• Title/Summary/Keyword: UPS(uninterruptible Power Supply)

Search Result 174, Processing Time 0.023 seconds

A Voltage Disturbance Generator for the Performance Test of 1-Phase UPS (단상 무정전 전원공급 장치의 성능시험을 위한 전압변동 발생기)

  • Byeon, Woo-Yeol;Nho, Eui-Cheol;Kim, In-Dong;Choi, Nam-Sup;Joung, Gyu-Bum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.146-151
    • /
    • 2005
  • This paper describes a new voltage disturbance generator for the performance test of a 1-phase UPS(Uninterruptible Power Supply). The proposed scheme has the ability of voltage sag, swell, and outage generation. The structure of the proposed generator is simple and cost-effective. The voltage disturbance can be generated with easy control system. The circuit operation and characteristics of the proposed converter are described and the usefulness of the converter is verified through computer simulations and experimental results.

The Battery Management System for UPS Lead-Acid Battery (UPS용 납축전지를 위한 배터리관리시스템)

  • Seo, Cheol-Sik;Moon, Jong-Hyun;Park, Jae-Wook;Kim, Geum-Soo;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.127-133
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system control the currents and voltages of battery for optimum conditions to estimate the State Of Charge(SOC) in charge or discharge mode. It proved the performance and the algorithm for the estimation of SOC, through the experiments which using the charge and discharge tester and the field tests.

Advanced Synchronous Reference Frame Controller for three-Phase UPS Powering Unbalanced and Nonlinear Loads (3상 무정전 전원장치에 적합한 새로운 구조의 동기좌표계 전압제어기)

  • Hyun Dong-Seok;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.508-517
    • /
    • 2005
  • This paper describes a high performance voltage controller for 3-phase 4-wire UPS (Uninterruptible Power Supply) system, and proposes a new scheme of synchronous reference frame controller in order to compensate for the voltage distortions due to unbalanced and nonlinear loads. Proposed scheme can eliminate the negative sequence voltage component due to unbalanced loads and also reduce the harmonic voltage component due to non-linear loads, even when the bandwidth of voltage control loop is a very low. In order to compensate for the effects of unbalanced loads, the synchronous reference frame controller with the positive and negative sequence computation block is proposed, and the synchronous frame controller with a bandpass filter is proposed to compensate for the selected harmonic frequency of output voltage. The effectiveness of the proposed scheme has been investigated and verified through computer simulations and experiments by a 30kVA UPS.

Development of Online Battery Management System for Uninterruptible Power Supply (무정전 전원공급장치용 온라인 배터리 관리시스템 개발)

  • Nam Jong-ha;Choi Jin-Hong;Kim Seung-Jong;Kim Jae-Woong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.830-833
    • /
    • 2004
  • UPS 시스템에서 정전시 안정적인 전력공급을 방해하는 요소의 대부분은 배터리의 불량이 차지하고 있다. 일반적으로 UPS 시스템에 적용되는 배터리는 일정시간이 경과되면 전체를 교체하는 관리시스템을 가지며, 주기적인 방전시험을 실시하지만 교체기준에 대한 명확한 방안이 마련되어 있지 않다. 일부에서는 배터리의 내부저항 혹은 임피던스를 측정하여 배터리의 교체여부를 판단하는 기준으로 삼고 있지만 배터리의 비선형적 특성으로 인하여 그 오차범위는 크다고 할 수 있다. 또한 배터리는 부동충전시에는 정상적인 특성을 보이지만 방전시 불량 특성이 나타나는 경우가 많고, 리튬-이온 배터리의 경우 내부저항은 수십$[m\Omega]$의 비교적 큰 값을 가지지만 UPS에 적용되는 납축전지의 경우 수$[m\Omega]$ 정도의 아주 낮은 내부저항을 가져 측정오차에 의해 불량 여부를 명확히 판단하지 못하는 경우가 있다. 본 논문에서는 이러한 문제점에 착안하여 평상시에는 배터리의 개별셀 전압, 온도, 전체전압 및 보관함의 온도, 충방전 전류, SOC(State of Charge)를 현장 및 원격지의 모니터링 PC로 전송하여 사용자에게 보여주며, 정전으로 인한 방전시에는 내부저항과 개별셀의 용량을 계산하고 이를 통해 교체시기를 결정할 수 있도록 구성되어 있으며, 실험을 통해 타당성을 확인하였다.

  • PDF

Bilateral Series Resonant Inverter for High Frequency Link UPS (고주파 링크 무정전 교류 전원장치를 위한 직렬 공진형 인버어터)

  • 신봉수;정용호;조규형
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.7
    • /
    • pp.524-538
    • /
    • 1989
  • A new bilateral series resonant inverter and its control method are proposed. The proposed inverter consists of zero current switched cycloconverter. Output voltage is regulated by modulating the average magnitude of resonant current sinusoidally. Cycloconverter synthesizes low frequency output voltage from high frequency resonant current pulses. In the proposed inverter, bidirectional power flow in possible and isolation transformer is miniaturized. The proposed control method is verified through simulation and experiment. The proposed inverter will satisfy the small size and low cost requirements of small Uninterruptible Power Supply (UPS) of less than 1 KVA suitable for micro-computers and electronic equipments used in office and home automation.

