• Title/Summary/Keyword: UV meter

Search Result 56, Processing Time 0.028 seconds

Analysis of Image and Development of UV Corona Camera for High-Voltage Discharge Detection (고전압 방전 검출용 자외선 코로나 카메라 개발 및 방전 이미지 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.69-74
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV image. UV camera developed a $6.4[^{\circ}]{\times}4.8[^{\circ}]$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. UV camera to measure the discharge count and the UV image was developed, compared with a commercial camera, there was no significant difference. In salt spray environments breakdown voltage was lower than the normal state, thereby discharging the image was rapidly growing phenomenon.

The effect and stability of Retinyl Palmitate(RP) in W/O, W/S, O/W, MLV(Multilamellar Vesicles) cream (W/O, W/S, O/W, MLV(Multilamellar Vesicles) TYPE에서 Retinyl Palmitate(RP)의 열적 안정성과 효능, 효과에 관한 연구)

  • 지홍근;서봉석
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.22 no.1
    • /
    • pp.40-59
    • /
    • 1996
  • Retinyl Palmitate, the skin normalzer, is useful to promote greater skin elasticity, to diminish lipid peroxidation and skin roughness following UV exposure, and promote a youthfull general skin appearance. We knew that the reduction of retinyl palmitate in W/O, W/S, O/W, MLV cream was caused by variable compound factors. Among the retinoids, we chose retinyl palmitate and studied the stability behavior of retinyl palmitate is liposomed. Furthermore, HPLC, CHROMA METERS, LASER SIGHT SCATTERING SYSTEM and FREEZE FRACTURE SCANNING ELECTROM MICROSCOPY was used to analyzing the stability and efficacy of UV and heat.

  • PDF

Low temperature UV-assisted rapid thermal processing of (Ba,Sr)$TiO_3$ thin films (저온에서 (Ba,Sr)$TiO_3$ 박막의 UV를 이용한 RTP에 관한 연구)

  • Cho, Kwang-Hwan;Kang, Chong-Yun;Yoon, Seok-Jin;Lee, Young-Pak
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.234-234
    • /
    • 2008
  • Chemically homogeneous $Ba_{0.6}Sr_{0.4}TiO_3$ (BST) sols were synthesized using barium acetate, strontium acetate, and titanium isoproxide as starting materials. BST thin films of thickness 340 nm were deposited on Pt/$TiO_2/SiO_2$/Si and alumina substrates using spin coating method. The technique used for the processing of these films was Ultraviolet (UV) sol-gel photoannealing, using phto-sensitivity precursor solutions and UV-assisted rapid thermal processing(UV-RTP). The crystallization behaviour of the BST sols and thin films was studied by differential thermal analysis (DTA) and X-ray diffraction (XRD). Variation of permittivity and dielectric loss were measured in LCR-meter, model HP 4394A.

  • PDF

THE DEVELOPMENT OF A UV FLAME DETECTOR FOR THE AUTOMATIC FIRE SUPPRESSION SYSTEM FOR ENGINE COMPARTMENT FIRES

  • Lim, Sung-Mook;Jung, Ki-Chang;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.590-597
    • /
    • 1997
  • In this work, a new type of UV flame detection system was developed. In order to measure the performance of UV flame detector, various kinds of experiments was performed. The results show that the maximum response time of the UV flame detector is 0.2 seconds when the detection distance is one meter The advantages of this system include wide area, high speed response and high sensitivity. After testing the W flame detector in engine compartment it detected fire within 0.09 seconds and extinguished within 5 seconds. Hence, the UV flame detector can be applied in automatic fire suppression system for automobiles.

  • PDF

Analysis of Properties of UV Corona on Insulator in Salt Water Environments (염수 환경 열화 상태를 모의한 절연애자의 자외선 코로나 특성 분석)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok;Lee, Myeong-Jun;Lee, Woo-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1590-1591
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV camera. UV camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The UV camera was developed and measured using a UV image, as applied voltage increased ultraviolet images of the phenomenon could be obtained. And we investigated properties of UV corona image on insulator in salt water environments. From the results, the breakdown voltage was decreased and UV images were taken at low voltages and the UV image is rapidly increased with increasing High voltage.

  • PDF

Development of UV-IR Camera using IR Module and Improved UV Filter Transmittance (투과율 향상 UV 필터와 IR 모듈을 이용한 자외선-적외선(UV-IR) 카메라 개발)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il;Kim, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.37-43
    • /
    • 2012
  • UV-IR diagnostic technology is being used for predictive maintenance of high voltage equipment together with IR-thermography and ultrasonic devices. In this paper, the UV-IR camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. UV-IR camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. In a distance of 5m with the UV-IR it is possible to detect partial discharge with a PD level of 2.5 pC and a RIV(Radio Influence Voltage) level of $3.6dB{\mu}V$.

The optical characteristic of Fabry-Perot interferometer filter for UV meter (UV meter용 패브리-페로 간섭필터 제작 및 광학특성연구)

  • Park, Moon-Chan;Jung, Boo-Young;Choi, Hae-Jung;Chen, Ko-Hsien;Hwangbo, Chang-Kwon;Kim, Hyung-Doo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.463-471
    • /
    • 2004
  • The Fabry-Perot interferometer filters for UV meter were designed using the design program of optical thin films. From the data obtained, two filters were fabricated. The transmittance of two filter were measured by spectrophotometer in order to analysis their optical property. The transmittance was controlled by the thickness of Ag reflector and the wavelength of the transmission was controlled by the thickness of $SiO_2$ spacer. The two UV filters were fabricated by the RF magnetron sputtering which are the multilayers of [air/$SiO_2$(174.6 nm)|Ag(78 nm)|$SiO_2$(68 nm)|Ag(78 nm)|Cr(5 nm)|glass] and [air/$SiO_2$(174.6 nm)|Ag(S8 nm)|$SiO_2$(56 nm)|Ag(58 nm)|Cr(S nm)|glass]. One filter has the maximum transmittance of 6% at the about 370nm and it has the transmittance of below 0.2% at 400nm. The other filter can be found that the transmittance is increased as the thickness of Ag is decreased and the wavelength of the transmission is controlled by the thickness of $SiO_2$ spacer layer.

  • PDF

Development of UV Corona Camera for the Detecting of Discharge on Power Facility using UV Transmittance Improvement Filter (UV 투과율 향상 필터 기술을 이용한 전력설비 방전 검출용 자외선 코로나 카메라 개발)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1656-1661
    • /
    • 2012
  • UV inspection technology is being used for predictive maintenance of power facility together with IR-thermography and ultrasonic devices. In this paper, the UV corona camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. The UV corona camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The transmission between 250 to 280nm was 11% ($12.5%{\times}88%{\times}98%$) by combing the transmission on absorption film, window and other filter(UG 5, nickel sulphate and so on). In a distance of 5m with the UV corona camera it is possible to detect partial discharge with a PD level of 2.5pC and a RIV level of $3.6dB{\mu}V$.