• 제목/요약/키워드: Ultasonic

검색결과 10건 처리시간 0.035초

초음파 분량법에 의한 레진 내부 결합의 크기 측정에 관한 연구 (Sizing of lnner Flaw in Resin by using Ultrasonic spectroscopy)

  • Han, E.K.;Kim, Y.J.;Park, I.G.
    • 한국정밀공학회지
    • /
    • 제10권3호
    • /
    • pp.182-190
    • /
    • 1993
  • In manufacturing process of semiconductor package, the thermal stress owing to high temperature in moulding and the bubbles generated in chip bonding process become main causes to produce void. On this study we evaluated quantitatively void size by use of ultrasonic spectroscopy method which analyze the reflective pulses with broad band frequency in frequency domain, and after destructive testing we verified effectiv- eness of sizing void by use of ultasonic spectroscopy.

  • PDF

기구조작후 치근표면의 조도에 관한 연구; 주사전자현미경적 in vivo 및 in vitro 연구 (Root surface roughness following mechanical instrumentation in vivo and in vitro SEM study)

  • 이영규
    • Journal of Periodontal and Implant Science
    • /
    • 제28권4호
    • /
    • pp.809-822
    • /
    • 1998
  • Adequate root preparation in the treatment of periodontal disease often involves mechanical instrumentation to remove plaque, calculus perhaps contaminated cementum. Although meticulous scaling and root planing may remove some cementum, the use of aggressive root planing to remove cementum does not appear warranted. So ultrasonic device and rotary instrument appear to be replacing hand instrument. But it is not clear those instruments make smooth root surface as hand instrument. The roghness of the root surface were evaluate with SEM following instrumentation with Gracey curette, Perio Clean and piezo ultrasonic device(Setlec) with various tip. 20 extracted teeth were used in vitro experiment, and 9 teeth of a patient destined for extraction for periodontal reasons were utilized in vivo experiment. It was demonstrated that hand curette created the smoothest surface, while diamond tip tended to roughen the root surface. But the hand curette, Perio Clean, and piezo ultasonic device with scaler tip tend to remove cementum completely. Piezo ultrasonic device with curette-like tip made the desirable smooth surface with partial removal of cementum.

  • PDF

분산제어명령 기반의 비용함수 최소화를 이용한 장애물회피와 주행기법 (Obstacle Avoidance and Planning using Optimization of Cost Fuction based Distributed Control Command)

  • 배동석;진태석
    • 한국산업융합학회 논문집
    • /
    • 제21권3호
    • /
    • pp.125-131
    • /
    • 2018
  • In this paper, we propose a homogeneous multisensor-based navigation algorithm for a mobile robot, which is intelligently searching the goal location in unknown dynamic environments with moving obstacles using multi-ultrasonic sensor. Instead of using "sensor fusion" method which generates the trajectory of a robot based upon the environment model and sensory data, "command fusion" method by fuzzy inference is used to govern the robot motions. The major factors for robot navigation are represented as a cost function. Using the data of the robot states and the environment, the weight value of each factor using fuzzy inference is determined for an optimal trajectory in dynamic environments. For the evaluation of the proposed algorithm, we performed simulations in PC as well as real experiments with mobile robot, AmigoBot. The results show that the proposed algorithm is apt to identify obstacles in unknown environments to guide the robot to the goal location safely.

초음파 족욕를 이용한 수치료에 대한 임상적 연구 (The Clinical Study of Hydrotherapy Based Ultrasonic Spa)

