• Title/Summary/Keyword: UT-A

Search Result 389, Processing Time 0.019 seconds

Expression of UT-A in Rat Kidney: Ultrastructural Immunocytochemistry (흰쥐 콩팥에서 요소운반체-A의 발현: 미세구조적 면역세포화학법)

  • Lim, Sun-Woo;Jung, Ju-Young;Kim, Wan-Young;Han, Ki-Hwan;Cha, Jung-Ho;Chung, Jin-Woong;Kim, Jin
    • Applied Microscopy
    • /
    • v.32 no.2
    • /
    • pp.91-105
    • /
    • 2002
  • Urea transport in the kidney is mediated by a family of transporter proteins that includes renal urea transporters (UT-A) and erythrocyte urea transporters (UT-B). The cDNA of five isoforms of rat UT-A, UTA1, UT-A2, UT-A3, UT-A4, and UT-A5 have been cloned. The purpose of this study was to examine the expression of UT-A (L194), which marked UT-A1, UT-A2 and UT-A4. Male Sprague-Dawley rats, weighing approximately 200 g, were divided into three group: control rats had free access to water, dehydrated rats were deprived of water for 3 d, and water loaded rats had free access to 3% sucrose water for 3 d before being killed. The kidneys were preserved by in vivo perfusion through the abdominal aorta with the 2% paraformaldehyde-lysine- periodate (PLP) or 8% paraformaldehyde solution for 10 min. The sections were processed for immunohistochemical studies using pre-embedding immunoperoxidase method and immunogold method. In the normal rat kidney, UT-A1 was expressed intensely in the cytoplasm of the inner medullary collecting duct (IMCD) cell and UT-A2 was expressed on the plasma membrane of the terminal portion of the shortloop descending thin limb (DTL) cells (type I epithelium) and of the long-loop DTL cells (type II epithelium) in the initial part of the inner medulla. Immunoreactivity for UT-A1 in the IMCD cells, was decreased in dehydrated animals whereas strongly increased in water loaded animals compared with control animals. In the short-loop DTL, immunoreactivity for UT-A2 was increased in intensity in both dehydrated and water loaded groups. However, in the long-loop DTL of the outer part of the inner medulla, immunoreactivity for UT-A2 was markedly increase in intensity in dehydrated group, but not in water loaded group. In conclusion, in the rat kidney, UT-A1 is located in the cytoplasm of IMCD cells, whereas UT-A2 is located in the plasma membrane of both the short-and long-loop DTL cells. Immunohistochemistry studies revealed that UT-A1 and UT-A2 may have a different role in urea transport and are regulated by different mechanisms.

Clinical and pharmacological application of multiscale multiphysics heart simulator, UT-Heart

  • Okada, Jun-ichi;Washio, Takumi;Sugiura, Seiryo;Hisada, Toshiaki
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.23 no.5
    • /
    • pp.295-303
    • /
    • 2019
  • A heart simulator, UT-Heart, is a finite element model of the human heart that can reproduce all the fundamental activities of the working heart, including propagation of excitation, contraction, and relaxation and generation of blood pressure and blood flow, based on the molecular aspects of the cardiac electrophysiology and excitation-contraction coupling. In this paper, we present a brief review of the practical use of UT-Heart. As an example, we focus on its application for predicting the effect of cardiac resynchronization therapy (CRT) and evaluating the proarrhythmic risk of drugs. Patient-specific, multiscale heart simulation successfully predicted the response to CRT by reproducing the complex pathophysiology of the heart. A proarrhythmic risk assessment system combining in vitro channel assays and in silico simulation of cardiac electrophysiology using UT-Heart successfully predicted drug-induced arrhythmogenic risk. The assessment system was found to be reliable and efficient. We also developed a comprehensive hazard map on the various combinations of ion channel inhibitors. This in silico electrocardiogram database (now freely available at http://ut-heart.com/) can facilitate proarrhythmic risk assessment without the need to perform computationally expensive heart simulation. Based on these results, we conclude that the heart simulator, UT-Heart, could be a useful tool in clinical medicine and drug discovery.

Effects of Reciprocal Inhibition Using Thera-band on Scapular Muscle Activities During Arm-lifting Exercises in Subjects with Rounded Shoulder Posture

  • Lee, Chi-Hun;Cynn, Heon-Seock;Shin, A-Reum;Lee, Ji-Hyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.3
    • /
    • pp.11-20
    • /
    • 2020
  • PURPOSE: Excessive activity of the upper trapezius (UT) muscle contributes to a rounded shoulder posture (RSP) through abnormal rotation of the scapula that weakens the lower trapezius (LT) and serratus anterior (SA) muscles. This study compared the effects of two arm-lifting exercises with and without the use of a Thera-band on the activities of LT, SA, and UT muscles, and the LT/UT and SA/UT activity ratio in subjects with a rounded shoulder posture. METHODS: Sixteen subjects with RSP participated in this study. All subjects performed arm-lifting (AL), diagonal arm-lifting (DAL), arm lifting with isometric adduction (ALIA), and diagonal arm-lifting with isometric adduction (DALIA) exercises. The surface electromyography data, LT, SA, UT, and the LT/UT and SA/UT activity ratios were measured. A paired t-test was used to compare the differences between two arm-lifting exercises and two arm lifting with isometric adduction exercises. RESULTS: In ALIA and DALIA exercises, the UT muscle activity decreased significantly, whereas the LT/UT, SA/UT activity ratio increased significantly. The activity of SA muscle increased significantly more with DALIA than that with DAL. CONCLUSION: Arm-lifting exercises using a Thera-band can be implemented as an effective way to reduce the UT overactivity and increase the SA activity and LT/UT, SA/UT activity ratio in subjects with RSP.

