• 제목/요약/키워드: Ulsan Fault

검색결과 160건 처리시간 0.027초

Calculation of Distributed Magnetic Flux Density under the Stator-Turn Fault Condition

  • Kim, Kyung-Tae;Hur, Jin;Kim, Byeong-Woo
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.552-557
    • /
    • 2013
  • This paper proposed an analytical model for the distributed magnetic field analysis of interior permanent magnet-type blush-less direct current motors under the stator-turn fault condition using the winding function theory. Stator-turn faults cause significant changes in electric and magnetic characteristic. Therefore, many studies on stator-turn faults have been performed by simulation of the finite element method because of its non-linear characteristic. However, this is difficult to apply to on-line fault detection systems because the processing time of the finite element method is very long. Fault-tolerant control systems require diagnostic methods that have simple processing systems and can produce accurate information. Thus analytical modeling of a stator-turn fault has been performed using the winding function theory, and the distributed magnetic characteristics have been analyzed under the fault condition. The proposed analytical model was verified using the finite element method.

Simplified Impedance Modeling and Analysis for Inter-Turn Fault of IPM-type BLDC motor

  • Kim, Byeong-Woo;Kim, Kyung-Tae;Hur, Jin
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.10-18
    • /
    • 2012
  • This paper proposes a finite element method (FEM)-based model of an interior permanent magnet (IPM)-type BLDC motor having stator inter-turn faults. We also propose impedance modeling of the magnetic characteristics. By integrating the developed model with a current-controlled voltage source inverter (CCVSI) model, the distributed characteristics of an inter-turn fault operated by a six-switch inverter are investigated considering speed control. Moreover, this paper presents the flux density distribution and torque characteristics for analyzing the inter-turn fault of an IPM-type BLDC motor. Additionally, fault impedance is required to calculate the circulating current that causes magnetic distortion. Thus, this paper proposes a method for estimating the circulating current taking into account the voltage at the shorted turn and the rotating speed. The analysis data were verified experimentally.

임피던스 성분을 이용한 매입형 영구자석 전동기의 고정자 절연파괴 고장의 초기 검출 기법 (Early Detection Technique in IPM-type Motor with Stator-Turn Fault using Impedance Parameter)

  • 정채림;김경태;허진
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.612-619
    • /
    • 2013
  • This paper proposes an early diagnosis technique for the stator-turn fault (STF) in an interior permanent magnet (IPM)-type brushless DC (BLDC) motor using the impedance parameter. We have analyzed the varying characteristics owing to the STF through various experiments and the finite element method (FEM). As a result, we have presented a simple method for fault detection. This technique can be applied without requiring a fast Fourier transform (FFT) and the calculation of the negative-sequence impedance. The fault detection system works on the basis of the comparison the measured impedance with the database impedance. The variations in the characteristics owing to the STF as well as the proposed technique have been verified through the simulation and experiment.

The Alluvial Fan Surface Deformation of the Northern Part of the Ulsan(Bulguksa) Active Fault System in the Southeastern Korea

  • Yoon, Soon-Ock;Hwang, Sang-Il
    • 한국제4기학회지
    • /
    • 제18권2호통권23호
    • /
    • pp.5-16
    • /
    • 2004
  • The geomorphic deformation of the alluvial fans by tectonic movement was investigated along the lineaments of the northem part of the Ulsan(Bulguksa) fault system. Based on the aerial photographs interpretation and field surveys Ulsan fault system was identified as an active reverse fault which has displaced the Quatemary fan deposits. Buguksa fault system strikes for the direction of NW-SE and N-S. These two lineaments of active fault are crossing at Jinty village in Gyeongju city and the fault plane forms here almost vertical dip. The lateral pressures from the two directions have possibly influenced on the formation of the vertical dip at jinty villagy. It should be resulted from that the two pressures responsible for the active reverse fault at which the one with the NW-SE strike thrusts the hanging wall of Tohamsan block southwestward and the other pressure with the N-S strike thrusts it westward over the foot wall of the fan deposits. The marine oxygen isotope stage 8(0.30-0.25 Ma. BP) and stage 6(0.20-0.14 Ma. BP) are presumed to be the ages of high and middle surfaces of the alluvial fan, repectively. The vertical displacements on the high surfaces along the Bulguksa fault system are about 1.05 m at Ha-Dong, 9.5-10.5 m at Jinhyun-Dong, and about 10 m high at Jinty village. And the vertical displacement on the middle surface was measured about 6 m high at Ha-Dong. The average slip rate of vertical displacements is calculated about 0.03-0.43 mm/y.

