• Title/Summary/Keyword: UV$^{254}$

Search Result 310, Processing Time 0.023 seconds

Inactivation of Sewage Microorganisms using Multi-Plasma Process (멀티 플라즈마 공정을 이용한 하수 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.985-993
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor, a multi-plasma reactor was investigated for the inactivation of microorganisms in sewage. We also considered the possibility of degradation of non-biodegradable matter ($UV_{254}$) and total organic carbon (TOC) in sewage. The multi-plasma reactor in this study was divided into high voltage neon transformers, gas supply unit and three plasma modules (consist of discharge, ground electrode and quartz dielectric tube). The experimental results showed that the inactivation of microorganisms with treated water type ranked in the following order: distilled water > synthetic sewage effluent >> real sewage effluent. The dissolved various components in the real sewage effluent highly influenced the performance of the inactivation of microorganisms. After continuous plasma treatment for 10 min at 180 V, residual microorganisms appeared below 2 log and $UV_{254}$ absorbance (showing a non-biodegradable substance in water) and TOC removal rate were 27.5% and 8.5%, respectively. Therefore, when the sewage effluent is treated with plasma, it can be expected the inactivation of microorganisms and additional improvement of water quality. It was observed that the $NH_4{^+}$-N and $PO{_4}^{3-}$-P concentrations of sewage was kept at the constant plasma discharging for 30 min. On the other hand, $NO_3{^-}$-N concentration was increased with proceeding of the plasma discharge.

Degradation of Humic Acid in Ozone/GAC Process (오존/GAC 공정에서의 부식산 분해 특성)

  • Rhee, Dong Seok
    • Journal of Industrial Technology
    • /
    • v.28 no.B
    • /
    • pp.47-52
    • /
    • 2008
  • In this study, GAC adsorption, ozonation and $O_3/GAC$ hybrid processes were investigated for treatment of humic acid. The degradation characteristics and efficiencies of humic acid in each process were evaluated through pH variation, $UV_{254}$ decrease, DOC removal, change of molecular size distribution and by-products formation. DOC removal rate in $O_3/GAC$ hybrid process (80%) was higher than arithmetic sum of ozonation (38%) and GAC adsorption process (19%) by synergism. $UV_{254}$ decrease rate of humic acid was also the highest than any other processes when treated in $O_3/GAC$ hybrid process. Molecular size distribution was not significantly changed in the GAC adsorption process. Main distribution of molecular size of humic acid was converted from 3 k~30 kDa into 0.5 k~3 kDa in ozonation. But the most of large molecular sizes of humic acid converted into small molecules(smaller than 0.5 kDa) in $O_3/GAC$ hybrid process. Quantities of formaldehyde and glyoxal formed in $O_3/GAC$ hybrid process were less than the ones in ozonation.

  • PDF

Phenol Treatment Plasma Reactor of Dielectric Barrier Discharge (유전체 장벽 방전 플라즈마 반응기를 이용한 페놀 처리)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.4
    • /
    • pp.479-488
    • /
    • 2012
  • A Dielectric barrier discharge (DBD) plasma is shown in the present investigation to be effective of phenol degradation in the aqueous solutions in batch reactor with continuous air bubbling. Removal of phenol and effects of various parameters on the removal efficiency in the aqueous solution with high-voltage streamer discharge plasma are studied. The effect of 1st voltage (80 ~ 220 V), air flow rate (3 ~ 7 L/min), pH (3 ~ 11), electric conductivity of solution (4.16 ${\mu}S$/cm, deionized water) ~ 16.57 mS/cm (addition of NaCl 10 g/L) and initial phenol concentration (2.5 ~ 20.0 mg/L) were investigated. The observed results showed that phenol degradation was higher in the basic solution than that of the acidic. The optimum values on the 1st voltage and air flow rate for phenol degradation were 140 V and 6 L/min, respectively. It was considered that absorbance variation of $UV_{254}$ of phenol solution can be use as an indirect indicator of change of the non-biodegradable organic compounds within the treated phenol solution. Electric conductivity was not influenced the phenol degradation. To obtain the removal efficiency of phenol and COD of phenol over 97 % (initial phenol concentration, 10.0 mg/L), 80 min and 120 min were need, respectively. Phenol and COD degradation showed a pseudo-first order kinetics.

