• 제목/요약/키워드: Ultra Fast MRI

검색결과 7건 처리시간 0.022초

DSP를 이용한 자기공명영상시스템의 경사자계 파형 발생기 (Gradient Waveform Synthesizer in Magnetic Resonance Imaging System using Digital Signal Processors)

  • 고광혁;권의석;김치영;김휴정;김상묵;안창범
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권1호
    • /
    • pp.48-53
    • /
    • 2000
  • In this paper, we develop a TMS320C31 (60MHz) digital signal processor (DSP) board to synthesize gradient waveforms for Spiral Scan Imaging (SSI), which is one of the ultra fast magnetic resonance imaging (MRI) methods widely used. In SSI, accurate gradient waveforms are very essential to high quality magnetic resonance images. For this purpose, sampling rate for synthesizing the gradient waveforms is set twice as high as the data sampling rate. With the developed DSP boards accurate gradient waveforms are obtained. Ultra fast spiral scan imaging with the developed with the developed DSP board is currently under development.

  • PDF

DSP를 이용한 자기공명영상의 경사자계 파형 발생기 개발 (Development of MRI gradient waveform generator using DSP)

  • 고광혁;권의석;송영철;김휴정;김치영;안창범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3147-3149
    • /
    • 1999
  • In this paper, we develop a TMS320C31- 60 DSP board to generate spiral gradient waveforms for Spiral imaging, one of the ultra fast MRI methods. In Spiral imaging, accurate gradient waveforms are very important to acquire high quality image. For this purpose, sampling rate for generating the gradient waveforms is set twice as high as the data sampling rate. With the developed DSP board accurate gradient waveforms are obtained. Ultra fast MR image with the developed DSP board is currently under development.

  • PDF

3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구 (A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study)

  • 이석준;유승만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.253-259
    • /
    • 2015
  • 본 연구에서는 가돌리늄 조영제를 다양한 몰농도로 희석하여 T1 효과를 나타내는 펄스 시퀀스 중 고속스핀에코와 에코타임이 극도로 짧은 ultra short time echo에서 최대 신호 강도 분포를 나타내는 조영제 희석 몰농도를 3.0T에서 각각 알아보고자 하였다. T1 조영제인 gadoxetic acid 와 완충용액으로는 증류수, 2% agarose gel을 이용하여 다양한 몰농도로 조영제 팬텀을 제작하였다. 팬텀 제작의 정확성을 측정하기 위해 T1 이완시간 측정의 표준방식인 2D inversion recovery spine-echo 펄스시퀀스를 이용하였으며 팬텀의 중간 부의 한 개의 관상면 영상을 획득하여 T1 이완 시간을 계산하였다. 스핀에코에서는 1-2 mmol/L 조영제 몰농도에서 가장 높은 신호를 나타냈으며, ultra short time echo에서는 7 mmol/L에서 가장 큰 신호를 나타냈다. ultra short time echo 펄스 시퀀스를 이용한 조영증강 효과를 보기 위해서는 고속스핀에코 기법 보다 2-3배의 조영제 농도가 목적 장기에 유지하여야 하며 이와 관련된 조영제량 및 투여 방법의 연구가 이루어져야 한다.

DC offset을 보정한 나선 주사 초고속 자기공명영상의 재구성 알고리즘 (Improved Reconstruction Algorithm for Spiral Scan Fast MR Imaging with DC offset Correction)

  • 안창범;김휴정
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.243-250
    • /
    • 1998
  • 초고속 자기공명 영상 기법의 일종인 나선 주사 영상의 재구성을 위하여 k-공간에서 극좌표와 직각 좌표계를 기초로한 재구성방법들을 분석하였다. 나선 주사 영상의 재구성은 나선 궤적상에서 측정된 데이터를 극좌표나 직각 좌표계로 변환시키기 위하여 보간 기술들이 사용된다. 나선주사 영상의 다양한 재구성 알고리즘들을 시험하여 보았고, 재구성된 영상의 질을 비교하였다. 본 연구진이 제안한 투영 영역에서 dc-offset보정을 한 향상된 재구성 알고리즘이 시뮬레이션을 통하여 가장 우수한 것으로 나타났다. 또한, 기존의 재구성 방법들에서 나타났던 영상 artifact도 제안된 방법에서는 완전히 사라짐을 확인할 수 있었다.