  • PDF

울산단층대 주변의 단층 지형 및 선구조 분포 (Distribution of Fault-related Landforms and Lineaments Along the Ulsan Fault Zone)

  • 이광률;박충선;신재열
    • 한국지형학회지
    • /
    • 제25권3호
    • /
    • pp.89-103
    • /
    • 2018
  • This study presents results of analysis on fault-related landforms and the Quaternary fluvial landforms, which are important evidences for active faulting by identifying surface deformation, around the Ulsan Fault Zone. In addition, this study suggests lineament map and inferred active fault-line map based on analyzing linearity and continuity of these landforms and by compiling location information of existing active faults. We convince that quantitative tectonic-geomorphological analysis are an effective method for active faults tracking, in particular, considering the conditions of relatively low seismicity and surface ruptured-events in the Korean Peninsula compared to plate boundary active areas. However, research on active fault in South Korea is just an infant stage since the 1990s and requires accumulation of research achievements on development and application of various fault analysis techniques, analysing and standardizing linear structures.

고정자 절연파괴 고장에 의한 매입형 영구자석 BLDC 모터의 불가역 감자에 대한 동적해석 알고리즘 (Dynamic Analysis Algorithm of Irreversible Demagnetization of IPM-type Brushless DC Motor by Stator Turn Fault)

  • 이윤석;김경태;허진
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1661-1667
    • /
    • 2013
  • This paper studies the dynamic irreversible demagnetization characteristics of an interior permanent magnet (PM) brushless DC motor with a stator turn fault. A new algorithm, which is a finite element method (FEM) combined with a line voltage equation of the motor, is developed to analyze irreversible demagnetization under dynamic and transient states and considers a stator turn fault. The input current, circulating current, magnetic distribution characteristics, and operating property of the PM, including the irreversible demagnetization in the fault state, are analyzed using this algorithm by considering the magnetic saturation effect. The feasibility of the proposed method confirmed from the analysis results is verified via an experiment. Through this fault analysis, we can accurately check the fault phenomena of a PM motor against the demagnetization fault for fault prevention.

Active Fault Study of the Yangsan Fault System and Ulsan Fault System, Southeastern Part of the Korean Peninsula

  • 경재복;이기화
    • 지구물리
    • /
    • 제9권3호
    • /
    • pp.219-230
    • /
    • 2006
  • Since the key issue that 'the Yangsan fault is seismically an active fault" was raised in 1983, thegeological and geomorphological studies of active fault have been made by many researchers. These studies are mainly focused on the Yangsan fault system(YFS) and Ulsan fault system(UFS) due to many historical earthquakes occurred in this area. There are two different types of active faultings under the ENE-WSW horizontal stress field in the southeastern part of the Korean Peninsula. The NNE-trending YFS is the most prominent right-lateral strike-slip fault and has a continuous trace about 200 km long. Some part of this system has been active during the late Quaternary with evidences clearly recognized on both the northern (Yugyeri and Tosung-ri areas) and southern parts (Eonyang to Tongdosa area) of the YFS. in the southern part, the estimated vertical slip rate is about 0.02 - 0.07 mm/yr, and the lateral slip rate may be several times larger than the vertical rate. The most recent event occurred prior to deposition of Holocene alluvium, in the northern part, the fault trend locally changes to almost N-S, dips to the east and has reverse movement. The average vertical slip rate is estimated to be less than 0.1 mm/yr. The most recent event probably occurred after 1314 years BP (AD 536). The NNW-SSE (or N-S) trending UFS is a predominantly reverse fault that built up U-ie eastern mountain and has been active during U-ie late Quaternary. The fault trace is not straight but irregularly undulates along the foot of the mountain on the east. From the disturbed terraces along U-ie fault, the average vertical slip rate on U-iis system is estimated to be about 0.08.13mm/yr. The latest event is not well studied, but seems to have occurred after the last glacial maximum in the Malbang fault and 14,000 years BP in the Kalgok fault of the UFS. However, important issues such as fault segmentation, recurrence interval, age of Quaternary deposits need further studies.

