• Title/Summary/Keyword: Ultasonic

Search Result 10, Processing Time 0.025 seconds

Sizing of lnner Flaw in Resin by using Ultrasonic spectroscopy (초음파 분량법에 의한 레진 내부 결합의 크기 측정에 관한 연구)

  • Han, E.K.;Kim, Y.J.;Park, I.G.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.3
    • /
    • pp.182-190
    • /
    • 1993
  • In manufacturing process of semiconductor package, the thermal stress owing to high temperature in moulding and the bubbles generated in chip bonding process become main causes to produce void. On this study we evaluated quantitatively void size by use of ultrasonic spectroscopy method which analyze the reflective pulses with broad band frequency in frequency domain, and after destructive testing we verified effectiv- eness of sizing void by use of ultasonic spectroscopy.

  • PDF

Root surface roughness following mechanical instrumentation in vivo and in vitro SEM study (기구조작후 치근표면의 조도에 관한 연구; 주사전자현미경적 in vivo 및 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.809-822
    • /
    • 1998
  • Adequate root preparation in the treatment of periodontal disease often involves mechanical instrumentation to remove plaque, calculus perhaps contaminated cementum. Although meticulous scaling and root planing may remove some cementum, the use of aggressive root planing to remove cementum does not appear warranted. So ultrasonic device and rotary instrument appear to be replacing hand instrument. But it is not clear those instruments make smooth root surface as hand instrument. The roghness of the root surface were evaluate with SEM following instrumentation with Gracey curette, Perio Clean and piezo ultrasonic device(Setlec) with various tip. 20 extracted teeth were used in vitro experiment, and 9 teeth of a patient destined for extraction for periodontal reasons were utilized in vivo experiment. It was demonstrated that hand curette created the smoothest surface, while diamond tip tended to roughen the root surface. But the hand curette, Perio Clean, and piezo ultasonic device with scaler tip tend to remove cementum completely. Piezo ultrasonic device with curette-like tip made the desirable smooth surface with partial removal of cementum.

  • PDF

Obstacle Avoidance and Planning using Optimization of Cost Fuction based Distributed Control Command (분산제어명령 기반의 비용함수 최소화를 이용한 장애물회피와 주행기법)

  • Bae, Dongseog;Jin, Taeseok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.3
    • /
    • pp.125-131
    • /
    • 2018
  • In this paper, we propose a homogeneous multisensor-based navigation algorithm for a mobile robot, which is intelligently searching the goal location in unknown dynamic environments with moving obstacles using multi-ultrasonic sensor. Instead of using "sensor fusion" method which generates the trajectory of a robot based upon the environment model and sensory data, "command fusion" method by fuzzy inference is used to govern the robot motions. The major factors for robot navigation are represented as a cost function. Using the data of the robot states and the environment, the weight value of each factor using fuzzy inference is determined for an optimal trajectory in dynamic environments. For the evaluation of the proposed algorithm, we performed simulations in PC as well as real experiments with mobile robot, AmigoBot. The results show that the proposed algorithm is apt to identify obstacles in unknown environments to guide the robot to the goal location safely.

The Clinical Study of Hydrotherapy Based Ultrasonic Spa (초음파 족욕를 이용한 수치료에 대한 임상적 연구)

  • Choi, Jong-Min;Kim, Hee-Taek;Ryu, Ju-Hyun;Lee, In-Su
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.18 no.1
    • /
    • pp.172-182
    • /
    • 2005
  • Objective : The purpose of this study was to know the clinical effect of Hydrotherapy based Ultasonic spa on Atopic Dermatitis and Allergic Rhinitis. Methods : Allery Test(MAST CLA Allergy system, inhalant panel), DITI, Bio Chemistry, Hematology were investigated in 20 patients(Atopic Dermatitis 10, Allergic Rhinitis 10) who visited Department of Ophthalmology & Otolaryngology & Dermatology, Semyung Oriental medicine hospital from November 2004 to January 2005. Results : 1. In atopic dermatitis patients, there was good in 7 cases(70%), excellent in 3 cases(30%). 2. In allergic rhinitis patients there was improved in 5 eases(50%), good in 2 cases(20%), unimproved in 3cases(30%). 3. In conclusion, there was good(doctor and patients ail) in 6(60%), unimproved in 3(30%) Conclusion : Hydrotherapy based Utasonic spa showed useful effect on Atopic Dermatitis and Allergic Rhinitis.

  • PDF

A Study on the Evaluation of Weldability in Spot Welding (저항용접에서의 용접성 평가에 관한 연구)

  • 홍민성;김종민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.301-306
    • /
    • 2003
  • Spot welding is frequently used for industrial purpose, such as automobile and aerospace industries and household appliances due to its high performance. In these day, robotization and systemization of welding process made it possible to produce more precise or smaller electric parts. And when it comes to welding of steel sheet, the size of nugget must be getting smaller. Therefore, welding conditions are limited to avoid defects, such as deformation, damage, weakening of joining area. In this research, the measurement of the nugget size by the nondestructive inspection has been conducted. As a result, the right estimation of the nugget size and void defects, the detection of corona bond near joining area, the selection of the optimum ultrasonic mode, and set up for ultrasonic inspection are studied. From the trustworthy solutions of nugget size estimated by results of measurement, the optimum inspection conditions depending upon the width of welding parts are determined as well.

