• Title/Summary/Keyword: UV Camera

Search Result 64, Processing Time 0.045 seconds

Implementation of Multi-functional Type Condition Monitoring System for Railway Catenary Systems (전기철도 전차선로의 설치 상태 판단을 위한 복합검측 기술 구현)

  • Park, Young;Lee, Kiwon;Park, Shin Young;Park, June Young;Choi, Won Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1406-1410
    • /
    • 2015
  • The railway catenary systems consist of a complex structure, electrical and mechanical conditions are exposed to dangerous environment due to current collection between pantograph and catenary systems. These two types of conditions for the catenary systems are critically assessed for management and are becoming increasingly more dependent on reliable inspection system. In this paper, a new measurement system which enables inspection of catenary faults was studied and implemented. The system uses wavelength band of ultraviolet (UV) and IR (Infrared) to measure the insulation of corona and temperature of catenary wire. In order to determine the sensitivity of implemented system, the performance test such as distance detection range of UV camera and temperature resolution of IR camera were conducted, respectively. The field test of development system was also conducted in metro and high-speed line using mobile type UV and IR multi-composited measurement systems.

WFC3 study on the early-type galaxy NGC4150

  • Jeong, Hyun-Jin;Yi, Suk-Young K.;Crockett, R. Mark;Kaviraj, Sugata
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.28.1-28.1
    • /
    • 2010
  • Recent surveys have shown that many early-type galaxies have signatures of ongoing or recent star formation (RSF). These RSF galaxies show blue integrated UV-optical colours that set them aside in the NUV integrated colour-magnitude relation. Among them, NGC 4150 has been observed using the Wide Field Camera 3 (WFC3) on board the Hubble Space Telescope to inspect the galaxy with higher spatial resolution. In the WFC3 data, the galaxy reveals ubiquitous near-UV emission and remarkable dusty substructure. Our analysis shows this galaxy to lie in the near-UV green valley, and its pixel-by-pixel photometry exhibits a narrow range of UV-optical colours that are similar to those of nearby E+A (post-starburst) galaxies, and lie between those of M83 (an actively star-forming spiral) and the local quiescent early-type galaxy population. This work reaffirms our hypothesis that minor mergers play a significant role in the evolution of early-type galaxies at late epochs.

  • PDF

Localization System for Mobile Robot Using Electric Compass and Tracking IR Light Source (전자 나침반과 적외선 광원 추적을 이용한 이동로봇용 위치 인식 시스템)

  • Son, Chang-Woo;Lee, Seung-Heui;Lee, Min-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.8
    • /
    • pp.767-773
    • /
    • 2008
  • This paper presents a localization system based on the use of electric compass and tracking IR light source. Digital RGB(Red, Green, Blue)signal of digital CMOS Camera is sent to CPLD which converts the color image to binary image at 30 frames per second. CMOS camera has IR filter and UV filter in front of CMOS cell. The filters cut off above 720nm light source. Binary output data of CPLD is sent to DSP that rapidly tracks the IR light source by moving Camera tilt DC motor. At a robot toward north, electric compass signals and IR light source angles which are used for calculating the data of the location system. Because geomagnetic field is linear in local position, this location system is possible. Finally, it is shown that position error is within ${\pm}1.3cm$ in this system.

The analysis of the Effect the Minute Quantities of Infrared Rays that Were not Filtered by IR Cut-Off Filter has on Digital Images (IR Cut-Off Filter가 차단하지 못한 미량의 적외선이 디지털화상에 미치는 영향 분석)

  • Lee, Yong-Hwan;Park, Se-Won;Hong, Jung-Eui
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.205-215
    • /
    • 2011
  • Films are sensitive to ultraviolet rays and in contrast, digital camera sensors are extremely sensitive to infrared rays due to the differences in spectral characteristics. As a result, all digital cameras that use CCD or CMOS are equipped with IR Cut-Off Filter on the overall sensor. Complete block out of infrared rays is ideal, but the actual experiment results showed that infrared rays were not being blocked out completely. Infrared permeability was also different for each camera. Therefore, this study aims to analyze the effect of the minute quantities of infrared rays, which get transmitted due to mechanical properties of IR Cut-Off Filters that are installed on digital cameras, on digital picture images. The results obtained by carrying out a comparative analysis of a UV Filter (infrared transmitting state) and a UV-IR Filter (infrared blocked out state) are as follows. It was confirmed that the minute quantities of infrared rays do affect dynamic range and resolution to some extent, despite the little or no difference in noise and color reproduction.