  • PDF

Interleaved 나선 주사 영상 (Interleaved Spiral Scan Imaging)

  • 안창범;김휴정;신진교
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.98-99
    • /
    • 1998
  • In this paper, an interleaved spiral scan imaging is investigated for an ultra fast MR imaging. The interleaved spiral technique has relative advantage over single shot spiral imaging with improved resolution and less inhomogeneity-related artifact. An improved reconstruction algorithm is devised with DC-offset correction. Some preliminary experimental results are shown at 1.0 Tesla and 3.0 Tesla whole body MRI system.

  • PDF

Representation Techniques for 4-Dimensional MR Images

  • Homma, Kazuhiro;Takenaka, Kenji;Nakai, Yoshihiko;Hirose, Takeshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.429-431
    • /
    • 2002
  • Metabolic analysis of biological tissues, the interventional radiology in MRT (Magnetic Resonance Treatment) and for clinical diagnoses, representation of 4-Dimensional (4D) structural information (x,y,z,t) of biological tissues is required. This paper discusses image representation techniques for those 4D MR Images. We have proposed an image reconstruction method for ultra-fast 3D MRI. It is based on image interpolation and prediction of un-acquired pictorial data in both of the real and the k-space (the acquisition domain in MRI). A 4D MR image is reconstructed from only two 3D MR images and acquired a few echo signals that are optimized by prediction of the tissue motion. This prediction can be done by the phase of acquired echo signal is proportioned to the tissue motion. On the other hand, reconstructed 4D MR images are represented as a 3D-movie by using computer graphics techniques. Rendered tissue surfaces and/or ROIs are displayed on a CRT monitor. It is represented in an arbitrary plane and/or rendered surface with their motion. As examples of the proposed representation techniques, the finger and the lung motion of healthy volunteers are demonstrated.

  • PDF

3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming (Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System)

  • 김판기;임종우;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.95-102
    • /
    • 2007
  • 목적: 3.0 Tesla와 같은 고 자장에서 고해상도의 나선주사영상을 얻기 위해서는 주자장을 균일하게 만들어야 한다. 특히, 나선주사영상인 경우 스핀-에코펄스 시퀀스(SE)나 경사자계 에코 펄스 시퀀스(GE)에 비하여 측정 시간이 길기 때문에 주자장이 균일하지 못하다면, off-resonance 현상으로 영상의 blur가 심해진다. 본 연구에서는 빠른 시간 안에 주자장을 균일하게 할 수 있는 고차(Higher-order) shimming방법을 모색했다. 대상 및 방법: 3 Tesla 자기 공명 영상시스템에서 고해상도의 나선주사영상을 얻기에 적합할 정도의 균일한 주자장을 빠른 시간 안에 만들기 위해, 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구할 수 있는 펄스 시퀀스를 제안하였고, 불균일도 map으로부터 spherical harmonics 분석를 통해 shim 코일에 적절한 전류를 인가하여 주자장을 균일하게 만들었다. 결과: 3 Tesla 자기 공명 영상 시스템에서 주자장의 불균일도는 주자장의 크기에 비례하게 된다. 제안한 펄스 시퀀스로 얻은 영상을 이용하여 불균일도 Map을 만들 수 있었고, 이를 spherical harmonics 분석을 하여 2-3회의 고차 shimming으로 불균일한 자장을 균일하게 만들 수 있었다. 제안된 고차 shimming 방법은 전체 영상 영역 뿐만 아니라 선택한 영역에 대해서만 적용도 가능하기 때문에 국부 영역에 대한 고차 shimming이 가능하다. 고차 shimming이 적용되어 주자장이 균일하게 개선된 상태에서 고해상도의 나선주사영상을 얻을 수 있었다. 결론: 3 Tesla 고자장 자기 공명 영상 시스템에서 주자장의 불균일도를 개선하기 위한 펄스 시퀀스와 알고리즘을 통해 주자장의 불균일도를 빠른 시간 안에 개선할 수 있었다. 주자장의 불균일도를 효과적으로 개선함으로써, 고해상도의 나선주사 영상을 얻을 수 있었다.

  • PDF