Some velocity vector estimation methods can also be applied to determine tissue motion as required in elastography. The discussion is mainly concerned with the case of estimating a two-dimensional in-plane velocity vector involving the axial and lateral directions.