• Title/Summary/Keyword: Ultra Violet(UV)

Search Result 197, Processing Time 0.024 seconds

Study on Compound Humidifier Employing UV-LED using Environmental Life Cycle Assessment (환경전과정평가에 기반한 UV-LED 를 사용한 복합식 가습기에 관한 연구)

  • Choi, Won-Sik;Park, Si-Hyun;Lee, Si-Wang;Jung, Young-Mi;Yi, Hwa-Cho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.9
    • /
    • pp.931-937
    • /
    • 2012
  • In this study, we assessed environmental impacts of compound humidifiers using environmental life cycle assessment and presented the ways to improvements in energy consumption of them. We found eco-design parameters and $CO_2$-eq emissions in each stage of raw material acquisition, manufacturing, transportation, use and disuse in life cycle of the compound humidifiers. The highest $CO_2$ emission is found to be in the stage of use among all stages of life cycle, which is mainly due to power consumption in thermal heating of heating coil for sterilization during humidification. The power consumption and $CO_2$ emission in the stage of use can be reduced to 1/4 and 1/3 at the highest estimate through improvement of sterilization method, respectively. We suggested the replacement of conventional thermal heating coil by ultra violet light-emitting diodes (UV-LED) for sterilization and then presented the experimental results on the sterilization effects of UV-LEDs.

Color Characteristics of 3D-Printed TPU Material Applied with Ultra-Violet Curable Digital Printing Process (자외선 경화형 디지털 프린팅을 이용한 3D 프린팅 TPU 소재의 색채 특성)

  • Lee, Sunhee;Park, Soyeon;Jung, Imjoo;Lee, Jungsoon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.6
    • /
    • pp.1052-1062
    • /
    • 2021
  • This study aims to confirm the possibility of Ultra-Violet (UV)-printed 3D printing materials using thermal polyurethane (TPU) with CMYK colors by applying an eco-friendly UV digital printing process. A UV-printed 3D printing TPU material was prepared with cycles of UV printing and CMYK colors. Dyeability of the 3D TPU samples with cycles of UV printing and CMYK were analyzed for thickness, weight, surface roughness, reflectance, colorimetry, and K/S values. The thickness and weight of 3D-printed TPU samples with cycles of UV printing are increased with overprints from 1 to 5. The surface roughness of 3D-printed TPU samples with increasing UV prints were decreased, meaning that the surface of TPU samples becomes gradually smoother. The reflectance spectra of CMYK UV-printed TPU samples showed the surface reflectance within each characteristic wavelength of CMYK. The 3D-printed TPU samples, subjected to UV printing twice or more, showed low surface reflectance. After examining the L*a*b* of the 3D-printed TPU samples by the cycles of UV printing, the study found that the more UV got printed more than 2 times, the closer the color to each CMYK.

UV emission characteristics of Ne+$N_2$ gas-mixture discharges in AC Plasma Display Panel

  • Baek, Byung-Jong;Hong, Sang-Min;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.586-589
    • /
    • 2002
  • The Ultra Violet(UV) emission characteristics of Neon + Nitrogen gas-mixture discharge was investigated in AC plasma display panel. The firing voltage of Ne+$N_2$ gas-mixture discharge increased with increasing nitrogen concentration. The UV intensity emitted from the gas discharge also increased with increasing nitrogen concentration. The UV efficiency increase with increasing $N_2$ partial pressure at low $N_2$ concentration, and then UV efficiency is saturated at high $N_2$ concentration.

  • PDF

Comparison with Ultra-Violet and Ultra-Sonic Generated by an Insulator at 22.9kV (22.9kV 애자에서 발생한 자외선과 초음파의 비교)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Young-Seog;Jung, Jin-Soo;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.182-183
    • /
    • 2007
  • Recently, diverse techniques for diagnosis on power equipments of the live wire conditions are developed. These techniques are very important that find out the fault signs in power equipments. This paper is Compared with Ultra-Violet and Ultra-Sonic Generated by an Insulator at 22.9kV. The volume of UV images are increased by the square of the applied voltage. The output signals of ultrasonic are detected at about 20kV to 30kV. Hereafter, through the continuous DAQ and analysis, these techniques are the effective method for the improvement of the exciting diagnosis.

  • PDF

Evaluation of Mechanical Property Variation of Epoxy Based Compliant Polymer Concretes Exposed to UV Light (에폭시 기반 연성 폴리머 콘크리트의 자외선 노출에 의한 기계적 물성평가)

  • Roh, In-Taek;Jung, Kyung-Chae;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.27 no.6
    • /
    • pp.236-241
    • /
    • 2014
  • This paper aims to evaluate material property variation of polymer concretes under ultra-violet exposure condition. The components and mixing ratio of the polymer composite specimens were determined by the previous research results. The equivalent UV exposure time was calculated with the consideration of the power of metal halide lamp and maximum 3 years were selected for the experiments. From the tests, it was found that the generated heat during UV exposure affected much the material properties of polymer concrete by means of post cure. As a result, the compressive strength increased and ductility factor decreased.

