• 제목/요약/키워드: Ultrasonic Attenuation Coefficient

검색결과 84건 처리시간 0.025초

Al/Epoxy 이종재 접합 계면의 초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficients on Interfaces of Al/Epoxy Bonded Dissimilar Materials)

  • 박성일;정남용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1109-1114
    • /
    • 2003
  • The initial crack often occurs on the bonded interface and it is the general cause of the interface fracture. It is very significant to establish the measurement method of interfacial crack by applying the ultrasonic technology into the interface of bonded dissimilar materials. In this paper, the interfacial crack length was measured by ultrasonic attenuation coefficient in the Al/Epoxy bonded dissimilar materials of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental and Ripling's equation measurement of compliance. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the experimental results, a measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficient)

  • 정남용;박성일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.340-345
    • /
    • 2003
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the relation between crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the results of experiments, the measurement method of crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficient)

  • 정남용;박성일
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.386-393
    • /
    • 2004
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.

DETECTION OF INTERFACIAL CRACK LENGTH BY USING ULTRASONIC ATTENUATION COEFFICIENTS ON ADHESIVELY BONDED JOINTS

  • Chung, N.Y.;Park, S.I.
    • International Journal of Automotive Technology
    • /
    • 제5권4호
    • /
    • pp.303-309
    • /
    • 2004
  • In this paper, an interfacial crack length has been detected by using the ultrasonic attenuation coefficient on the adhesively bonded double-cantilever beam (DCB) joints. The correlations between energy release rates which were investigated by experimental measurement, the boundary element method (BEM) and Ripling's equation are compared with each other. The experimental results show that the interfacial crack length for the ultrasonic attenuation coefficient and energy release rate increases proportionally. From the experimental results, we propose a method to detect the interfacial crack length by using the ultrasonic attenuation coefficient and discuss it.

이종 접합부재의 두께 변화에 따른 초음파 산란 보정에 의한 계면균열 길이의 측정 (Measurement of Interfacial Crack Length by Ultrasonic Scattering Compensation Depending on Thickness Variations of Bonded Dissimilar Components)

  • 정남용
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.67-75
    • /
    • 2006
  • In this paper, the compensation of ultrasonic scattering on interface crack depending on thickness variations of A1/Epoxy bonded dissimilar components was applied to improve measuring accuracy by using ultrasonic attenuation coefficient. The optimum conditions of theoretical value and experimental measuring accuracy by the ultrasonic method in A1/Epoxy bonded dissimilar components have been investigated. From the experimental results, the measurement method of interfacial crack lengths by using ultrasonic attenuation coefficient was proposed and discussed. After the ultrasonic scattering compensation depending on thickness variations of bonded dissimilar components was carried out, the measuring accuracy of interfacial crack length was improved by 5%.

접착부재의 초음파 감쇠계수에 의한 계면균열 길이의 측정 (Measurement of Interfacial Crack Length by Ultrasonic Attenuation Coefficients on Adhesively Bonded Components)

  • 정남용;박성일
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.130-137
    • /
    • 2004
  • The ultrasonic attenuation coefficients were measured by interfacial crack length in the adhesive components of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental measurement of compliance. The numerical analysis by the boundary element method(BEM) and Ripling's equation was investigated. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. A measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

간 병변의 정량화를 위한 초음파 영상 신호의 감쇄상수 추정 (Estimation of Attenuation Coefficient based on Ultrasonic Image for quantification of the Liver Diseases)

  • 우광방;신동호;이성모;신영민;이노성;오성권
    • 대한전자공학회논문지
    • /
    • 제25권1호
    • /
    • pp.49-55
    • /
    • 1988
  • To provide a quantitative parameter of evaluating diagnosis of the liver diseases accurately, the ultrasonic attenuation coefficient was estimated from liver phantoms, 15 normal human livers and 30 liver disease patients. Two kind of phantoms(No.1: 1552m/s, No.2: 1562m/s) which have velocity (1560m/s) similar to that in human liver were constructed and their ultrasonic attenuation coefficients were determined. In this paper the spectral-shift approach and spectral-difference approach were used for estimating ultrasonic attenuation coefficient, \ulcornerdB/Cm.MHz). These two approaches were utilized to esitmate for 15 normal humans without any liver disease and 30 liver disease patients. The results indicate that the two types of phantoms produce the value of near the suggested value of 0.5 and the attenuation coefficients of hepatoma, normal liver, corrhosis, fatty liver and hepatitis show decreasing value in order named, suggesting that the present study can be of clinical value incorrelating the estimated attenuation coefficidents with the liver diseases.

  • PDF

이종 접합부재의 두께 변화에 따른 계면균열의 초음파 산란 보정 (Ultrasonic Scatter and Compensation of Interfacial Crack due to Thickness Variation of Dissimilar Bonded Components)

  • 박성일;정남용;진윤호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.25-30
    • /
    • 2004
  • In this paper, the compensation of interfacial scatter due to adhesive layer and adherend thickness ratio variation was applied to improve measuring precision by calculating ultrasonic attenuation coefficient in the Al/Epoxy dissimilar bonded components. The optimum condition of theoretical value and experimental measuring accuracy by the ultrasonic method in the Al/Epoxy dissimilar bonded components have been investigated. From the experimental results, we proposed a measurement method of the interfacial crack lengths by the ultrasonic attenuation coefficient and discussed it.

  • PDF

SCM440 강의 결정입도와 조직의 변화에 따른 초음파 감쇄 (Ultrasonic Attenuation due to the Changes of Grain Size and microstructure of SCM440 Steel)

  • 박은수;강계명;김선진;장순식
    • 한국재료학회지
    • /
    • 제3권6호
    • /
    • pp.585-592
    • /
    • 1993
  • 여러 온도에서 급냉 및 템퍼링시킨 SCM440강을 이용하여 결정입도와 조직의 변화가 초음파감쇄에 미치는 영향에 관하여 연구하였다. 초음파감쇄는 주로 결정립에 의한 산란에 기인하였으며 감쇄계수는 결정립의 크기가 클수록 증가하였으나 템퍼링 시킨 조직의 경우 템퍼링온도가 높아질수록 감쇄계수는 감소하는 것을 알 수 있었다. 주파수의 의존성은 직선적인 log-log 관계를 가지며 Roney의 식과 비례하는 것으로 조사되었다.

  • PDF

Homomorphic Deconvolution 법에 의한 초음파 감쇄정수 추정 (Estimation of Ultrasound Attenuation Coefficient by Homomorphic Deconvolution Method)

  • 홍승홍;허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제5권1호
    • /
    • pp.39-46
    • /
    • 1984
  • In order to improve the performance of ultrasonic diagnostic equipment, it is important to development the signal processing considering the ultrasonic properties of biological medium and propagation mechanism in tissue. Attenuation coefficient is not only important factor to analyze propagation properties, but also it is significant to estimate it in view of tissue characterization, so we show one of the method to estimate attenuation coefficient of biological tissue and the results of estimation.

  • PDF