  • 최종민;김희택;류주현;이인수
    • 한방안이비인후피부과학회지
    • /
    • 제18권1호
    • /
    • pp.172-182
    • /
    • 2005
  • Objective : The purpose of this study was to know the clinical effect of Hydrotherapy based Ultasonic spa on Atopic Dermatitis and Allergic Rhinitis. Methods : Allery Test(MAST CLA Allergy system, inhalant panel), DITI, Bio Chemistry, Hematology were investigated in 20 patients(Atopic Dermatitis 10, Allergic Rhinitis 10) who visited Department of Ophthalmology & Otolaryngology & Dermatology, Semyung Oriental medicine hospital from November 2004 to January 2005. Results : 1. In atopic dermatitis patients, there was good in 7 cases(70%), excellent in 3 cases(30%). 2. In allergic rhinitis patients there was improved in 5 eases(50%), good in 2 cases(20%), unimproved in 3cases(30%). 3. In conclusion, there was good(doctor and patients ail) in 6(60%), unimproved in 3(30%) Conclusion : Hydrotherapy based Utasonic spa showed useful effect on Atopic Dermatitis and Allergic Rhinitis.

  • PDF

저항용접에서의 용접성 평가에 관한 연구 (A Study on the Evaluation of Weldability in Spot Welding)

  • 홍민성;김종민
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.301-306
    • /
    • 2003
  • Spot welding is frequently used for industrial purpose, such as automobile and aerospace industries and household appliances due to its high performance. In these day, robotization and systemization of welding process made it possible to produce more precise or smaller electric parts. And when it comes to welding of steel sheet, the size of nugget must be getting smaller. Therefore, welding conditions are limited to avoid defects, such as deformation, damage, weakening of joining area. In this research, the measurement of the nugget size by the nondestructive inspection has been conducted. As a result, the right estimation of the nugget size and void defects, the detection of corona bond near joining area, the selection of the optimum ultrasonic mode, and set up for ultrasonic inspection are studied. From the trustworthy solutions of nugget size estimated by results of measurement, the optimum inspection conditions depending upon the width of welding parts are determined as well.

  • PDF

미세금형제작을 위한 가공기술개발 (Development of Machining Technology for Micro Dies and Molds)

  • 이응숙;신영재;강재훈;제태진;이재경;이현용;이상조;최헌종;주종남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.1047-1050
    • /
    • 2000
  • As the progress of new industrial products or parts technology, the precise and fine machining technologies are needed more and more. Micro fabrication technology of these products are usally consisted of mechanical machining or MEMS technology. Direct machining by mechanical method is not applicable to mass production. MEMS technology also has several problems such as low mechanical strength, bad surface roughness and difficulty of 3 dimensional machining. In this study, we introduce several micro fabrication technology to make micro molds and dies and our project to develop these machining technology.

  • PDF

초음파를 이용한 미세저항용접에서의 용접성 평가에 관한 연구 (A Study on the Evaluation of Weldability Using Ultrasonic in Thin Spot Welding)

  • 홍민성;김종민
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.49-53
    • /
    • 2004
  • Thin spot welding is frequently used for industrial purpose, such as automobile and aerospace industries and household appliances due to its high performance. In these days, the systemization of welding process made it possible to produce more precise or smaller electric parts. And when it comes to welding of steel sheets, the size of nugget must be getting smaller. Therefore, welding conditions are limited to avoid defects, such as deformation, damage and weakening of joining area. In this research, thin spot welding establishes the welding conditions, and then the measurement of the nugget size by the nondestructive inspection has been conducted. As a result, the right estimation of the nugget size, the detection of corona bond near joining area, the selection of the optimum ultrasonic mode, and setup for ultrasonic inspection are studied. From the trustworthy solutions of the nugget size estimated by results of measurement, the optimum inspection conditions depending upon the width of welding parts are determined as well.

  • PDF

폭약살포 높이에 따른 Al/steel 폭발 접합계면의 형상 및 조직 변화에 관한 연구 (A Study on the Shape and Microstructural Change of Explosion-Welding Al/Steel Interface with Explosive Thickness)

  • 김희진;강봉용
    • Journal of Welding and Joining
    • /
    • 제14권4호
    • /
    • pp.62-70
    • /
    • 1996
  • Al or Al-alloy have been known to be able to be claded on various materials by using explosive welding process, however, the intermetallic layer frequently formed along the interface have made this process very complicated. In this study, it was focussed to select the process variables, which can get rid of interfacial layer in the Al-claded steel plate. As a result, it was demonstrated that there was a certain range of explosive thickness which did not form the intermetallic phase as well as the non-bonded area. On the other hand, ultasonic tests performed for identifying the presence of interfacial layer nondestructively showed that it could be applied for the intended purpose but its result was weakly related with the microstructural quality of interface.