  • PDF

Development of Machining Technology for Micro Dies and Molds (미세금형제작을 위한 가공기술개발)

  • 이응숙;신영재;강재훈;제태진;이재경;이현용;이상조;최헌종;주종남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.1047-1050
    • /
    • 2000
  • As the progress of new industrial products or parts technology, the precise and fine machining technologies are needed more and more. Micro fabrication technology of these products are usally consisted of mechanical machining or MEMS technology. Direct machining by mechanical method is not applicable to mass production. MEMS technology also has several problems such as low mechanical strength, bad surface roughness and difficulty of 3 dimensional machining. In this study, we introduce several micro fabrication technology to make micro molds and dies and our project to develop these machining technology.

  • PDF

A Study on the Evaluation of Weldability Using Ultrasonic in Thin Spot Welding (초음파를 이용한 미세저항용접에서의 용접성 평가에 관한 연구)

  • 홍민성;김종민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.49-53
    • /
    • 2004
  • Thin spot welding is frequently used for industrial purpose, such as automobile and aerospace industries and household appliances due to its high performance. In these days, the systemization of welding process made it possible to produce more precise or smaller electric parts. And when it comes to welding of steel sheets, the size of nugget must be getting smaller. Therefore, welding conditions are limited to avoid defects, such as deformation, damage and weakening of joining area. In this research, thin spot welding establishes the welding conditions, and then the measurement of the nugget size by the nondestructive inspection has been conducted. As a result, the right estimation of the nugget size, the detection of corona bond near joining area, the selection of the optimum ultrasonic mode, and setup for ultrasonic inspection are studied. From the trustworthy solutions of the nugget size estimated by results of measurement, the optimum inspection conditions depending upon the width of welding parts are determined as well.

  • PDF

A Study on the Shape and Microstructural Change of Explosion-Welding Al/Steel Interface with Explosive Thickness (폭약살포 높이에 따른 Al/steel 폭발 접합계면의 형상 및 조직 변화에 관한 연구)

  • 김희진;강봉용
    • Journal of Welding and Joining
    • /
    • v.14 no.4
    • /
    • pp.62-70
    • /
    • 1996
  • Al or Al-alloy have been known to be able to be claded on various materials by using explosive welding process, however, the intermetallic layer frequently formed along the interface have made this process very complicated. In this study, it was focussed to select the process variables, which can get rid of interfacial layer in the Al-claded steel plate. As a result, it was demonstrated that there was a certain range of explosive thickness which did not form the intermetallic phase as well as the non-bonded area. On the other hand, ultasonic tests performed for identifying the presence of interfacial layer nondestructively showed that it could be applied for the intended purpose but its result was weakly related with the microstructural quality of interface.

  • PDF

Design of piezoelectric micro-machined ultrasonic transducer for wideband ultasonic radiation in air (공기 중 광대역 초음파 방사용 압전 박막 기반 초소형 초음파 트랜스듀서의 설계)

  • Ahn, Hongmin;Jin, JaeHyeok;Moon, Wonkyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.2
    • /
    • pp.87-97
    • /
    • 2020
  • In this paper, the design of piezoelectric Micro-machined Ultrasonic Transducer (pMUT) for wideband ultrasonic radiation in air was investigated. One of the methods to achieve wide frequency bandwidth in single device is modeling the transducer to multi-resonance system. The new pMUT was designed as a multi-resonance system with the addition of a suitable acoustic structure to the front and back of a thin film structure. A new pMUT consisting of thin film parts, radiation parts, and packaging parts is designed with a Lumped Parameter Model (L.P.M). Finally, it was validated as a Finite Element Method (FEM) simulation. The final designed pMUT achieved a frequency band of 102 kHz ~ 132 kHz (-3 dB).

Ultasonic Reflection Characteristics of the Underwater Corner Reflector (수중코오너리프렉터의 초음파반사특성에 관한 연구)

  • Lee, Dae-Jae;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 1983
  • The corner reflector is used to increase the echoing area of radar targets in the air, and it can also be applied to increase the echoing area of the sonar targets under water. As the basic research for this application, the authors investigated the ultrasonic reflection characteristics under water for the corner reflector which was made of aluminum plate. The experiments were made by pulse measuring method with the magnetostrictive ferrite transducers of 28, 50 and 75KHz in the experimental water tank. The results obtained are as follows; 1. The target strength of corner reflectors were increased in proportion to the diameter and were greater at higher frequency of 75KHz than at lower frequency of 28KHz. 2. In the case of 5 corner reflectors of 150mm in diameter which have corner angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$ and 90$^{\circ}$the measured values of the maximum target strength at 75KHz were-25.0 dB, -17.2dB, -15.1dB, -13.4dB and 11.0dB, and then the number of main lobes showing the maximum target strength in the backscattering patterns were 24, 12, 8, 6 and 4, respectively. 3. When 7 corner reflector of 80mm in diameter and 90$^{\circ}$ in the corner angle was located on the minor axis of the horizontal section with directional angles of 0$^{\circ}$, 2.5$^{\circ}$, 5.0$^{\circ}$, 7.5$^{\circ}$, 10$^{\circ}$ and 12.5$^{\circ}$ against the sound beam axis, the measured values of the target strength on each position at 75KHz were -21.2dB, -21.9dB, -26.0dB, -30.5dB and -36.8dB, respectively.

  • PDF