• 제목/요약/키워드: Ultimate strength analysis

검색결과 722건 처리시간 0.03초

중심축력하의 콘크리트 충전 각형강관 기둥의 비선형 해석 (Nonlinear Analysis of Concrete Filled Steel Tubular Column under Concentric Axial Load)

  • 김선웅;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.613-616
    • /
    • 2003
  • Steel-concrete composite columns are used extensively in modern buildings. Extensive research on composite columns in which structural steel are in concrete have been carried out. In-filled composite columns, however have received limited attention compared to encased columns. In this paper, interrelationship of parameters is examined into analyzing and comparing with data through ABAQUS program and experiment on concrete filled tubular column under axial load and propriety of model is checked out by FEM analysis. The main variations of this paper are width-thickness ratio of the section(B/t =33.3, 38.9, 44.4), concrete strength($f_{ck}$=240, 360kgf/$\textrm{cm}^2$), and width-length ratio($L_o$/B=8.0, 10.0, 12.0, 15.0, 20.0). The ultimate value obtained through analysis is compared with test value and calculated by design code of other countries and previous studies.

  • PDF

Numerical modelling and codification of imperfections for cold-formed steel members analysis

  • Dubina, Dan;Ungureanu, Viorel;Rondal, Jacques
    • Steel and Composite Structures
    • /
    • 제5권6호
    • /
    • pp.515-533
    • /
    • 2005
  • Buckling and post-buckling of cold-formed steel members are rather difficult to predict due to material and geometrical non-linearity. However, numerical techniques have reached a level of maturity such that many are now successfully undertaking ultimate strength analysis of cold-formed steel members. In numerical non-linear analysis, both geometrical and material imperfections, have to be estimated and properly used. They must be codified in terms of shape and magnitude. The presented paper represents a state-of-art report, including relevant results obtained by the authors and collected from literature, on that problem.

Parametric analysis and torsion design charts for axially restrained RC beams

  • Bernardo, Luis F.A.;Taborda, Catia S.B.;Gama, Jorge M.R.
    • Structural Engineering and Mechanics
    • /
    • 제55권1호
    • /
    • pp.1-27
    • /
    • 2015
  • This article presents a theoretical parametric analysis on the ultimate torsional behaviour of axially restrained reinforced concrete (RC) beams. This analysis is performed by using a computing procedure based on a modification of the Variable Angle Truss Model. This computing procedure was previously developed to account for the influence of the longitudinal compressive stress state due to the axial restraint conditions provided by the connections of the beams to other structural members. The presented parametric study aims to check the influence of some important variable studies, namely: torsional reinforcement ratio, compressive concrete strength and axial restraint level. From the results of this parametric study, nonlinear regression analyses are performed and some design charts are proposed. Such charts allow to correct the resistance torque of RC beams (rectangular sections with small height to width ratios) to account for the favorable influence of the axial restraint.

Mechanical behavior of outer square inner circular concrete-filled dual steel tubular stub columns

  • Ding, Fa-xing;Wang, Wenjun;Liu, Xue-mei;Wang, Liping;Sun, Yi
    • Steel and Composite Structures
    • /
    • 제38권3호
    • /
    • pp.305-317
    • /
    • 2021
  • The mechanical behavior of the outer square inner circular concrete-filled dual steel tubular (SCCFT) stub columns under axial compression is investigated by means of experimental research, numerical analysis and theoretical investigation. Parameters such as diameter ratio, concrete strength and steel ratio were discussed to identify their influence on the mechanical properties of SCCFT short columns on the basis of the experimental investigation of seven SCCFT short columns. By establishing a finite element model, nonlinear analysis was performed to discuss the longitudinal and transverse stress of the dual steel tubes. The longitudinal stress characteristics of the core and sandwich concrete were also analyzed. Furthermore, the failure sequence was illustrated and the reasonable cross-section composition of SCCFT stub column was proposed. A formula to predict the axial load capacity of SCCFT stub column was advanced and verified by the results from experiment and the finite element.

