• 제목/요약/키워드: UV-rays

검색결과 147건 처리시간 0.027초

자외선 조사에 따른 태양전지 보호용 EVA의 열화 (The degradation of EVA for the protection of solar cell by UV-rays irradiation)

  • 김규조;연복희;김승환;김완태;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.177-180
    • /
    • 2000
  • We studied the degradation of EVA for the protection of solar cell by UV-rays irradiation. We investigated the reduction of electrical efficiency, photo transmmitance and degradation of EVA by UV-rays irradiation. We utilized the UV irradiation equiped with fluorescent 313nm UV lamp and radiated for 400 hours. For the chemial analysis, we used the UV-vis spectrometer, XPS and examined the degradation mechanism by UV irradiation. It is found that the discolored phenomena, the decrease of photo transmmitance and oxidation reaction is occured by UV irradiation on the EVA sample for the protection of solar cell.

  • PDF

인위적인 자외선 조사량에 따른 폴리머애자에서의 코로나 방전 특성 (A Study of Corona Discharge in Polymer Insulators by Artificial UV Radiation)

  • 김영석;최명일;김종민;방선배;송길목;곽동순
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.643-648
    • /
    • 2013
  • In this study, degradation was observed by irradiating UV rays to the polymer insulators which have been widely used in outdoor electric power facilities. For an indoor accelerated UV test, 0.55 w/m2 of UV rays were applied using a xenon-arc method. A UV detection system with 65 ${\phi}mm$ in diameter, 100 mm in length and 1.0 of brightness (F/#) has been designed. Even though efflorescence on the surface of polymer insulators wasn't observed according to the accelerated UV test. UV rays were detected at around 50% and 40% of insulation breakdown in EPDM and silicone-type insulators respectively. As degradation continued because of an indoor accelerated UV test, breakdown voltage with which UV rays can be detected in an early stage decreased as well. A silicone polymer insulator would be severer than EPDM polymer insulator in terms of surface degradation because of UV strength against $V_m/V_{BD}$ was high in silicone polymer insulators. UV strength in silicone-type insulators increased at 1,000 $kJ/m^2$ because contact angle at the intial stage sharply decreased to from $113^{\circ}$ to $92.1^{\circ}$.

A Study on the Relationship between Ultraviolet Rays and Skin Color Using a Photoplethysmography Sensor

  • So-Yae Hur;Sun-Jib Kim
    • International Journal of Advanced Culture Technology
    • /
    • 제11권1호
    • /
    • pp.363-369
    • /
    • 2023
  • In this study, to check the function of managing the severity of ultraviolet rays with a smart watch, a popular health care IT device, It was tested whether measuring heart rate using a PPG(Photoplethysmography) sensor representatively used in a smart watch could tell skin changes caused by ultraviolet rays. Through this experiment, we examined the possibility that the skin color tanned by ultraviolet rays can be determined only by the heart rate measurement function of the PPG sensor. In addition, the possibility of expanding the heart rate measurement function of the PPG sensor to the use of skin condition management was considered. we used an Arduino-based reflective PPG sensor to measure changes in heart rate by selecting body sites with high and low UV rays exposure. A significant value was derived through tests considering factors such as gender, UV exposure, and age. As a result, the study identified the possibility of adding ultraviolet rays and skincare items to future smart watch healthcare items and the possibility of expanding skin measurement methods. It is also possible to suggest the direction of future research.

IR Cut-Off Filter가 차단하지 못한 미량의 적외선이 디지털화상에 미치는 영향 분석 (The analysis of the Effect the Minute Quantities of Infrared Rays that Were not Filtered by IR Cut-Off Filter has on Digital Images)