Decomposition of Organic Matters by Ozonation in Advanced Water Treatment Process (고도정수처리공정에서 오존의 유기물 분해능)

  • Yoon Taekyung;Lee Gangchoon;Noh Byeongjil
    • Journal of Environmental Science International
    • /
    • v.14 no.3
    • /
    • pp.327-333
    • /
    • 2005
  • The performance of ozone contactor in ozone-BAC advanced water treatment process was evaluated by the degree of decomposition of organic matters. The degree was measured by the analyses of $UV_{254}$ absorbance and the concentrations of DOC and BDOC for the sand filtered water and the ozone treated water, respectively. In addition, the ozone concentration in the contactor, required for the maximum BDOC concentration, was selected as the optimum concentration, and the appropriate residential time of ozone treated water in a reservoir was recommended based on the residual ozone concentration in the treated water. The following results were obtained from the pilot scale experiments. By ozonation $UV_{254}$ absorbance was decreased, and BDOC concentration was increased. The change of DOC concentration by ozonation was negligible, but the excess input of ozone resulted in the removal of the small amount of BDOC by complete oxidation. The optimum ozone concentration was 0.58mg $O_3/mg$ DOC. In order to remove residual ozone, 20minutes of the residential time were enough after ozonation.

Efficiency Evaluation of Different Processes in Drinking Water Treatment (정수처리에서 서로 다른 공정의 처리효율에 대한 비교분석연구)

  • Kim, Hyung-Suk;Lee, Byoung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.597-604
    • /
    • 2011
  • This study was performed to compare finished water quality among three different processes. A detailed assessment of performance was carried out during the five months of operation. Finished water quality was evaluated on the basis of parameters such as Dissolved organic carbon (DOC), $UV_{254}$ absorbance, haloacetic acid formation potential (HAAFP), geosmin, 2-methylisoborneol (2-MIB), heterotrophic bacteria and total coliform bacteria. The treatment processes were Process 1 (coagulation-flocculation-sedimentation-sand filtration-ozone-GAC), Process 2 (coagulation-flocculation-sedimentation -microfiltration-ozone-GAC), and Process 3 (coagulation-flocculation-sedimentation- sand filtration-GAC), compared side by side in the pilot testing. Process 2 was found to have better removal efficiency of DOC, $UV_{254}$ absorbance, HAAFP and heterotrophic bacteria in comparison with process 1 and process 3 under identical conditions. Geosmin, 2-MIB and total coliform bacteria were not detected in finished water from each process.

Determination of Photodegradation Rate Constant of LDPE (LDPE 광분해 반응의 속도 상수 결정)

  • Kim, Hyoun Joo;Jung, Il Hyun;Hong, In Kwon;Lee, Jae Dong
    • Applied Chemistry for Engineering
    • /
    • v.5 no.4
    • /
    • pp.637-645
    • /
    • 1994
  • The LDPE films were photolyzed for 100 hours in UV apparatus with 400-W medium pressure mercury lamp radiating wavelengths longer than 254nm. A simple kinetic model was introduced and was applied to interpret the FT-IR absorbance of carbonyl and hydroperoxide bonds as a function of UV exposure time. From these data, the reaction mechanism and the rate determining step of photodegradation were determined.

  • PDF

Removal of NOM in a Coagulation Process Enhanced by Modified Clay (개질 Clay를 첨가한 응집공정에서의 자연유기물 제거)

  • Park, Ji-Hye;Lee, Sang-Yoon;Park, Hung-Suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.37-46
    • /
    • 2007
  • A feasibility test was conducted to evaluate the addition of turbidity substance in a coagulation process to remove natural organic matters (NOM), the precursor of disinfection by-products (DBPs). The experimental water sources were synthetic water containing 5 mg/L of humic acid and 50 mg/L of NaHCO3 and drinking water resource of Ulsan city (S Dam water, D Dam water and Nak-Dong raw water). The examined turbidity substances were kaolin, acid clay, and modified clay (0.38 meq $NH_4{^+}-N/g$ clay). In Jar tests at different concentrations of the turbidity substances (5, 10, 15, 20, 30 mg/L) using the synthetic water, the turbidity substances improved the removal of turbidity, UV-254 absorbance and dissolved organic carbon (DOC) by 23.8-38.1%, 17.0-24.5% and 2.5-44.5%, respectively. The modified clay showed higher removal efficiencies than other substances. In Jar tests using the drinking water, 10 and 20 mg/L of modified clay enhanced the removal efficiencies of turbidity, UV-254 absorbance, DOC, trihalomethane formation potential (THMFP), and haloacetic acid formation potential (HAAFP) by 3.0~4.3%, 19.1~29.0%, 12~34.9%, 4.9~36.7%, and 1.6~30.2%, respectively.