치과용 복합레진으로 수리된 CAD-CAM hybrid 수복물의 전단결합강도 (Shear bond strength of dental CAD-CAM hybrid restorative materials repaired with composite resin)

  • 문윤희;이종혁;이명구
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.193-202
    • /
    • 2016
  • 목적: 본 연구에서는 치과용 CAD-CAM (computer aided design-computer aided manufacturing) hybrid 수복재료인 LAVA Ultimate와 VITA ENAMIC을 광중합 복합레진을 사용하여 수리할 때 표면처리방법(grinding, air abrasion with aluminum oxide, HF acid)과 접착재료(Adper Single Bond 2, Single Bond Universal)의 종류가 두 재료 사이의 전단결합강도에 어떠한 영향을 미치는지 알아보고자 하였다. 재료 및 방법: LAVA Ultimate와 VITA ENAMIC 시편을 30일간 $37^{\circ}C$의 인공타액(Xerova solution)에 보관하여 시효처리를 실시한 후 각각 SiC paper grinding한 것, grinding 후 air abrasion처리를 추가한 것, grinding 후 HF 처리한 것으로 분류하고 각각 no bonding, Adper Single Bond 2, 또는, Single Bond Universal 도포로 세분하여 9개의 group, 총 18개의 subgroup으로 나누어 실험을 실시하였다(N=10). HF 처리group에서는 도재시편을 대조군으로 추가하였다(N=10). 표면 처리 후 광중합 복합레진(Filtek Z250)을 각각의 시편에 부착하고 이를 1주일간 실온의 물에 침적시켰고 이후 전단결합강도를 측정하고 파절양상 및 표면처리 효과를 SEM으로 확인하였다. One-way ANOVA를 이용하여 group 간의 유의성을 분석하였고 사후 분석으로 Scheffe test를 실시하였다(${\alpha}=.05$). 결과: 실험 결과 접착재료 처리를 한 group들이 접착재료 처리를 하지 않은 group에 비해 모든 표면처리에서 더 높은 전단결합력을 나타내었으며, 표면처리만 시행한 group에서는 aluminum oxide air abrasion이 전단결합력의 증가에 약간의 영향을 미치는 것으로 나타났으나 통계적 유의성은 보이지 않았다. 결론: LAVA Ultimate와 VITA ENAMIC의 두 재료를 광중합 복합레진을 이용하여 수리를 실시할 경우 각각의 재료에 적합한 표면처리방법과 접착재료의 선택에 대한 연구가 더 필요할 것으로 사료된다. 특히 LAVA Ultimate의 경우 접착재료의 사용은 추천된다고 사료되었다.

현장타설 습식접합부가 있는 T형 PC 벽체의 내진성능 (Seismic Performance of T-Shaped PC Walls with Wet Cast Joint)

  • 임우영;홍성걸
    • 콘크리트학회논문집
    • /
    • 제26권3호
    • /
    • pp.255-266
    • /
    • 2014
  • 이 논문은 새로운 수직 접합부와 현장타설 습식 접합부를 가진 T형 프리캐스트 벽체의 내진 성능에 관한 연구이다. 반복하중을 받는 T형 PC 벽체의 하중-변위 관계, 강도, 연성도, 파괴 모드, 그리고 변형 능력에 대해 알아보았다. 실험체 주요 변수는 전단력 전달을 위한 대각 철근의 유무이다. 벽체의 양단에 위치한 길이방향 주철근이 먼저 항복을 하였고 최종 변형은 C형 접합부의 파괴에 의해 결정되었다. 그리고 전단력 전달을 위한 대각 철근은 균열 제어에 효과적인 것으로 나타났다. 단면 해석을 통해 구한 강도와 변형은 실험값과 대체로 일치하였다.

Experimental study on seismic performance of steel reinforced concrete T-shaped columns

  • Liu, Zuqiang;Zhou, Chaofeng;Xue, Jianyang;Leon, Roberto T.
    • Steel and Composite Structures
    • /
    • 제36권3호
    • /
    • pp.339-353
    • /
    • 2020
  • This study investigates the seismic performance of steel reinforced concrete (SRC) T-shaped columns under low cyclic loading tests. Based on test results of ten half-scale column specimens, failure patterns, hysteretic behavior, skeleton curves, ultimate strength, ductility, stiffness degradation and energy dissipation capacity were analyzed. The main variables included loading angles, axial compression ratios and steel ratios. The test results show that the average values of the ductility factor and the equivalent viscous damping coefficient with respect to the failure of the columns were 5.23 and 0.373, respectively, reflecting good seismic performance. The ductility decreased and the initial stiffness increased as the axial compression ratio of the columns increased. The strength increased with increasing steel ratio, as expected. The columns displaced along the web had higher strength and initial stiffness, while the columns displaced along the flange had better ductility and energy dissipation capacity. Based on the test and analysis results, a formula is proposed to calculate the effective stiffness of SRC T-shaped columns.