A study on a UT applied forecast prototype and policy for u-Gov's actional system to disaster (u-Gov의 재난 대응체계를 위해 UT를 응용한 예측 프로토타입과 정책적과제 연구)

  • Jeong, Young-Chul;Bae, Yong-Guen
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.10
    • /
    • pp.173-182
    • /
    • 2010
  • Recently, the society confronts unpredictable disasters and the aspects varies in diverse ways. As a pessimistic perception on the social safety starts emerging, the UT utilized actional system for disaster is viewed as a solution. Therefore, in this paper, I provided UT applied forecast prototype which is a portion of u-Gov's application services. Also, as one of UT applied policy subject, I distinguished and analyzed the differences between e-Gov and u-Gov and, finally, suggested u-Gov's reform in order to surpass e-Gov's limitation and amelioration for possible problems during prototype materialization.

Reliability Analysis of UT Measurement for Evaluating Pipe Wall Thinning in Nuclear Power Plants (배관감육 평가를 위한 UT 측정 신뢰도 분석)

  • Yun, Hun;Hwang, Kyeong-mo
    • Corrosion Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.129-134
    • /
    • 2012
  • UT(Ultrasonic Test), one of the non-destructive tests, is the most common thickness measurement method for evaluating the wear rate in NPPs(Nuclear Power Plants). UT is used widely because it is easy and safe for use. However some amount of error inevitably occurs in attempting to measure the thickness. The error, that could make the thickness data thicker or thinner, may affect estimation of wear rate in pipes. NPPs are composed of a lot of pipes and components. Some of them are tested to check the current status during RFO(Re-Fueling Outage). Reliability analysis of UT is essential for evaluating pipe wear rate and establishing the long-term management plan in NPPs. This paper reviewed the cause of error occurrence and presented the UT data reliability analysis method. Also, this paper shows the application result of reliability analysis to the UT data acquired in NPPs.

Comparison of Muscle Activity Ratio of Upper Trapezius to Serratus Anterior During Shoulder Elevation Between Subjects With and Without Pain Experienced in Upper Trapezius

  • Ahn, Sun-Hee;Kwon, Oh-Yun;Choung, Sung-Dae;Kim, Si-Hyun;Jeon, In-Cheol
    • Physical Therapy Korea
    • /
    • v.21 no.2
    • /
    • pp.67-73
    • /
    • 2014
  • The aim of this study was to compare the activity of the upper trapezius (UT) and serratus anterior (SA) and ratio of UT to SA during shoulder elevations. Ten subjects with UT pain (UTP) and 13 subjects without UTP participated in this study. Subjects with a UTP of over five in a pain intensity visual analogue scale (0-10 ㎝) for more than 2 months and latent myofascial trigger points (MTrPs) in the UT muscle were included in the UTP group. Electromyography (EMG) data of UT and SA at 1st and 10th elevations were analyzed. Two-way repeated analyses of variance were used to compare the EMG activity of UT and SA and the ratio of UT to SA during shoulder elevations between groups with and without UTP. There was a significant increase in UT/SA ratio in the group with UTP compared to the group without UTP (p=.01). The activity of UT and SA measured at the 10th elevation was significantly greater than that in the first elevation (p<.05). The activity of SA was significantly greater in the group without UTP than the group with UTP (p=.03). However, there was no significant difference between groups with and without UTP in terms of UT activity (p=.28). These results indicate that UTP may have relevance to the increased muscle activity ratio of UT to SA during shoulder elevations.

Introduction and Feasibility on a New Technology for the Pipe Wall Thinning Evaluation of Nuclear Power Plants (원전 배관감육 평가를 위한 새로운 기법의 도입 및 타당성)

  • Hwang, Kyeong Mo;Yun, Hun;Park, Hyun Cheol
    • Corrosion Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.62-69
    • /
    • 2014
  • A huge number of carbon steel piping components installed in the secondary system of nuclear power plants are exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), Cavitation, Flashing, and LDIE (Liquid Droplet Impingement Erosion). Those aging mechanisms can lead to thinning of the piping components. To manage the wall thinning degradation, most of utilities in the world predict the wall thinning rate based on the computational program such as CHECWORKS, COMSY, and BRT-CICERO, evaluate the UT (Ultrasonic Test) data, and determine next inspection timing, repair or replacement, if needed. There are several evaluation methods, such as band, blanket, and strip methods, commonly used for determining the wear of piping components from single UT inspection data. It has been identified that those single UT evaluation methods not only do not consider the manufacturing features of pipes, but also may exclude the data of the most thinned point when determining the representative wear rate of piping components. This paper describes a newly developed single UT evaluation method, E-Cross method, for solving above problems and introduces application examples for several pipes and elbows. It was identified that the E-Cross method using the length and width of UT data excluded the most thinned points appropriate as the single UT evaluation method for thinned piping components.

