• 제목/요약/키워드: Ulsan-si

검색결과 367건 처리시간 0.029초

C급 플라이애쉬를 사용한 초유동 콘크리트 특성 (The Properties of Supper Flowing Concrete using Class C Fly Ash)

  • 원철;권영호;김동석;박칠림
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.276-282
    • /
    • 1996
  • This study dealt with the properties for fly ash of combined heat power plant and application for concrete industry. For this purpose, fly ash of ulsan combined heat power plant was analyzed for physical and chemical properties and tested the properties of the super flowing concrete. As results of fly ash, contents of SiO2 and Al2O3 in the fly ash of Ulsan were less than those of thermal power plant(Boryung), but contents of CaO were ten times as much as those of Boryung. In order to satisfy the properties of the Super Flowing Concrete using class C fly ash, mixing conditions were determined the optimum water-binder(w/b), volume ratio of fine aggregates(Sr) and coarse aggregates(Gv).

  • PDF

저주파수 진동형 전자기식 마이크로 발전기의 설계 및 해석 (Design and Analyses of Vibration Driven Electromagnetic Energy Harvester with High Power Generation at Low Frequency)

  • 이병철;정귀상
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.102-106
    • /
    • 2011
  • This paper presents a design and analysis of an electromagnetic micro generator which can convert low frequency vibration energy to electrical power. The design aspects of the micro generator comprised planar spring, Cu coil and a permanent magnet(NdFeB). Threetype spring designs and four materials(Parylene, FR-4, Cu and Si) were compared to find resonance frequency. It was found that the resonance frequency will be changed according to the spring shape and material. Mechanical and magnetic parameters had been adjusted to optimize the output power through a comprehensive theoretical study.

The Effects of Simultaneous Pulmonary Rehabilitation during Thoracic Radiotherapy in the Treatment of Malignant Diseases

  • Choi, Myeong Geun;Lee, Hyang Yi;Song, Si Yeol;Kim, Su Ssan;Lee, Seung Hak;Kim, Won;Choi, Chang-Min;Lee, Sei Won
    • Tuberculosis and Respiratory Diseases
    • /
    • 제84권2호
    • /
    • pp.148-158
    • /
    • 2021
  • Background: Radiotherapy is a common treatment option for lung or esophageal cancer, particularly when surgery is not feasible for patients with poor lung function. However, radiotherapy can affect pulmonary function and thereby induce pneumonitis or pneumonia, which can be fatal in patients with respiratory impairment. The purpose of this study is to evaluate if reductions in pulmonary function after radiotherapy can be minimized through simultaneous pulmonary rehabilitation (PR). Methods: In this matched case control study, we retrospectively analyzed patients who had undergone radiotherapy for thoracic malignant disease between January 2018 and June 2019. We analyzed results from pulmonary function tests and 6-minute walking tests (6MWT) conducted within the six months before and after radiotherapy treatment. Results: In total, results from 144 patients were analyzed, with 11 of the patients receiving PR and radiotherapy simultaneously. Of the 133 patients in the control group, 33 were matched with 11 patients in the PR group. Changes in forced expiratory volume in one second (FEV1) and FEV1/forced vital capacity were significantly different between the PR group and the matched control group (240 mL vs. -10 mL, p=0.017 and 5.5% vs. 1.0%, p=0.038, respectively). The median distance of 6MWT in the PR group also increased significantly, from 407.5 m to 493.0 m after radiotherapy (p=0.017). Conclusion: Simultaneous PR improved pulmonary function, particularly in measures of FEV1, and exercise capacity for patients with lung or esophageal cancer even after radiotherapy treatment. These findings may provide an important base of knowledge for further large population studies with long-term follow-up analysis in the identification of the PR's effects during thoracic radiotherapy.

