• Title/Summary/Keyword: UV Detector

Search Result 336, Processing Time 0.03 seconds

The Development of UV-IR Combination Flame Detector (UV-IR 복합형 화재감지장치 개발)

  • 이복영;권오승;정창기;박상태
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of the fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage so that fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to activate a heat detector. In this case the most effective criterion for automatic fire detection is the flame. According to the fire regulation of korea, the compulsory standard provided that a flame detector shall be installed in a place that the attachment height of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The results of the research and development are discriminated between a flame and other radiant emitters, developed a UV detector tube contains an inert gas which absorbs UV radiation, developed PZT pyroelectric element is based on the use of photovoltanic cell, developed IR band-pass filter that only allow a 4.3 $\mu\textrm{m}$ radiation wavelength to reach the sensors and developed UV-IR combination flame detector combined into a single detection device.

  • PDF

UV Detector with Porous Si (Porous Si을 이용한 UV Detector)

  • Ko, Joo-Yul;Min, Nam-Ki;Kim, Suk-Ki;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1516-1517
    • /
    • 2000
  • 본 논문에서는 Porous Si(PSi)의 Photoluminescence(PL)특성을 이용한 UV detector를 이론적으로 고찰하곤 제작하였다. PSi의 PL에 의해 발생하는 빛의 피크 파장과 photodiode의 흡수영역을 최적화하여 UV detector의 효율을 극대화 시켰다. 제작된 PSi detector는 기존의 Si에 비해 반응 표면적을 증가시킬 수 있다는 장점이 있어 optical biosensor에 응용이 기대 된다.

  • PDF

THE DEVELOPMENT OF A UV FLAME DETECTOR FOR THE AUTOMATIC FIRE SUPPRESSION SYSTEM FOR ENGINE COMPARTMENT FIRES

  • Lim, Sung-Mook;Jung, Ki-Chang;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.590-597
    • /
    • 1997
  • In this work, a new type of UV flame detection system was developed. In order to measure the performance of UV flame detector, various kinds of experiments was performed. The results show that the maximum response time of the UV flame detector is 0.2 seconds when the detection distance is one meter The advantages of this system include wide area, high speed response and high sensitivity. After testing the W flame detector in engine compartment it detected fire within 0.09 seconds and extinguished within 5 seconds. Hence, the UV flame detector can be applied in automatic fire suppression system for automobiles.

  • PDF

Comparison of Analysis Methods for Ammonia from Swine Production Facilities

  • Kim, Ki Y.;Choi, Hong L.;Kim, Chi N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.11
    • /
    • pp.1608-1614
    • /
    • 2004
  • This study was performed to evaluate the accuracy, validation and applicability of UV spectrophotometer (UV), Ion Chromatography (IC), and Detector tube (DT) methods for measuring ammonia (NH3) concentration in a swine confinement house and swine slurry storage tank. The mean values of $NH_{3}$ emitted from the house and slurry were 5.333 ppm and 42.192 ppm for the IC method; 4.13 ppm and 36.29 ppm for the Detector tube; and 5.417 ppm and 34.193 ppm for the UV method. The accuracy and the correlation of an ammonia level analyzed by the IC method compared to the UV method were 98% and 0.998($R^{2}$) in the swine confinement house and 94% and 0.997($R^{2}$) in the swine slurry storage tank. On the other hand, those of ammonia level measured by the Detector tube compared to the UV method were 77% and 0.957($R^{2}$) in the swine confinement house and 82% and 0.941($R^{2}$) in the swine slurry storage tank. This indicated that the accuracy and the correlation of the IC method compared to the UV method were higher than those of the Detector tube method compared to the UV method. Therefore, it was concluded that the IC method was more accurate in measuring ammonia concentration in a swine house and a swine slurry storage tank. The Detector tube method should not be applied to the swine slurry storage tank in which ammonia concentration is generally higher than 30 ppm because low accuracy is caused by a gross space between scales inscribed in the Detector tube.

Influence of Dust Environment on the Detection Capability of Ultraviolet Flame Detector (UV 화염감지기의 감지성능에 대한 분진분위기의 영향)

  • Kim Hong;Hu Rui
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.113-119
    • /
    • 1997
  • The detection capability of UV flame detector in dust environment would be impaired. In this study, an experiment was conducted, in an effort to further understand the behavior of UV flame detector and to evaluate its detection capability in industry dust environment. Detergent powder, coal powder and dry extinguishing agent were selected as dust sources. Flaming sources include propane and gasoline flame. Experiment results indicate that dust can cause remarkable attenuation of UV flame radiation. The concentration of dust and the length of air layer where dust dispersed determine the reduction of radiation intensity. On the other hand, the attenuation of UV radiation also depends on the chemical and Physical properties of dust.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

The development of UV falme detector (UV 화재감지장치 개발)

  • Gwon, O-Seung;Jeong, Chang-Gi;Lee, Bok-Yeong
    • Fire Protection Technology
    • /
    • s.28
    • /
    • pp.48-54
    • /
    • 2000
  • The technique detects radiant energy form a flaming fire of fuels contained carbonaceous material can be applied to fast growing fires. This technique applied detectors are ultimately effective when early detecting fire alarm system is required or the smoke and heat detectors can not applied. In Korea Fire regulation, a flame detector should be install in case that the installation height is higher than 20[m], chemical plant, hangar refinery. Therefore it is really necessary that a flame detector has to be developed as soon as possible. With foundation technique of flame detector, ideal sensing element and stable circuit design, a trial UV flame detector is manufactured. The stable and reliable technique of flame detector is established through the repeateed perfomance test and modification. An early detecting fire alarm device is developed through the modification, supplement of the structure and circuit. Results of the R & D for the manufacture of an excellent flame detecting device is carried out with the establishment of technique for the mass production and the qualified manufacturing process.

  • PDF

Fabrication of Disposable Light Exposure Detector Kit using UV Curable Hydrogels (자외선 경화 하이드로겔을 사용한 일회용 빛 노출 검출 키트의 제조와 특성분석)

  • Kim, Young Ho;Kim, Gyu-Man;Dang, Trung Dung;Choi, Jin Ho;Kim, Hwan-Gon;Park, Sangju;Lee, Sang Hak
    • Applied Chemistry
    • /
    • v.15 no.1
    • /
    • pp.17-20
    • /
    • 2011
  • A disposable light exposure detector kit has been developed by UV curing of a hydrogel material. The devised light exposure detector kit consisted of light sensitive structures, bottom plate, character sheet and sticky back plate. A light exposure detector kit has a serial light sensitive structures that contain various light sensitive dyes such as rhodamine and fluorescein. The light sensitive structure composed of UV curable hydrogel polymer material as a supporing material and photosensitive dye in a certain concentration. The fabrication procedure of the ligh exposure detector kit is very simple and fast due to UV curing procedure of a photopolymerizable hydrogel material such as poly(ethylene glycol) methyl ether acrylate (PEGMEA) and poly(ethylene glycol) diacrylate (PEGDA) with a photosensitive dye. By the proposed fabrication method, various size and shape of a light exposure detector kit could be fabricated using a flexible elastomer mold. Due to a fast and inexpensive fabrication method, the light exposure detector kit could be use a single use for various industrial applications. According to light irradation, the light sensitive structure on a light exposure detector kit could be lose its color by decomposition of a photosensitive dye chemical in the structure. Thus the amount of the exposed light on a substrate could easily be recognised by changing color or transparency of the structure.

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

UV/IR flame detector using Microprocessor (마이크로프로세서를 사용한 UV/IR 불곶 감지기)

  • 박성진;임병현;임종연;김명원;윤길호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF