• 제목/요약/키워드: Ultrafiltration system

검색결과 153건 처리시간 0.02초

활성탄과 Membrane을 이용한 수처리효과에 관한연구 (A Study on The Effectiveness of Watertreatment Using Activated Carbons and Membranes)

  • 김영진;김영규;정문호
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.67-72
    • /
    • 1997
  • To evaluate the effectiveness of water treatment using nanofiltration, ultrafiltration, and microfiltration systems, tapwater contaminated by bacteria and nitrate nitrogen was filtered, and then the rates of removal for many kinds of contaminants were comp.ared and investigated. The rates of turbidity removal by these systems are around 80% all of them. However, nanofiltration system is the most effective as hardness removal is 80%, suspended solids 90%, total residual chlorine 90% and nitrate nitrogen 69%. Among nanofiltration, ultrafiltration and microfiltration systems, nanofiltration system is the most stable in flow rate of permeate. Comparing hollow and spiral type of ultrafiltration, microfiltration each, spiral type is more stable than hollow type owing to rinsing effect of brine. The values of pH in ultrafiltration and microfiltration systems are between 7, 0 and 7.5, and that of nanofiltration system is low to 6.2-7.0. The effectiveness of heterotrophic bacteria removal is the most excellent in the nanofiltration system.

  • PDF

Dialysis with ultrafiltration through countercurrently parallel-flow membrane modules

  • Yeh, Ho-Ming;Chen, Chien-Yu
    • Membrane and Water Treatment
    • /
    • 제4권3호
    • /
    • pp.191-202
    • /
    • 2013
  • The application of ultrafiltration operation to the dialysis in countercurrently parallel-flow rectangular membrane modules was investigated. The assumption of uniform ultrafiltration flux was made for operation with slight concentration polarization and declination of transmembrane pressure. Considerable improvement in mass transfer is achievable if the operation of ultrafiltration is applied, especially for the system with low mass transfer coefficient. The enhancement in separation efficiency is significantly increased with increasing ultrafiltration flux, as well as with increasing the volumetric flow rates. Furthermore, increasing the volumetric flow rate in retentate phase is more beneficial to mass transfer than increasing in dialysate phase.

Comparison of different surfactant system for simultaneous removal of nitrate and phosphate using micellar-enhanced ultrafiltration

  • 김보경;백기태;김호정;이율리아;양지원
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.417-421
    • /
    • 2003
  • Three kinds of surfactant systems - cationic surfactant (system 1), combinition of two cationic surfactants (system 2), and combination of two cationic surfactant and non-ionic surfactant (system 3) - for the simultaneous removal of nitrate and phosphate by micellar-enhanced ultrafiltration (MEUF) were investigated. The highest removal efficiencies of nitrate and phosphate were observed in system 2, which were 90 % of nitrate and 72 % of phosphate. The COD of permeate in system 3 was the lowest, because the added non-ionic surfactant made critical micelle concentration (CMC) lower than that of other surfactant systems. In all systems, the flux decline was similar.

  • PDF

가정용 정수시스템의 바이러스 제거 (Removal of Virus in Home Drinking Water Treatment Systems)

  • 김영진;오남순;정문호
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.45-48
    • /
    • 2000
  • Reverse osmosis filtration(RO) system and ultrafiltration(UF) system are principally use for domestic home drinking water treatment systems. The object of this study is to make a comparison between two systems in terms of theirs abilities to remove RNA coilphage QB as an indicator of pathogenic enteroviruses. The virus removal ratio of RO system was 99.999%, which was higher than EPA virus treatment guideline(99.99%). In the course of filtration, removal ratios of sediment filter, pre-carbon filter, reverse osmosis membrane and post-carbon filter were 75.000%, 93.208%, 99.997% and 99.999%, repectively. In case of UF system, virus removal ratio was 99.708%. Removal ratios of sediment filter, pre-carbon filter, post-carbon filter and ultrafiltration membration membrane were 71.038%, 91.530%, 98.283% and 99.708%, respecively, in UF steps. Therefore, RO system is more effective than UF system in virus removal.

  • PDF

Cadmium and zinc removal from water by polyelectrolyte enhanced ultrafiltration

  • Ennigrou, Dorra Jellouli;Ali, Mourad Ben Sik;Dhahbi, Mahmoud;Mokhtar, Ferid
    • Membrane and Water Treatment
    • /
    • 제5권3호
    • /
    • pp.183-195
    • /
    • 2014
  • The efficiency of two metal ions (cadmium, zinc) removal from aqueous solutions by ultrafiltration (UF) and Polymer Enhanced Ultrafiltration (PEUF) processes were investigated in this work. The UF and PEUF studies were carried out using an ultrafiltration tangential cell system equipped with 5.000 MWCO regenerated cellulose. A water-soluble polymer: the polyacrylic acid (PAA) was used as complexant for PEUF experiments. The effects of transmembrane pressure, pH, metal ions and loading ratio on permeate fluxes and metal ions removals were evaluated. In UF process, permeate fluxes increase linearly with increasing pH for different transmembrane pressure, which may be the consequence of the formation of soluble metal hydroxyl complexes in the aqueous phase. In PEUF process, above pH 5.0, the Cd(II) retention reaches a plateau at 90% and Zn(II) at 80% for L = 5. Also, cadmium retention at different L is greater than zinc retention at pH varying from 5.0 to 9.0. In a mixture solution, cadmium retention is higher than zinc for different loading ratio, this is due to interactions between carboxylic groups of PAA and metal ions and more important with cadmium ions.

