• Title/Summary/Keyword: UT

Search Result 479, Processing Time 0.024 seconds

Feasibility Study of Flexible Phased Array Ultrasonic Technology Using Irregular Surface Specimen (불규칙 표면 시편을 이용한 Flexible 위상배열초음파기술 적용 연구)

  • Lee, Seung-Pyo;Moon, Yong-Sig;Jung, Nam-Du
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.52-60
    • /
    • 2015
  • Nuclear power plant contain many dissimilar metal welds that connect carbon steel components with stainless steel pipes using alloy600 welding materials. Primary water stress corrosion cracks at dissimilar metal welds have been continuously reported around the world. In periodic integrity evaluations, dissimilar metal welds are examined using a generic ultrasonic testing procedure, KPD-UT-10. In this procedure, the gap between the probe and examination surface is limited to 1/32 inch (0.8mm). It is not easy to test some dissimilar metal welds in Korean plants applying ordinary technology because of their tapered shapes and irregular surface conditions. This paper introduces a method for applying a flexible phased array technology to improve the reliability of ultrasonic testing results for various shapes and surface conditions. The artificial flaws in specimens with irregular surfaces were completely detected using the flexible phased array ultrasonic technology. Therefore, it can be said that the technology is applicable to field examination.

Activity of Muscles Surrounding Shoulder Joint during Push-Up Exercise according to the Change of Tilting Table Angle

  • Cho, Yong-Ho;Choi, Jin-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.3
    • /
    • pp.49-54
    • /
    • 2016
  • PURPOSE: This study was implemented to measure the muscle activity of muscles surrounding shoulder during push-up exercise according to the slope angle. METHODS: This study has research subject consisting of 25 normal male adults without neurologic or musculoskeletal injury in shoulder part. EMG was used as a tool for measuring muscle activity and four muscles including upper trapezius (UT), middle trapezius (MT), Lower Trapezius (LT), and Serratus Anterior (SA) were chosen for measuring the muscle activity of muscles surrounding shoulder. Tilting table slope was set at $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ and push-up motion was performed three time for each case to use the average value. The measured value was used after generalization process to create %RVC value where the measured value was standardized by using $0^{\circ}$ as a standard. RESULTS: There was a difference of muscle activity according to the tilting table slope during push-up exercise. In UT, MT, and SA, there was no significant $0^{\circ}$ and $30^{\circ}$, $45^{\circ}$ and $60^{\circ}$. But there was significant $30^{\circ}$ and $45^{\circ}$. LT was significant difference between $45^{\circ}$ and $60^{\circ}$ (p<.05). CONCLUSION: There are cases where push-up exercise should be selectively implemented due to shoulder problems. According to this results between $0^{\circ}$ and $30^{\circ}$, push up will be able to more effectively exercise. Applying proper angle of tilting table for push-up to patients who have difficulties in performing motions along with physical consumption can deliver effective and easy exercise program.

Comparison of the Upper and Lower Trapezius and Serratus Anterior during Push-up Plus Exercise with and without an Elastic Shoulder Band

  • Kim, Kyeong-Jin;Woo, Hye-Jin;Hong, Yu-Jeong;Hwang, Young-In
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.3
    • /
    • pp.75-80
    • /
    • 2018
  • PURPOSE: Scapular stability is very important to arm function during activities of daily living. The push-up plus exercise is commonly used to stabilize the shoulder muscles. In the present study, we designed an elastic shoulder band (ESB) that could be used with the push-up plus exercise and studied muscle activities of the serratus anterior (SA) and the lower and the upper trapezius (LT and UT) on stable and unstable support. METHODS: Fifteen healthy people participated in this study. Three muscles were investigated using surface EMG with and without the ESB on stable and unstable support. All subjects performed each trial three times for 7 seconds per set and rested for 30 seconds. Repeated one-way ANOVA was used for statistical analyses. RESULTS: The EMG activity of the SA was significantly different during the push-up plus exercise on stable support with the ESB compared with that on unstable support without the ESB (p<.05). However, there were no differences in the activities of UT and LT on stable and unstable support (p>.05). CONCLUSION: The ESB was effective for the activity of SA during the push-up plus exercise on stable support; therefore, it has the potential for use by people during push-up plus exercises. However, further studies are required to investigate the rehabilitation tools for patients with shoulder instability.