실리콘-알루미늄 몰 비의 변화에 따른 메타카올린 지오폴리머의 나노인덴테이션 결과 분석을 위한 가우시안 믹스쳐 모델의 활용 (Application of Gaussian Mixture Model for the Analysis of the Nanoindentation Test Results of the Metakaolin-based Geopolymer with Different Silicon-to-Aluminum Molar Ratio)

  • 박성우
    • 한국전산구조공학회논문집
    • /
    • 제35권2호
    • /
    • pp.101-107
    • /
    • 2022
  • 본 논문에서는 지오폴리머의 상변화를 관찰하기 위하여 나노인덴테이션 데이터를 가우시안 믹스쳐 모델로 분석하는 방법을 제시하였다. 지오폴리머는 일반 시멘트 대비 CO2 발생량을 줄일 수 있어 시멘트 대체 재료로써 많은 연구가 이루어지고 있다. 기존 연구들로부터 최적의 실리콘/알루미늄 비율을 찾았으나 1.8 초과에서 압축강도 저하의 원인은 아직 불분명하다. 본 연구에서는 실리콘/알루미늄 비율이 재료에 미치는 영향을 조사하고자 나노인덴테이션 실험을 수행하였다. 실험 결과를 가우시안 믹스쳐 모델로 상분석하였고, 실리콘/알루미늄 비율이 증가할수록 재료가 균질거동을 하는 것을 관찰할 수 있었다. 본 연구결과는 강도저하를 규명하는데 직접적인 근거로 활용될 수 있을 것으로 기대된다.

ALLOY STRUCTURE AND ANODIC FILM GROWTH ON RAPIDLY SOLIDIFIED AL-SI-BASED ALLOYS

  • Kim, H.S.;Thompson, G.E.;Wood, G.C.;Wright, I.G.;Maringer, R.E.
    • 한국표면공학회지
    • /
    • 제17권2호
    • /
    • pp.29-40
    • /
    • 1984
  • The structure of rapidly solidified Al-Si-based alloys and its relationship to subsequent anodic film growth in near neutral and acid solutions have been investigated. Solidification of the alloys proceeds via pre-dendritic nuclei, associated with rugosity of the casting surface, from which cellular-type growth, comprised of aluminium-rich material surrounded by silicon-containing material, emanates. Observation of ultramicrotomed sections of the alloys and their anodic films reveals the local oxidation of the silicon-rich phase and its incorporation into the anodic alumina film, formed in near neutral solutions. Such incorporation occurs but resultant isolation of the silicon-rich phase is not possible for anodizing in phosphoric acid, and a three-dimensional network of the oxidized silicon-containing phase, with continuing development of porous anodic alumina, is observed.

  • PDF

Carbon Nanoscrolls from CVD Grown Graphene

  • Jang, A-Rang;Shin, Hyeon-Suk;Kang, Dae-Joon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.574-574
    • /
    • 2012
  • We report a simple way of fabricating high-quality carbon nanoscrolls (CNSs) by taking advantage of strain relief due to large difference in strain at the interface of graphene and underlying layer. This method allows strain-controlled self rolling-up of monolayer graphene during etching process at predefined positions on SiO2/Si substrates by photolithography. The size and the length of the CNSs can be easily controlled by adjusting the thickness of the underlying layer and by pre-patterning. Raman spectroscopy studies show that the CNSs is free of significant defects, and the electronic structure and phonon dispersion are slightly different from those of two-dimensional graphene. The preparation of high-quality CNSs may open up new opportunities for both fundamental and applied research of CNSs.

  • PDF

Surface Morphology, Microstructure and Mechanical Properties of Thin Ag Films

  • Shugurov, Artur;Panin, Alexey;Chun, Hui-Gon;Oskomov, Konstantin
    • 한국분말재료학회지
    • /
    • 제10권3호
    • /
    • pp.190-194
    • /
    • 2003
  • Thin Ag films deposited onto $SiO_2/Si$ substrates by DC magnetron sputtering and thereafter annealed ,it temperatures 100-50$0^{\circ}C$ are investigated by scanning tunneling and atomic forte microscopy. It is shown that the film surface topography and microstructure are considerably changed as a result of annealing. To provide a quantitative estimation of the surface topography changes of Ag films the surface fractal dimension was calculated. Elasticity and hardness of the films are studied by a nanoindentation technique. The films are found to have value of elastic modulus close to that of bulk silver while their hardness and yield stress are essentially higher.

