• Title/Summary/Keyword: UV sensor

Search Result 238, Processing Time 0.03 seconds

UV ray protective function and wear sensation of garment for plastichouse worker (비닐하우스용 작업복의 자외선 차단 성능과 착용감 연구)

  • 최정화;백윤정
    • Korean Journal of Rural Living Science
    • /
    • v.6 no.1
    • /
    • pp.25-30
    • /
    • 1995
  • This study was designed to obtain the basic data developing the UV ray protective garments for the plastichouse workers. Two subjects were volunteered for 1hr. wear test in plastic house, and the ensembles was composed of one of three kinds blouse (UV blocking blouse, polyester/cotton 47/53 blouse, and polyester blouse), shorts, sleeveless undershirts, pants and socks. The measurements were rectal temperature, skin temperature, microclimate inside clothing, subjective sensation, and the colour difference of UV sensor. The results were as follows: 1. Microclimate especially, temperature inside clothing of polyester blouse was the highest among the garments. And UV-proof polyester blouse showed the lower mean skin temperature and microclimate than others. Showing the highest sweat volume. 2. No significant difference on UV ray blocking function among 3 kinds of garment was shown. 3. We could conform that in spring for the plastic house wぉw s garment low thermal insulating value and wide covering area were more important factors than UV blocking function of fabric.

  • PDF

Corona19 Quarantine Bus Shelter with CO2 and Body Temperature Sensor (CO2 센서와 체온 센서를 이용한 코로나19 방역 버스 쉘터)

  • Park, Byeong-Yoon;Lee, Hyeon-Min;Tran, Van-Son;Nguyen, Minh-Tuan;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.981-990
    • /
    • 2021
  • Corona 19 quarantine is often not implemented at degraded bus stops. We conducted this study to improve these problems. The inside and outside of the shelter can be sterilized with UV photocatalyst coating to maintain a hygienic and clean shelter, and passengers can breathe smoothly by reducing carbon dioxide in the shelter using CO2 sensors and fans. It is also expected that the body temperature can be measured using a body temperature sensor to prevent more than 20% of the spread of the coronavirus in the shelter by isolating suspected coronavirus patients in the first place. When the temperature measurement distance was less than 10cm, the accuracy of the temperature measurement was 98.9%. You can communicate your intention to ride safely and clearly without contacting the bus driver by using a ride bell that uses wireless communication inside the shelter.

UV/IR flame detector using Microprocessor (마이크로프로세서를 사용한 UV/IR 불곶 감지기)

  • 박성진;임병현;임종연;김명원;윤길호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

Real-time Spectroscopic Methods for Analysis of Organic Compounds in Water

  • Kim, Chihoon;Ji, Taeksoo
    • Current Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.336-341
    • /
    • 2019
  • This paper proposes an optical system where the organic compound content in water is determined by using an ultraviolet (UV) LED (280 nm) and photodetector. The results obtained by the proposed prototype LED spectroscopy system, which includes a single photodetector and two parallel sample holders, are calculated by applying partial least square regression; the values are highly correlated with the actual concentrations of potassium hydrogen phthalate solutions, with an adjusted coefficient of determination about 0.996. Moreover, the total organic carbon values derived from the UV-Vis spectrometer of real samples (lake, river and sea water) differed little from those obtained by the LED spectroscopy. We confirm that the fast, sensitive, and compact LED sensor system can be readily configured for real-time monitoring of organic compounds in water.

Solar Ultraviolet Irradiance Incident on a Horizontal Surface At taegu In Korea During 1995-1998 : (I) Ultraviolet -A

  • Suh, Kye-Hong
    • Journal of Photoscience
    • /
    • v.6 no.1
    • /
    • pp.1-3
    • /
    • 1999
  • Solar ultraviolet-A (UV-A) irradiances indicent on a horizontal surface at Taegu of Korea during 1995-1998 were calculated with 5 min averages of measurements taken every 30 seconds by a broadband UV- A sensor. The maximum and minimum of monthly averages of daily UV-A dose were 499.37 KJ m-2 day-1 inJuly and 171.09 KJ m--2 day-1 in December for 4 years of the observation period. The maxima of daily UV-A dose and instandaneous UV-A were observed as 846.46KJ m-2 day-1 June 7, 1998 and 37.22 W m-2 at 12 : 15, July 16, 1998, respectively. Increasing trends in annual maxima of daily UV-A dose and instantaneous UV-A were averaged to 6.4% and 6.7% , respectively, per year during 1995-1998 at Taegu, Korea.

  • PDF

Implemention of Power On/Off Set by Using Fire Flame Sensor UV TRON and Driving Circuit (화재 감지 센서와 구동 회로를 이용한 전원 개폐장치의 구현)

  • Kim, Y.H.;Son, W.T.;Lee, H.K.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.231-234
    • /
    • 2005
  • In this paper, propose device that all of AC Power could do switching because uses fire flame sensor(UV TRON R2868) and sensor driving circuit. Used OrCAD program for analysis of consisted Power On/Off Set, and this manufactures and experimented driving circuit actually. The experimental result is considered that can refer to data of circuit design in case of apply to actual field of practical use that need alarm after sense flame, and special quality that give an alarm sensing flame in experiment wave and given environment relatively stable. With this result Power On/off Set and that action of embodied serrounding system can utilize actually verify.

  • PDF

Improvement of a UV/Ozone Duplex Sterilizer (UV/Ozone 복합 살균기의 살균력 개선 연구)

  • Jee, Jung-Eun;Yang, Won-Kyun;Park, Eun-Chul;Kim, Kang-Suk;Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.2
    • /
    • pp.76-82
    • /
    • 2008
  • We investigated sterilization characteristics of UV lights by counting the number of bacteria units with varying sterilization time and distance from the light source. We focused on an idea that UV light of 184.9 nm could generate ozone and developed a new sterilizer. The UV-ozone duplex system sterilized bacteria faster than UV-only sterilizers. To reduce shadowing effects by target objects, we used UV transparent quartz plate as a support and put a reflecting plate. Distribution of UV irradiation intensity and ozone supply were analyzed by a 3D model and measured by a semiconductor UV sensor. But even with an Al reflector, multi-layered pens could not be treated properly from UV irradiation only. Ozone generating lamp could treat more uniformly multi-layered pens with a stirring fan by supplying ozone to shadowed surfaces.