Rejection Properties of Silica Nanoparticles from Ultrafiltration Membranes

  • Hiromitsu Takaba;Yoshiaki Ito;Nakao, Shin-ichi
    • Korean Membrane Journal
    • /
    • 제5권1호
    • /
    • pp.54-60
    • /
    • 2003
  • The rejection properties and flux rates of silica nanoparticles in ultrafiltration membranes has been investigated. Cross-flow permeation experiments were conducted using polycarbonate track-etch flat membranes with pore sizes of 30 and 50 nm, and a silica nanoparticle solute with particle sizes of 5 and 18 nm with narrow size distributions. The fluxes and rejection factors were investigated at various particle concentrations, cross-flow velocities, pH, and ionic strengths of solution. Even though the size of the silica nanoparticles was much smaller than that of the membrane pores, the observed rejection rates were very high compared with those for a similar-sized polymer (dextran). The observed rejection rate decreased with increasing ionic strength, which implies that the transport mechanism of the silica nanoparticles is significantly influenced by electrostatic repulsion between particles and membranes.

Fouling Mechanism of Microfiltration/Ultrafiltration by Macromolecules and a Suppression Strategy from the Viewpoint of the Hydration Structure at the Membrane Surface

  • Akamatsu, Kazuki;Nagumo, Ryo;Nakao, Shin-ichi
    • 멤브레인
    • /
    • 제30권4호
    • /
    • pp.205-212
    • /
    • 2020
  • This short review focuses on fouling by proteins and macromolecules in microfiltration/ultrafiltration. First, an experimental system that enables investigation of how the extent of the adsorption of proteins and macromolecules on membrane surfaces contributes to a decrease in filtrate flux in microfiltration/ultrafiltration is described. Using this system, a causal relationship - not a correlation - indicating that adsorption results in a decrease in filtrate flux could be clearly demonstrated in some cases. Second, a hydration structure at the membrane surface that can suppress adsorption is discussed, inspired by biomaterial research. In their hydrated states, polymers with low-fouling properties have water molecules with a particular structure. Finally, some successful examples of the development of low-fouling membranes via surface modification using low-fouling polymers are discussed.

Advanced Water Treatment by Tubular Alumina Ceramic Ultrafiltration: Effect of Periodic Water-back-flushing Period

  • Park, Jin-Yong;Lee, Song-Hui
    • Korean Membrane Journal
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2009
  • The periodic water-back-flushing using permeate water was performed to minimize membrane fouling and to enhance permeate flux in tubular ceramic ultrafiltration (UF) system for Gongji stream water treatment in Chuncheon city. The filtration time (FT), which was the water-back-flushing period, 2 min with periodic 15 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume ($V_T$) of 6.35 L. Consequently FT 2 min at back-flushing time (BT) 15 sec could be the optimal condition in advanced UF water treatment of Gongji stream. Then the average rejection rates of pollutants by our tubular ceramic UF system were 99.4% for Turbidity, 31.8% for $COD_{Mn}$, 22.6% for $NH_3$-N and 65.9% for T-P.

응집·한외여과 조합공정에서 플럭스와 선속도가 막오염에 미치는 영향에 관한 연구 (A Study on Membrane Fouling by Flux and Linear Velocity in Coagulation/Ultrafiltration Membrane System)

  • 문성용;이상협;김승현;윤조희
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.429-436
    • /
    • 2005
  • A coagulation/ultrafiltration membrane hybrid system was operated to treat river water with capacity of $0.06m^3/d$. The impact on membrane fouling by flux and linear velocity was investigated. It is known that pressure increase is proportional to flux increase. However, pressure increase was much faster than theoretical value in the pilot plant test. So it was suggested that flux was on important factor in ultrafiltration of continuous operation. Membrane fouling was decreased when linear velocity was increased. This phenomenon was found more obviously without coagulation. With the combination of coagulation and sedimentation, membrane fouling was not reduced conspicuously. Big particles formed during coagulation and sedimentation were destroyed by feed and circulation pumping, which resulted in little effect on membrane fouling reduction. The degree of destruction was similar at various linear velocities. In this study, the hollow fiber membrane was used and the system was operated in pressure type module. In case of the system used in this study, membrane fouling has been affected lightly by linear velocity variation when coagulation pretreatment was applied.

전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로- (The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II))

  • 배기서;이태상;노덕길;홍영기
    • 한국염색가공학회지
    • /
    • 제16권4호
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.