The Control of Parallel Operation for Static UPSs (Static UPS 병렬운전 제어)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2048-2050
    • /
    • 1998
  • An uninterruptible power supply(UPS) with parallel operation is used to increase the power capacity of the system or to secure higher reliability at critical loads. In the parallel operating system composed of the multiple UPSs, load-sharing, i.e. current balance control between them is key technique. Because of its low impedance and quick response characteristics, inverter output current changes very rapidly and thereby easily researches an overload condition. The difference between total load current divided by number of operating inverters and its own current is detected as unbalanced current. Then frequency and voltage are controlled to minimize the active component and the reactive component. A good performance of the proposed load-sharing technique is verified by experiments in the parallel operating system with two 40kVA UPSs.

  • PDF

Output LC Filter Design of Single Phase Voltage Source Inverter Used for Uninterruptible Power Supply (무정전전원장치용 단상 전압형 인버터의 출력 LC필터 설계)

  • Min, Wan-Ki;Kim, Jae-Sik;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.83-89
    • /
    • 2007
  • The LC filter design procedure of the inverter output filter is described. The transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant considering the system controller. By using the closed form of the relation between the filter capacitor value and the system time constant, the capacitor value can be calculated with the given system time constant and vice versa. It is more practical for the implementation of power and control circuit of inverter. And as the effect of the load current to the voltage distortion can be calculated from the closed form, it is possible to analyze the system how much the voltage waveform is distorted in case of the nonlinear load. All the proposed design procedure is verified with the simulation and experimental results.

고효율 무정전전원장치

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.291
    • /
    • pp.72-75
    • /
    • 2001
  • 정보네트워크산업이 급속히 발전, 보급되는 가운데 그 전원인 무정전전원장치(Uninterruptible Power Supply: UPS)에 대해서도 여러 가지 요구가 나오고 있다. 특히 최근에는 고신뢰성화$\cdot$소형화$\codt$저가격화에 더하여 러닝코스트 저감과 지구온난화 방지를 연결한 개념의 성에너지화를 목적으로 하는 전력변환효율의 향상에 대한 요구가 강해지고 있다. 이번에 이러한 요구에 응하기 위하여 미쓰비시전기는 상시상용 급전방식을 채용하여 HSS(High Speed Switch)회로와 쌍방향 컨버터회로를 개발하여, 고효율이며 급전신뢰성이 높은 MPC(Multiple Power Compensator)방식의 UPS를 개발하였다. 이에 의하여 전력변환효율을 90$\%$에서 98$\%(100kVA에서)로 대폭 개선함과 동시에 종래의 상용급전방식 UPS의 결점이었던 상용전원 이상시의 급전계통 전환시간을 부하기기에 영향을 미치지 않는 2밀리초까지 단축시켜 전환시에도 순간 단전됨이 없이 부하급전을 계속할 수 있도록 하였다. 또한 통상의 급전시에는 쌍방향 컨버터에 입력전류가 고조파보상기능을 갖게 하여 입력역률 0.99를 달성하였다.

  • PDF

Implementation of Network Management System for Industrial Device (산업설비를 위한 망관리 시스템의 설계)

  • Kang Min-Su;Kwak Dong-Hyun;Jeong Eul-Gi;Jeun Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.693-696
    • /
    • 2002
  • In this paper, network management system(NMS) was developed using Ethernet network for several devices. Recently, due to the development of the information communication, network has been constructed several place. And management system using network has been studied due to the increment of necessity of remote control for industrial device. Agent board that necessity of NMS, was developed using general micro-controller, it operates like stand-alone network device, supports TCP/IP protocol suite, has the ability to connect to industrial device and communicates each other. Also manager base on MMI was developed, it operates with agent board and supports effective management. To prove this system UPS(uninterruptible power supply) is selected as the example of industrial device. Finally, experimental result verifies the communication between agent board and manager.

  • PDF

An Implementation of a Current Controlled Inverter for Improved quality of the Grid (계통의 품질개선을 위한 전류제어형 인버터의 구현)

  • Lee S. S.;Jeon C. H.;Ko S. S.;Shin Y. C.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.515-518
    • /
    • 2004
  • Increasing of the nonlinear power electronics equipments, power conditioning systems have been researched and developed for many years to compensate the harmonic disturbances and the reactive power. The main function of power conditioning systems is to reduce harmonic distortions, since extensive surveys quantify the problems associated with electric networks having non-linear loads. The main function of power conditioner compensates the current instead of the voltage. Therefore the inverter used in power conditioner is mostly the current controlled type. In this paper, we propose the power conditioner using photovoltaic system, which is operated by the PRT(Polarized Ramp Time) current control algorithm. The proposed system could also achieve Demand Side Management's function and Uninterruptible Power Supply's function simultaneously. To verify the proposed current controlled inverter for improved quality of the grid, the detail simulation and experiment results indicate that operation PCS, DSM and UPS can be achieved.

  • PDF