Polymeric nanoparticles as dual-imaging probes for cancer management

  • Menon, Jyothi U.;Jadeja, Parth;Tambe, Pranjali;Thakore, Dheeraj;Zhang, Shanrong;Takahashi, Masaya;Xie, Zhiwei;Yang, Jian;Nguyen, Kytai T.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.3 no.3
    • /
    • pp.129-140
    • /
    • 2016
  • This article reports the development of biodegradable photoluminescent polymer (BPLP)-based nanoparticles (NPs) incorporating either magnetic nanoparticles (BPLP-MNPs) or gadopentate dimeglumine (BPLP-Gd NPs), for cancer diagnosis and treatment. The aim of the study is to compare these nanoparticles in terms of their surface properties, fluorescence intensities, MR imaging capabilities, and in vitro characteristics to choose the most promising dual-imaging nanoprobe. Results indicate that BPLP-MNPs and BPLP-Gd NPs had a size of $195{\pm}43nm$ and $161{\pm}55nm$, respectively and showed good stability in DI water and 10% serum for 5 days. BPLP-Gd NPs showed similar fluorescence as the original BPLP materials under UV light, whereas BPLP-MNPs showed comparatively less fluorescence. VSM and MRI confirmed that the NPs retained their magnetic properties following encapsulation within BPLP. Further, in vitro studies using HPV-7 immortalized prostate epithelial cells and human dermal fibroblasts (HDFs) showed > 70% cell viability up to $100{\mu}g/ml$ NP concentration. Dose-dependent uptake of both types of NPs by PC3 and LNCaP prostate cancer cells was also observed. Thus, our results indicate that BPLP-Gd NPs would be more appropriate for use as a dual-imaging probe as the contrast agent does not mask the fluorescence of the polymer. Future studies would involve in vivo imaging following administration of BPLP-Gd NPs for biomedical applications including cancer detection.

The Comparison of Triladyl and LEY for Cryosurvival Improvement of Sperm Separated by Percoll in Miniature Pig (Percoll 분리된 미니돼지 정액에서 LEY와 Triladyl을 이용한 동결융해후의 정자 성상 비교)

  • Lee, Sang-Hee;Yoo, Han-Jun;Lee, Yong-Seung;Cheong, Hee-Tae;Yang, Boo-Keun;Kim, Dae-Young;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • v.34 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The objective of this study was to evaluated the efficiency of sperm cryosurvival using each extenders Triladyl and LEY containing egg yolk to the cryopreservation of separated sperm by percoll in miniature pig. The ejaculated semen from miniature pig was separated by 65% percoll and un-separated sperm as a control before freezing. The freezing of diluted semen added with Triladyl containing egg yolk and LEY solution (solution I: 11% Lactose or Triladyl + egg yolk; solution II: solution I + glycerol + OEP). Analysis of sperm ability was estimated by viability, capacitation acrosome reaction using chlortetracycline (CIC) the morphologic abnormality and hypoosmotic swelling test(HOST). The groups were designed that as separated sperm by Percoll with Triladyl(ST) or LEY(SL) for cryopreservation. And unseparated sperm with Triladyl(UT) or LEY(UL). As a results, the viability was higher significantly(p<0.05) in ST, SL, UT than UL extender. The morphologic abnormality was measured significantly (p<0.05) lower in ST than other extenders. The AR-patterned in CTC analysis was measured significantly(p<0.05) lower in SL and UL than other extenders. In conclusion, using Triladyl extender resulted in viability and morphology of separated sperm by percoll that were effective than using LEY extender, but it resulted in capacitation acrosome reaction was lower than using LEY extender.

Comparative Effect of Modified Shrug Exercises With and Without Trunk Stabilization Exercise on Scapular Upward Rotator EMG and Thickness in Subjects With Scapular Downward Rotation Syndrome

  • Kim, Ji-hyun;Yoon, Hyeo-bin;Park, Joo-hee;Jeon, Hye-seon
    • Physical Therapy Korea
    • /
    • v.24 no.4
    • /
    • pp.60-67
    • /
    • 2017
  • Background: Scapular downward rotation syndrome (SDRS) is a common scapular alignment impairment that causes insufficient upward rotation and muscle imbalance, shortened levator scapulae (LS) and rhomboid, and lengthened serratus anterior (SA) and trapezius. A modified shrug exercise (MSE), performing a shrug exercise with the shoulders at $150^{\circ}$ abduction, is known as an effective exercise to increase scapular stabilizer muscle activation. Previous studies revealed that scapular exercise are more effective when combined with trunk stabilization exercises in decreasing scapular winging and increasing scapular stabilizer muscle activation. Objects: The purpose of our study was to clarify the effect of MSE with or without trunk stabilization exercises in subjects with SDRS. Methods: Eighteen volunteer subjects (male=10, female=8) with SDRS were recruited for this experiment. All subjects performed MSE under 3 different conditions: (1) MSE, (2) MSE with an abdominal draw-in maneuver (ADIM), and (3) MSE with an abdominal expansion maneuver (AEM). The muscle thickness of the lower trapezius (LT) and the SA were measured using an ultrasonography in each condition. Electromyography (EMG) data were collected from the LT, LS, SA, and upper trapezius (UT) muscle activities. Data were statistically analysed using one-way repeated analysis of variance at a significance level of .05. Results: The muscle thickness of the LT and the SA were the significant different in the MSE, MSE with ADIM (MSE+ADIM) and MSE with AEM (MSE+AEM) conditions (p<.05) In both LT and SA, the order of thick muscle thickness was MSE+AEM, MSE+ADIM, and MSE alone. No significant differences were found in the EMG activities of the SA, UT, LS, and LT in all condition. Conclusion: In conclusion, MSE is more beneficial to people with SDRS when combined with trunk stabilization exercises by increased thickness of scapular stabilizer muscles.