A Study on the Biodegradability and Characteristics Based on Apparent Molecular Weight Distribution of Dissolved Organic Matter in Sewage (하수중 용존 유기물의 생분해도 및 분자량 분포에 따른 거동특성에 관한연구)

  • 최정헌;이윤진;명복태;우달식;이운기;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.92-99
    • /
    • 2001
  • This present study was aimed to investigate the characteristics of dissoloved organic matter (DOC) in sewage. The results are summarized as follows ; The plateaux reached in 3~4 days by the biodegradability test on sewage samples based on DOC. 쏭 rations of BDOC to DOC were 48, 21, 13 and 11% for raw sewage, primary treatment effluent, secondary treatment effluent and final treatment effluent, respectively. As the SUVA values ranged less 3L/m.mg for the effluent of sewage treatment plant, the DOC is composed largely of non-humic materials, hydrophilic, less aromatic as compared to waters with higher SUVA values. Through the biodegradability test, Dissolved organics showed that the quantity of LMW(Low Molecular Weight) less than 1,000 daltons was decreased, HMW(High Molecular Weight) more than 30,000 daltons had a tendency to increase. Large portion of UV$^{254}$ in final treatment effluent was increased of MMW(Medium Molecular Weight). Also, average removal efficiency of DOC was 32% during sewage treatment.

  • PDF

An aluminum-based reflective nanolens array that enhances the effectiveness of a continuous-flow ultraviolet disinfection system for livestock water

  • Changhoon Chai;Jinhyung Park
    • Journal of Animal Science and Technology
    • /
    • v.65 no.1
    • /
    • pp.258-270
    • /
    • 2023
  • Climate change has worsened droughts and floods, and created conditions more likely to lead to pathogen contamination of surface water and groundwater. Thus, there is a growing need to disinfect livestock water. Ultraviolet (UV) irradiation is widely accepted as an appropriate method for disinfecting livestock water, as it does not produce hazardous chemical compounds and kills pathogens. However, UV-based disinfection inevitably consumes electricity, so it is necessary to improve UV disinfection effectiveness. Aluminum-based reflective nanolens arrays that enhanced the effectiveness of a continuous-flow UV water disinfection system were developed using electrochemical and chemical processes, including electropolishing and two-step anodization. A continuous UV disinfection system was custom designed and the parts were produced using a three-dimensional printer. Electropolished aluminum was anodized at 40 and 80 V in 0.3 M oxalic acid, at 120 and 160 V in 1.0 M phosphoric acid, and at 200 and 240 V in 1.5 M citric acid. The average nanolens diameters (D) of the aluminum-based reflective nanolens arrays prepared using 40, 80, 120, 160, 200, and 240 V anodization were 95.44, 160.98, 226.64, 309.90, 296.32, and 339.68 nm, respectively. Simple UV reflection behind irradiated water disinfected Escherichia coli O157:H7 in water more than did the non-reflective control. UV reflection and focusing behind irradiated water using an aluminum-based reflective nanolens array disinfected E. coli O157:H7 more than did simple UV reflection. Such enhancement of the UV disinfection effectiveness was significantly effective when a nanolens array with D 226.64 nm, close to the wavelength of the irradiated UV (254 nm), was used.

Preparation of the Polymers Containing Phenylamide and Dimethylaminoethyl Groups and their Properties as a Nagative Photoresist

  • Chae, Kyu-Ho;Kang, Jin-Koo;Kim, Su-Kyung;Chough, Sung-Hyo
    • Journal of Photoscience
    • /
    • v.7 no.2
    • /
    • pp.47-52
    • /
    • 2000
  • The copolymmers of N, N-dimethylaminoethyl methacrylate(DAEM) and N-arylmethacrylamide (AMA) were prepared, and their photochemical properties as a negative photoresist were studied by the measurements of insoluble fraction, and by UV and IR absorption spectral changes. These copolymers are soluble in DMF, actone, methanol, of acidic buffer solutions. Solubility of these copolymer films in the vuffer solutions increased with the amount of DAEM units in the copolymer and decreased with the pH value. The insoluble fraction of the copolymer films in the buffer solution of pH 4 of in methanol increased with irradiation time and the amount of AMA units in the copolymer. UV and IR spectral changes indicated that not only photo-crosslinking but also the photo-Fries rearrangement took place upon irradiation with a 254nm UV light.

  • PDF