가스분무법에 의한 Fe계 비정질 분말의 제조와 볼밀링공정에 의한 연질 Cu 분말과의 복합화 및 SPS 거동 (I) - I. 가스분무 및 복합화 - (Production of Fe Amorphous Powders by Gas-atomization Process and Subsequent Spark Plasma Sintering of Fe Amorphous-ductile Cu Composite Powders Produced by Ball-milling Process (I) - I. Gas Atomization and Production of Composite Powders -)

  • 류호진;임재현;김지순;김진천;김휘준
    • 한국분말재료학회지
    • /
    • 제16권5호
    • /
    • pp.316-325
    • /
    • 2009
  • Fe based (Fe$_{68.2}$C$_{5.9}$Si$_{3.5}$B$_{6.7}$P$_{9.6}$Cr$_{2.1}$Mo$_{2.0}$Al$_{2.0}$) amorphous powder, which is a composition of iron blast cast slag, were produced by a gas atomization process, and sequently mixed with ductile Cu powder by a mechanical ball milling process. The experiment results show that the as-prepared Fe amorphous powders less than 90 $\mu$m in size has a fully amorphous phase and its weight fraction was about 73.7%. The as-atomized amorphous Fe powders had a complete spherical shape with very clean surface. Differential scanning calorimetric results of the as-atomized Fe powders less than 90 $\mu$m showed that the glass transition, T$_g$, onset crystallization, T$_x$, and super-cooled liquid range $\Delta$T=T$_x$-T$_g$ were 512, 548 and 36$^{\circ}C$, respectively. Fe amorphous powders were mixed and deformed well with 10 wt.% Cu by using AGO-2 high energy ball mill under 500 rpm.

Volumetric-Modulated Arc Radiotherapy Using Knowledge-Based Planning: Application to Spine Stereotactic Body Radiotherapy

  • Jeong, Chiyoung;Park, Jae Won;Kwak, Jungwon;Song, Si Yeol;Cho, Byungchul
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.94-103
    • /
    • 2019
  • Purpose: To evaluate the clinical feasibility of knowledge-based planning (KBP) for volumetric-modulated arc radiotherapy (VMAT) in spine stereotactic body radiotherapy (SBRT). Methods: Forty-eight VMAT plans for spine SBRT was studied. Two planning target volumes (PTVs) were defined for simultaneous integrated boost: PTV for boost (PTV-B: 27 Gy/3fractions) and PTV elective (PTV-E: 24 Gy/3fractions). The expert VMAT plans were manually generated by experienced planners. Twenty-six plans were used to train the KBP model using Varian RapidPlan. With the trained KBP model each KBP plan was automatically generated by an individual with little experience and compared with the expert plan (closed-loop validation). Twenty-two plans that had not been used for KBP model training were also compared with the KBP results (open-loop validation). Results: Although the minimal dose of PTV-B and PTV-E was lower and the maximal dose was higher than those of the expert plan, the difference was no larger than 0.7 Gy. In the closed-loop validation, D1.2cc, D0.35cc, and Dmean of the spinal cord was decreased by 0.9 Gy, 0.6 Gy, and 0.9 Gy, respectively, in the KBP plans (P<0.05). In the open-loop validation, only Dmean of the spinal cord was significantly decreased, by 0.5 Gy (P<0.05). Conclusions: The dose coverage and uniformity for PTV was slightly worse in the KBP for spine SBRT while the dose to the spinal cord was reduced, but the differences were small. Thus, inexperienced planners could easily generate a clinically feasible plan for spine SBRT by using KBP.

Accuracy Improvement of Boron Meter Adopting New Fitting Function and Multi-detector

  • Kong, Chidong;Lee, Hyunsuk;Tak, Taewoo;Lee, Deokjung;Kim, Si Hwan;Lyou, Seokjean
    • Nuclear Engineering and Technology
    • /
    • 제48권6호
    • /
    • pp.1360-1367
    • /
    • 2016
  • This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs) in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.