Does the Use of Sling Influence Scapular Stabilizers' Activity During Push Up Plus Exercises in Subjects With Scapular Dyskinesis?

  • Lee, Dong-hun;Cynn, Heon-seock;Yoon, Tae-lim;Lee, Ji-hyun
    • Physical Therapy Korea
    • /
    • v.24 no.1
    • /
    • pp.86-96
    • /
    • 2017
  • Background: Scapular dyskinesis is characterized by altered scapular position and motion. Specifically, excess activation of the Upper trapezius (UT) combined with decreased Lower trapezius (LT) and Serratus anterior (SA) have been observed. The Standard push-up plus exercise (SPP) is considered as a therapeutic exercise for increasing SA activity and maintaining the scapular kinematics. In addition, Using the Sling surface can lead to higher muscle activity. However, the advantage of an unstable surface has been uncertatin. Objects: To compare the activation of the UT, LT, and lower serratus anterior (LSA) muscles during various push-up plus exercises with and without sling in subjects with scapular dyskinesis. Methods: Total 18 male subjects with scapular dyskinesis were recruited. The UT, LT, and LSA electromyographic activities and the UT/LSA and UT/LT EMG activity ratios were measured during three push-up plus exercises with and without sling. Two-way repeated of analysis of variance was used to determine the statistical significance. Results: The UT activity was significantly lower in all postures without sling than that with sling. In addition, the LSA activity was significantly greater without than with sling, and significantly large in SPP, Low back supported push-up plus (LSPP), and Quadruped push-up plus. Additionally, the UT/LSA and UT/LT activity ratios were lower in SPP and LSPP without sling than with the other four push-up plus exercises. Conclusion: The push-up plus without sling were considered to decrease UT and increase LSA activity compared with exercises with sling. Furthermore, SPP without sling seems to be a more effective exercise for increasing LSA activity and lowering the UT/LSA and UT/LT activity ratios in scapular dyskinesis subjects.

Selective Muscle Activation With Visual Electromyographic Biofeedback During Scapular Posterior Tilt Exercise in Subjects With Round-Shoulder Posture

  • Son, Jae-ik;Lim, One-bin;Han, Hae-rim;Cynn, Heon-seock;Yi, Chung-hwi
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.17-26
    • /
    • 2015
  • The purpose of this study was to investigate the effects of visual electromyography (EMG) biofeedback on the EMG activity of the lower trapezius (LT), serratus anterior (SA), and upper trapezius (UT) muscles, the LT/UT and SA/UT EMG activity ratios, and the scapular upward rotation angle during scapular posterior tilting exercise (SPTE). Twenty-four subjects with round-shoulder posture participated in this study. The EMG activities of the LT, SA, and UT were collected during SPTE both without and with visual EMG biofeedback. The scapular upward rotation angle was measured at the baseline, after SPTE without visual EMG biofeedback, and after SPTE with visual EMG biofeedback. The LT, SA, and UT EMG activities, and the LT/UT and SA/UT EMG activity ratios were analyzed by paired t-test. The scapular upward rotation angle was statistically analyzed using one-way repeated analysis of variance. If a significant difference was found, a Bonferroni correction was performed (p=.05/3=.017). The EMG activities of LT and SA significantly increased, and the EMG activity of UT significantly decreased during SPTE with visual EMG biofeedback compared to SPTE without visual EMG biofeedback (p<.05). In addition, the LT/UT and SA/UT EMG activity ratios significantly increased during SPTE with visual EMG biofeedback compared to SPTE without visual EMG biofeedback (p<.05). Significant increases were found in the scapular upward rotation angle after SPTE without and with visual EMG biofeedback compared to baseline (p<.017), and no significant differences were observed in the scapular upward rotation angle between SPTE without and with visual EMG biofeedback. In conclusion, SPTE using visual EMG biofeedback may be an effective method for increasing LT and SA activities while reducing UT activity.

Two-Dimensional Numerical Modeling and Simulation of Ultrasonic Testing

  • Yim, Hyun-June;Baek, Eun-Sol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.649-658
    • /
    • 2002
  • As an attempt to further improve the reliability and effectiveness of ultrasonic testing (UT), a two-dimensional numerical simulator of UT was developed. The simulator models the wave medium (or test object) using the mass-spring lattice model (MSLM) that consists of mass-points and springs. Some previous simulation results, obtained by using MSLM, are briefly reviewed in this paper, for propagation, reflection, and scattering of ultrasonic waves. Next, the models of transmitting and receiving piezoelectric transducers are introduced with some numerical results, which is a main focus of this paper. The UT simulator, established by combining the transducer models with the MSLM, was used to simulate many UT setups. In this paper, two simple setups are considered as examples, and their simulated A-scan signals are discussed. The potential of the MSLM, transducer models, and the UT simulator developed in this study to be used in the actual UT is confirmed.