  • PDF

전기, 전자탐사에 의한 경주남부 (입실지역)의 울산 단층 심부구조 (Deep structure of Ulsan fault by electric and EM surveys in ipsil area, South of Kyeongju)

  • 손호응
    • 자원환경지질
    • /
    • 제32권2호
    • /
    • pp.161-167
    • /
    • 1999
  • Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range of 10~100,000 Hz was mainly employed to study the deep subsurface configuration. High-frequency MT survey was performed at 70 points of spacing 30~50 m, making 3.8 km survey line. As a survey result, a 2-km-depth 2-D cross-section was achieved. It shows vertical and horizontal subsurface variations of resistivity values. Near-surface layer having low resistivity value becomes thicker eastward up to 800m. There is a steep low resistivity zone in the west side of survey line, and there exists two low resistivity zones dipping west in the east side of survey line. Two low resistivity zones are interpreted to be related to major movement pattern of the Ulsan fault. This suggests that major fault lines are developed on both peripheral sides of the broad fault zone.

  • PDF

울산단층북부 갈곡리 치실 지점의 마지막 단층 운동시기 결정 (Determination of the latest fault movement by trench survey at Galgok-Chisil site in the northern Ulsan fault system)

  • 최원학;장천중;정상대영;전중죽연
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.11-17
    • /
    • 2005
  • Along the Ulsan Fault System, many Quaternary faults have been reported and investigated with outcrop observation and trench excavation to clarify the neotectonic movements and fault parameters such as length, displacement, slip rate and recurrence interval. In the northern part of the Ulsan fault system, we have interpreted small scale(1:10,000) aerial photographs and extracted lineaments by geomophological features to select trench site. After precise field survey and tracing for lineaments, two trench sites at Galgokri, Gyeongju were selected on the lineament to elucidate the fault movement history. One is successful in finding faults but the other is not. In the Galgok-Chisil trench(3m(w) x 1.5m(d) x 10m(l)), very closed two Quaternary faults cut the alluvial deposits of which age shows about 10-3ka. More than three times of fault movements can be inferred by geologic structures and C-14 dating. Repeatedly fault movements had been occurred before 10 ka, between 10ka-4.9 ka, between 4.9-1.4 ka at Galgok-Chisil trench section.

  • PDF

울산단층대에서의 굴절파 속도이방성 연구 (Seismic Studies on Velocity Anisotropy in the Ulsan Fault Zone)

  • 이광자;김기영;김우혁;임창복
    • 지구물리
    • /
    • 제3권1호
    • /
    • pp.49-56
    • /
    • 2000
  • 울산단층의 단층분절 연구의 일환으로, 울산단층의 파쇄대로 추정되는 경주-울산간 7번국도와 인접한 지역 17개 측점에서 워커웨이 자료를 획득하였으며, 1-48 m의 옵셋구간에서 기록된 굴절파의 속도이방성을 측정하였다. 기록된 굴절 P파 속도는 평균 1787 m/s로 기반암의 풍화층 상부에서 굴절된 파로 해석되며, 속도이방성은 평균 0.056으로 구조선이 예상주향방향과 일치함을 간접적으로 시사한다. 경상북도와 경상남도의 도경계선를 기준으로 남쪽에서는 예상주향방향의 속도가 예상 경사방향보다 빠른 정상적인 이방성을 보이나, 북쪽으로는 단층의 주향이 여러 방향으로 갈라져있거나, 예상경사방향으로 발달된 구조선이 많이 발달해 있을 가능성이 높은 것으로 분석되었다. 이는 단층이 도경계선 부근을 경계로 울산단층이 분절되어 있을 가능성을 시사한다.

  • PDF