  • 이용환;박세원;홍정의
    • 한국콘텐츠학회논문지
    • /
    • 제11권5호
    • /
    • pp.205-215
    • /
    • 2011
  • 분광특성의 차이로 필름은 자외선에 민감한데 반해 디지털 카메라의 센서는 적외선에 굉장히 민감하다. 이에 따라 CCD 또는 CMOS를 사용하는 모든 디지털 카메라에는 IR Cut-Off Filter가 센서전면에 장착되어 있다. 이상적으로 100% 적외선을 차단하여야 하지만 실험 결과 완전히 적외선을 차단하지 못하고 있었으며, 각 카메라마다 적외선 투과량 또한 달랐다. 따라서 본 연구는 디지털 카메라에 장착되어 있는 IR Cut-Off Filter의 기계적 특성에 의해 투과되는 미량의 적외선이 디지털 화상이미지에 끼치는 영향을 분석하는 데 그 목적이 있다. UV필터를 장착한 상태(적외선 투과상태)와 UV-IR필터를 장착한 상태(적외선미투과상태)를 비교분석한 결과, 잡음(Noise)과 색 재현력 평가에서는 그 차이가 미세하거나 거의 동등한 수준이지만, 동적 폭(Dynamic Range)과 해상도에는 IR Cut-Off Filter를 통해 투과되는 미량의 적외선이 어느 정도 영향이 있음을 확인할 수 있었다.

다중층 나노구조체를 통한 열차단 특성 제어 (Analysis of suppressed thermal conductivity using multiple nanoparticle layers)

  • 노태호;심이레
    • 한국표면공학회지
    • /
    • 제56권4호
    • /
    • pp.233-242
    • /
    • 2023
  • In recent years, energy-management studies in buildings have proven useful for energy savings. Typically, during heating and cooling, the energy from a given building is lost through its windows. Generally, to block the entry of ultraviolet (UV) and infrared (IR) rays, thin films of deposited metals or metal oxides are used, and the blocking of UV and IR rays by these thin films depends on the materials deposited on them. Therefore, by controlling the thicknesses and densities of the thin films, improving the transmittance of visible light and the blocking of heat rays such as UV and IR may be possible. Such improvements can be realized not only by changing the two-dimensional thin films but also by altering the zero-dimensional (0-D) nanostructures deposited on the films. In this study, 0-D nanoparticles were synthesized using a sol -gel procedure. The synthesized nanoparticles were deposited as deep coatings on polymer and glass substrates. Through spectral analysis in the UV-visible (vis) region, thin-film layers of deposited zinc oxide nanoparticles blocked >95 % of UV rays. For high transmittance in the visible-light region and low transmittance in the IR and UV regions, hybrid multiple layers of silica nanoparticles, zinc oxide particles, and fluorine-doped tin oxide nanoparticles were formed on glass and polymer substrates. Spectrophotometry in the UV-vis-near-IR regions revealed that the substrates prevented heat loss well. The glass and polymer substrates achieved transmittance values of 80 % in the visible-light region, 50 % to 60 % in the IR region, and 90 % in the UV region.

자외선조사에 의한 Cation화 면직물의 문양염색 (Pattern Dyeing of Cationized Cotton Fabrics by Ultra Violet Rays Irradiation)

  • 김인희;이인석;남성우
    • 한국염색가공학회지
    • /
    • 제14권2호
    • /
    • pp.77-77
    • /
    • 2002
  • Cotton fabrics dipped in cationic agent(3-chloro-2-hydroxypropyl trimethyl ammonium chloride) were irradiated with deep Ultra Violet Rays(UV), in the region of UV-C using the low pressure mercury lamp. The chemical changes of cationized cotton fabric surfaces were investigated by FT-IR analysis. The dyeabilities of the irradiated portions were investigated by dyeing with acid dyes. Deep UV(UV-C) irradiation broke O-H bonds in cotton fiber and oxidized the fibers. The dyeability of the UV irradiated portion were different from that of the portion not irradiated. Various pattern were gained from one bath dig dyeing by pattern mask. The tensile strengths of cotton fabrics were decreased in the UV irradiated portion. Washing fastness of cotton dyeings were good about 3∼4 grade and light fastness were fair about 2∼3 grade.