Fabrication of waveguide using UV Ar-ion laser direct writing (Laser Direct Writing 방법을 이용한 광도파로 제작)

  • Kang H. S.;Suh J.;Lee J. H.;Kim J. O.
    • Laser Solutions
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 2005
  • The laser direct writing method using a UV Argon-ion laser is studied for fabrication of waveguide. The laser direct writing system is constructed with a vision camera, a xy-stage, a motion controller and the delivery components of a laser beam. The UV Argon-ion laser has wavelength range of $333.6\~363.8$ nm. A photo-active UV curable polymer for a planar light-wave circuit(PLC) of single mode is used. This polymer is irradiated by Argon-ion laser and developed by a solvent after a post-baking. The optimum laser direct writing condition is obtained experimentally by changing various process parameters such as laser power, writing speed and focal length. The propagation and coupling loss of a optical waveguide was measured as 1dB/cm and 0.6dB/cm, respectively. Also, the minimum width of waveguide of $100{\mu}m$(ZPLW-207) is obtained. Finally, the waveguides of line, bend and branch type are successfully fabricated.

  • PDF

Investigation on the $8{\times}8$ ReadOut IC for Ultra Violet Detector (UV 검출기 제작을 위한 $8{\times}8$ ReadOut IC에 관한 연구)

  • Kim, Joo-Yeon;Kim, Tae-Geun
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.45-50
    • /
    • 2005
  • A UV camera is being used in various application regions such as industry, medical science, military, and environment monitoring. A ROIC(ReadOut IC) is developed and can read the responses from UV photodiode sensors which are made with III-V nitride semiconductors of GaN series haying high resolution and high efficiency. To design FPA(Focal Plane Array) UV $8{\times}8$ ROIC, the photodiode type sensor devices are modeled as the capacitor type ones. The ROIC reads out signals from the detector at)d outputs sequentially pixel signals after amplifying and noise filtering of them. The ROIC is fabricated using the $0.5{\mu}m$ 2Poly 3Metal N-well CMOS process. And then, it and photodiode array are hybrid bonded by gold stud bumping process using ACP(Anisotropic Conductive Paste). After the packaging, UV images appearing on PC verified the operations of the ROIC.

The Study of Cable Fault Case and the Fault Management System of Electrical Facilities for private use (자외선 영상 이미지 비교를 통한 22.9kV 특고압 설비의 상태진단 연구)

  • Kim, Young-Seok;Shong, Kil-Mok
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.211-213
    • /
    • 2009
  • This paper was studied about the ultra-violet rays(UV) image area and discharge quantity of 22.9kV class polymer insulator using UV camera. The UV image area was begun to observe to 60kV that is about 40% of breakdown voltage of polymer insulator and the area was increased by applied voltage. Also, the discharge quantity was increased at 60kV sharply. If the intensity of breakdown passes over about 40% we can know that need the check on the electrical facility.

  • PDF

Characteristics of a Corona between a Wiring Clamp(Dead End Clamp) and a Porcelain Insulator Used in a 154[kV] Power Receptacle

  • Han, Un-Ki;Kim, Jong-Min;Bang, Sun-Bae;Kim, Han-Sang;Choi, Hyeong-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.57-63
    • /
    • 2007
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154[kV] dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in 154[kV] power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method(FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

Development of Microlens Array for Maskless Lithography Application (Maskless lithography 응용을 위한 마이크로렌즈 어레이 개발)

  • Nam, Min-Woo;Oh, Hae-Kwan;Kim, Geun-Young;Seo, Hyun-Woo;Wei, Chang-Hyun;Song, Yo-Tak;Yang, Sang-Sik;Lee, Kee-Keun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.4
    • /
    • pp.33-39
    • /
    • 2009
  • A microlens array (MLA) was developed based on the wet-etched quartz substrate and coating of UV adhesive on the substrate for maskless lithography application. The developed MLA has the focal length of ${\sim}45\;{\mu}m$ and the spot size of ${\sim}1\;{\mu}m$. The spot size of the focused beam passing through the MLA was detected by CCD camera, and its intensity was monitored by beam profiler. Uniform spots with nearly identical intensities were observed on the focal plane when a beam passes through the fabricated MLA. The focal length was varied depending on thickness of the coated UV adhesive. The thicker the thickness of the UV adhesive was, the shorter the focal length of the MLA was. With a general mask aligner, UV beam focusing was tested onto photoresist (PR). The beams were well focused onto PR when UV passes through the MLA. Depending on the variable distances from the MLA, beam sizes onto PR were controlled. Even at high temperature for a long time, the performances of the MLA were not changed.

  • PDF