  • PDF

공기 중 광대역 초음파 방사용 압전 박막 기반 초소형 초음파 트랜스듀서의 설계 (Design of piezoelectric micro-machined ultrasonic transducer for wideband ultasonic radiation in air)

  • 안홍민;진재혁;문원규
    • 한국음향학회지
    • /
    • 제39권2호
    • /
    • pp.87-97
    • /
    • 2020
  • 본 논문에서는 공기 중 광대역 초음파 방사용 압전 박막 기반 초소형 초음파 트랜스듀서(piezoelectric Micro-machined Ultrasonic Transducer, pMUT)의 설계 연구가 진행되었다. 하나의 트랜스듀서로 광대역을 달성하는 방법 중 하나는 다공진 시스템으로 설계하는 것이다. 새로운 pMUT은 박막 구조의 앞면과 뒷면에 적절한 음향 구조를 추가하여 다공진 시스템을 구현하도록 설계되었다. 박막 앞쪽은 도파관 구조로 모델링된 방사 파트로, 박막 뒷쪽은 음향 공동으로 모델링된 패키징 파트로 이루어져있다. 박막 파트, 방사 파트, 패키징 파트로 구성된 새로운 pMUT은 집중 변수 모델로 설계되었으며, 최종적으로 유한요소해석으로 검증되었다. 최종 설계된 pMUT은 102 kHz ~ 132 kHz (-3 dB)의 주파수 대역을 달성하였다.

수중코오너리프렉터의 초음파반사특성에 관한 연구 (Ultasonic Reflection Characteristics of the Underwater Corner Reflector)

  • 이대재;신형일
    • 수산해양기술연구
    • /
    • 제19권1호
    • /
    • pp.25-32
    • /
    • 1983
  • 레이다에서 전파반사표식으로 사용하고 있는 코오너리프렉터를 수중 초음파반사표지로 응용하기 위하여, 코오너리프렉터의 수중초음파반사특성을 이론적으로 고찰하고, 28,50,75KHz의 주파수에 대하여 주파수가 높을수록 높았고, 반사지향성은 직경이 증가함에 따라 예리하였다. 2. 직경이 150mm이고, 코오너각이 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$, 90$^{\circ}$인 코오너리프렉터의 최대반사강도는 각각 -25.0dB, -17.2dB, -15.2dB, -13.4dB, -11.0dB로서, 코오너각이 증가함에 따라 점차 증가하는 경향을 나타내었으나, 그 주엽 수는 코오너각이 증가함에 따라 점차 감소하였다. 3. 직경이 80mm이고, 코오너각이 90$^{\circ}$인 코오너리프렉터를 2,3,4,5,6,7개씩 음속축을 중심으로 간격없이 평면배열한 경우에 있어서, 반사강도는 각각 -18.2dB, -16.5dB, -15.4dB, -14.3dB, -13.4dB, -12.9dB로서, 이론치와 거의 일치하였으며, 코오너리프렉터수의 평방근에 비례하였다. 4. 직경이 80mm인 코오너리프렉터의 방향각(0,$\theta$sub(a))이 0$^{\circ}$, 2.5$^{\circ}$, 5$^{\circ}$, 7.5$^{\circ}$, $10^{\circ}$, 12.5$^{\circ}$인 경우, 반사강도는 각각 -21.2dB, -21.9dB, -23.4dB, -26.0dB, -30.0dB, -36.8dB로서, 방향성이 증가함에 따라 반사강도는 급격히 감소하는 경향을 나타내었다.

  • PDF