자외선조사에 의한 Cation화 면직물의 문양염색 (Pattern Dyeing of Cationized Cotton Fabrics by Ultra Violet Rays Irradiation)

  • 김인회;이인석;남성우
    • 한국염색가공학회지
    • /
    • 제14권2호
    • /
    • pp.1-8
    • /
    • 2002
  • Cotton fabrics dipped in cationic agent(3-chloro-2-hydroxypropyl trimethyl ammonium chloride) were irradiated with deep Ultra Violet Rays(UV), in the region of UV-C using the low pressure mercury lamp. The chemical changes of cationized cotton fabric surfaces were investigated by FT-IR analysis. The dyeabilities of the irradiated portions were investigated by dyeing with acid dyes. Deep UV(UV-C) irradiation broke O-H bonds in cotton fiber and oxidized the fibers. The dyeability of the UV irradiated portion were different from that of the portion not irradiated. Various pattern were gained from one bath dig dyeing by pattern mask. The tensile strengths of cotton fabrics were decreased in the UV irradiated portion. Washing fastness of cotton dyeings were good about 3∼4 grade and light fastness were fair about 2∼3 grade.

UV 센서를 이용한 절연애자의 코로나 방전 측정 및 자외선 이미지의 비교 (Comparison of UV images and Measurement of the Corona Discharge from Insulators using the UV Sensor)

  • 김영석;최명일;김종민;방선배;송길목
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.899-904
    • /
    • 2011
  • Inspections and diagnoses of corona discharge are important in order to prevent electrical faults of external insulation in power systems. This paper studies a measurement of ultra-violet rays(UV) strength of corona discharges on insulators using a UV sensor with an optic lens. The data has been compared with the images of a UV camera. The UV sensor estimated that DC voltage needed to be set at 700V for accurate data analysis of the properties of UV detected during corona discharge. UV was generated at 60kV when the corona discharge occurred. UV strength and images of UV increased at a high voltage. The image area of the UV using a UV camera and the detection of UV using a UV sensor have shown, that the polymer insulator mounted on a live part must be checked when the applied voltage on the good polymer insulator is greater than 37.5% of its breakdown voltage.

자외선 조사를 이용한 다단계 컨베이어 자동 살균기 개발에 관한 연구 (The developement of multi-layer sterilizer using Ultra Violet irradiation)

  • 김영철;유광호;정영국;김하석;정태성;윤복선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3060-3063
    • /
    • 1999
  • We made a multi-layer conveyor sterilizing system using UV rays to prolong a storage period of dried marine products. The system is composed of 5 layer conveyor belt of 3 m long each, thus 15 m long in total. It is designed to radiate UV rays for 10 minutes the dried marine products, and can process 300 kg/hour. Eight UV lamps of 30 cm long and 15 W of power with 254 nm wave length are installed in parallel, 15 cm high above in each belt, and 40 lamps in total. The whole system is covered by 1 mm thick metal plates to block the UV rays except a front side which is covered with 5 mm thick plastic plates coated with UV protection film to survey inside of the system. A sterile ratio is about 99.97% with 10 minutes sterilization using this system.

  • PDF

인체 감지 제어 기능을 갖는 UV LED Bar의 최적 설계 (The UV LED Bar Optimal Design with Human Detection and Control Function)

  • 김창선;이재학;고영진
    • 한국전자통신학회논문지
    • /
    • 제12권6호
    • /
    • pp.1219-1226
    • /
    • 2017
  • 본 논문에서는 다용도로 사용 가능한 UV LED 바의 최적설계를 하였다. UV LED는 자외선을 방출하기 때문에 사용목적상 일정하게 자외선을 방출하는 것이 중요하다. 일정한 자외선이 방출되기 위해서는 동작 가능 입력 전압 범위 내에서 정전류원으로 구동되어야 하고 자외선 활용 특성 상 자외선 방출 유지 시간이 길기 때문에 방열이 특히 중요하다. 따라서 소비전력이 최소화 되도록 설계해야 한다. 또한 인체 보호가 필수적이기 때문에 거리 감지 센서와 블루투스를 이용해 인체 감지 여부에 따라 동작할 수 있게 알고리즘을 구성하였다. 자외선 UVA를 방출하기 위해 365nm UV LED 3개가 직렬로 사용되었으며 입력 전압 12V와 정전류 500mA에서 동작하며 효율은 87.5%, 소비전력은 6.006W이다. 그리고 자외선 조사량은 루트론 계측기로 측정하였을 경우 10cm 거리에서 $5.35mW/cm^2$으로 측정 되었다.