Behavior and design of perforated steel storage rack columns under axial compression

  • El Kadi, Bassel;Kiymaz, G.
    • Steel and Composite Structures
    • /
    • 제18권5호
    • /
    • pp.1259-1277
    • /
    • 2015
  • The present study is focused on the behavior and design of perforated steel storage rack columns under axial compression. These columns may exhibit different types of behavior and levels of strength owing to their peculiar features including their complex cross-section forms and perforations along the member. In the present codes of practice, the design of these columns is carried out using analytical formulas which are supported by experimental tests described in the relevant code document. Recently proposed analytical approaches are used to estimate the load carrying capacity of axially compressed steel storage rack columns. Experimental and numerical studies were carried out to verify the proposed approaches. The experimental study includes compression tests done on members of different lengths, but of the same cross-section. A comparison between the analytical and the experimental results is presented to identify the accuracy of the recently proposed analytical approaches. The proposed approach includes modifications in the Direct Strength Method to include the effects of perforations (the so-called reduced thickness approach). CUFSM and CUTWP software programs are used to calculate the elastic buckling parameters of the studied members. Results from experimental and analytical studies compared very well. This indicates the validity of the recently proposed approaches for predicting the ultimate strength of steel storage rack columns.

Behavior of FRP-reinforced steel plate shear walls with various reinforcement designs

  • Seddighi, Mehdi;Barkhordari, Mohammad A.;Hosseinzadeh, S.A.A.
    • Steel and Composite Structures
    • /
    • 제33권5호
    • /
    • pp.729-746
    • /
    • 2019
  • The nonlinear behavior of single- and multi-story steel plate shear walls (SPSWs) strengthened with three different patterns of fiber reinforced polymer (FRP) laminates (including single-strip, multi-strip and fully FRP-strengthened models) is studied using the finite element analysis. In the research, the effects of orientation, width, thickness and type (glass or carbon) of FRP sheets as well as the system aspect ratio and height are investigated. Results show that, despite an increase in the system strength using FRP sheets, ductility of reinforced SPSWs is decreased due to the delay in the initiation of yielding in the infill wall, while their initial stiffness does not change significantly. The content/type/reinforcement pattern of FRPs does affect the nonlinear behavior characteristics and also the mode and pattern of failure. In the case of multi-strip and fully FRP-strengthened models, the use of FPR sheets almost along the direction of the infill wall tension fields can maximize the effectiveness of reinforcement. In the case of single-strip pattern, the effectiveness of reinforcement is decreased for larger aspect ratios. Moreover, a relatively simplified and approximate theoretical procedure for estimating the strength of SPSWs reinforced with different patterns of FRP laminates is presented and compared with the analytical results.

Axial compressed UHPC plate-concrete filled steel tubular composite short columns, Part I: Bearing capacity

  • Jiangang Wei;Zhitao Xie;Wei Zhang;Yan Yang;Xia Luo;Baochun Chen
    • Steel and Composite Structures
    • /
    • 제47권3호
    • /
    • pp.405-421
    • /
    • 2023
  • An experimental study on six axially-loaded composite short columns with different thicknesses of steel tube and that of the concrete plate was carried out. Compared to the mechanical behavior of component specimens under axially compressed, the failure modes, compression deformation, and strain process were obtained. The two main parameters that have a significant enhancement to cross-sectional strength were also analyzed. The failure of an axially loaded UHPC-CFST short column is due to the crushing of the UHPC plate, while the CFST member does reach its maximum resistance. A reduction coefficient K'c, related to the confinement coefficient, is introduced to account for the contribution of CFST members to the ultimate load-carrying capacity of the UHPC-CFST composite short columns. Based on the regression analysis of the relationship between the confinement index ξ and the value of fcc/fc, a unified formula for estimating the axial compressive strength of CFST short columns was proposed, combined with the experimental results in this research, and an equation for reliably predicting the strength of UHPC-CFST composite short columns under axial compression were also proposed.