A Study on the Nondestructive Test Method for Adhesively Bonded Joint in Motor Case Assembly (연소관 조립체의 접착 체결부에 대한 비파괴 시험 방법 연구)

  • Hwang, Tae-Kyung;Lee, Sang-Ho;Kim, Dong-Ryun;Moon, Soon-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.343-352
    • /
    • 2006
  • In the present paper, the nondestructive test method was suggest to establish the bonding status of a motor case assembly composed of a steel motor case, adiabatic rubber layer and an ablative composite tube with strain data, AE(acoustic emission) signals and UT(ultrasonic test) data. And, finite element analysis was conducted to verify quantitatively the bonding status of motor case assembly under inner pressure loading. The bonding status could be judged whether the bonding status is perfect or contact condition by the data correlation study with AE signals and strain data measured from air pressure test. And, to classify the bonding status of motor case and rubber layer among bonding layers, UT method was also applied. From this study, the bonding status could be classified and detected into fourth types for all bonding layers as follows: (1) initial un-bonding, (2) perfect do-bonding during an air pressure test, (3) partially de-bonding during an air pressure test, and (4) perfect bonding.

The Feedback Mirror Therapy in Stroke Patients Effect of Muscle Activity and Function of the Upper Extremity (거울되먹임 융합 치료가 뇌졸중 환자의 상지 근활성도와 상지 기능에 미치는 영향)

  • Uhm, Yo-Han
    • Journal of Digital Convergence
    • /
    • v.13 no.6
    • /
    • pp.205-212
    • /
    • 2015
  • The purpose of this study was to find out the effect that muscle activity of upper extremity and functional test in the case of the stroke patient by using the feedback mirror therapy. Sixteen subjects were recruited and randomly divided into two groups. one group was trained feedback mirror therapy and other group was action observation training. This process was carried out five times a week for eight weeks. To upper extremity test was used to MFT, FMA and in order to test UT, DM, BB, FCR, ECRL used to muscle activity. After the training, exclude FCR an upper extremity motor function of target showed significant difference between two groups and especially an experimental group showed significant muscle activity and MFT, FMA score improvement of UT, DM, BB, ECRL. Therefore, feedback mirror therapy is more upper extremity motor function and muscle activity improvement effect than action observation training.

A Study of the Influence of Choice of Record Fields on Retrieval Performance in the Bibliographic Database (서지 데이터베이스에서의 레코드 필드 선택이 검색 성능에 미치는 영향에 관한 연구)

  • Heesop Kim
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.35 no.4
    • /
    • pp.97-122
    • /
    • 2001
  • This empirical study investigated the effect of choice of record field(s) upon which to search on retrieval performance for a large operational bibliographic database. The query terms used in the study were identified algorithmically from each target set in four different ways: (1) controlled terms derived from index term frequency weights, (2) uncontrolled terms derived from index term frequency weights. (3) controlled terms derived from inverse document frequency weights, and (4) uncontrolled terms based on universe document frequency weights. Su potable choices of record field were recognised. Using INSPEC terminology, these were the fields: (1) Abstract. (2) 'Anywhere'(i.e., ail fields). (3) Descriptors. (4) Identifiers, (5) 'Subject'(i.e., 'Descriptors' plus Identifiers'). and (6) Title. The study was undertaken in an operational web-based IR environment using the INSPEC bibliographic database. The retrieval performances were evaluated using D measure (bivariate in Recall and Precision). The main findings were that: (1) there exist significant differences in search performance arising from choice of field, using 'mean performance measure' as the criterion statistic; (2) the rankings of field-choices for each of these performance measures is sensitive to the choice of query : and (3) the optimal choice of field for the D-measure is Title.

  • PDF

Fracture Behavior Analysis in CFRP Specimens by Acoustic Emission and Ultrasonic Test (음향방출 및 초음파시험을 이용한 CFRP 시험편의 파괴 거동 해석)

  • Ahn, Seok-Hwan;Nam, Ki-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.251-260
    • /
    • 2001
  • Damage Profess of CFRP laminates under monotonic tensile test was characterized by the correlation between Acoustic Emission(AE) and Ultrasonic Test(UT). The amplitude distribution of AE signal from a specimens is an aid to the determination of the extent of the different fracture mechanism such as matrix crack, debonding, fiber pullout and fiber fracture as load is increased. In addtion, the characteristics of ultrasonic amplitude attenuation are useful lot analysis of the different type of fracture mechanism. Different orientation of carbon fiber reinforced plastic specimens were used to investigate the AE amplitude range and ultrasonic amplitude attenuation. Finally, loading-unloading tests were carried out to check Felicity effect. During the tests, ultrasonic amplitude attenuation was investigated at the same time and compared with AE parameters. The result showed that two parameters of both AE and UT could be effectively used for analysis of fracture mechanism in CFRP laminates.

  • PDF