A Study on Sterilization Characteristics of Elliptical Reactor by Using Xenon Flashlamp and Photocatalyst (Xenon flashlamp와 광촉매를 이용한 타원형 반응기의 살균 특성에 관한 연구)

  • Lee, Dong-Gil;Hong, Ji-Tae;Choi, Kyoung-Hwa;Cha, Jae-Ho;Kim, Hong-Ju;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.559-565
    • /
    • 2009
  • In this paper, we invented a new and unique technique for the sterilization of Escherichia coli(E. coli) in polluted water. We applied a rich ultra-violet(UV) light from pulsed xenon flashlamp and photocatalyst(TiO2) to sterilize E. coli in polluted water. This method based on the use of UV light and photocatalyst is eco-friendly and does not cause secondary pollution. The proposed elliptical reactor is able to concentrate on quartz sleeve coated TiO2 or general quartz sleeve. The primary objective of our research was to determine the important parameters such as pulse repetition rate and input voltage and to know on the sterilizing efficiency of quartz sleeve coated TiO2 and general quartz sleeve. We obtained to achieve 99.999% sterilization in as little as 6 pulses at 800V in case of quartz sleeve coated Ti02, and 10 pulses at 800V in case of general quartz sleeve for 5 minutes. Although transmitted light of quartz sleeve coated TiO2 is deceased, the sterilizing efficiency is increased by 40% than general quartz sleeve. The reason of high sterilizing efficiency is that generated hydroxyl radical(OH) by photocatalyst and is able to concentrate light at a focus by using elliptical reactor.

Measurements of the Benzene Absorption Cross Section in the Range of Ultra Violet (UV) (UV 영역에서 벤젠의 흡수 단면적의 측정)

  • Lee, J.S.;Ryu, S.Y.;Kim, H.H.;Woo, J.C.;Kim, K.B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.922-928
    • /
    • 2006
  • An absolute absorption cross section of benzene was measured with a spectrometer system including a mono-chrometer and a grating in the wavelength region of $240{\sim}280nm$ under the atmospheric pressure and room temperature in the laboratory. A certificated reference benzene gas ($98{\mu}mol/mol$ in $N_2$) was used to measure its absorption cross section. A 710 mm cell with a quartz window and a 150 W Xe arc lamp were employed. The magnitude of absorption cross section of $1.41{\times}10^{-18}cm^2$ was lower than that of the reference spectra ($2.5{\times}10^{-18}cm^2$) of high resolution spectrometer, Total measurement uncertainty was estimated to be 4.0%.

Studies on Application of Sterilization Method Using Ultra Violet Radiation for Liquid Preparations (자외선살균법(紫外線殺菌法)의 액제(液劑)에 대(對)한 응용(應用)의 검토(檢討))

  • Kim, Yong-Bae;Lee, Sang-Hee;Kim, Geon-Chee;Kang, Gun-Il
    • Journal of Pharmaceutical Investigation
    • /
    • v.2 no.1
    • /
    • pp.58-62
    • /
    • 1972
  • The stabillities of taurine, niacinamide, and pyridoxine hydrochloride under exposure to ultra violet radiation in liquid preparations were studied. And sterilization effects for E. coli in both water and liquid preparations were also comparatively evaluated. The above mentioned organic compounds were stable under this experimental conditions and viable count of E. coli reveals that organic compounds dissolved in solution display protective action for microorganisms under UV-irradiation.

  • PDF

Fabrication of Moth-Eye Pattern on a Lens Using Nano Imprint Lithography and PVA Template (나노임프린트 리소그래피와 유연 PVA 템플릿을 이용한 렌즈 표면 moth-eye 패턴 형성에 관한 연구)

  • Bae, B.J.;Hong, S.H.;Kwak, S.U.;Lee, H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.2
    • /
    • pp.59-62
    • /
    • 2009
  • Antireflection pattern, moth-eye structure, was fabricated on lens using Ultra Violet nanoimprint lithography and flexible template. Ni template with conical shaped structure was used as a master template to molding. The flexible poly vinyl alcohol template was fabricated by molding. This poly vinyl alcohol template was used as an imprint template of imprint at lens. Using Ultra Violet nanoimprint lithography and poly vinyl alcohol template, polymer based moth-eye structure was formed on lens and its transmittance was increased up to 94% from 92% at 550 nm wavelength.

Development of an Ultra-Violet Lamp and a Ballast for Ship's Ballast Water Treatment (선박평형수 처리용 자외선 램프 및 안정기 개발)

  • Cheon, Sang-Gyu;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.675-681
    • /
    • 2011
  • In this paper, we dealt with the design and fabrication of a medium pressure ultra-violet (UV) lamp and a magnetic ballast which are main components for ballast water treatment systems (BWTS). To acquire an optimal discharge condition of UV lamp, electrical and optical characteristics depending on the argon gas volume and the amount of mercury were experimentally analyzed. Rated voltage, current and power consumption of a prototype lamp were 490 [V], 8.6 [A] and 4.0 [kW], respectively. UV intensity of the lamp was 15 [%] higher than that of an equivalent lamp which is used in a BWTS. The magnetic ballast was designed in a UI core type through theoretical analysis and simulation. The open voltage and the rated power consumption of the ballast were 920 [V] and 8.5 [kVA] respectively. The disinfection efficacy which is carried out in a BWTS equipped with the UV lamp and magnetic ballast was over 99.99 [%], and this satisfy the IMO regulations.