• Title/Summary/Keyword: UPS(Uninterruptible Power Supply System)

Search Result 121, Processing Time 0.027 seconds

Development of 3kW Hybrid ESS with Function of Emergency Power Supply (비상전원 기능을 갖는 3kW급 하이브리드 ESS 개발)

  • Yang, Seok-Hyun;Kim, Min-Jae;Choi, Se-Wan;Cho, Jun-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2015
  • This paper proposes a high-efficiency 3-kW hybrid ESS with emergency power supply. The proposed system enables efficient use of power from photovoltaic (PV) cells and energy storage system (ESS). The proposed system can operate as an uninterruptible power supply (UPS) when grid fault occurs, providing seamless transfer from grid-connected mode to stand-alone mode. The LLC converter for PV achieves ZVS turn-on of switches and ZCS turn-off of diodes, and the isolated bidirectional DC-DC converter for ESS achieves ZCS turn-off regardless of load condition, resulting in high efficiency. The efficiency and performance of the proposed hybrid ESS has been verified by a 3-kW prototype.

DEVELOPMENT OF MULTI-FUNCTIONAL UNINTERRUPTIBLE POWER SUPPLY USING INSULATED GATE BIPOLAR TRANSISTORS (IGBT를 이용한 다기능 무정전전원 공급장치 (UPS)개발)

  • Kim, D.U.;Shin, H.J.;Kim, Y.P.;Baek, B.S.;Ryu, S.P.;Min, B.G.;Choi, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.573-575
    • /
    • 1994
  • Resent research activities and technical trends for UPS(UNINTERRUPTIBLE POWER SUPPLY) are reviewed. There are increasing demands for UPS to get mote useful performance. This needs are high-efficiency, high-confidency, high-quality, low-cost. self-diagnosis. maintenance-free, and a wide variety of options. These can be satisfied with high-technology and optimal system coordination. In this paper. according to these demands. a newly developed UPS and a wide variety of options are introduced. Also. the data related are presented.

  • PDF

The Development of Remote Monitoring & Control System using Modem Uninterruptible Power Supply (모뎀을 이용한 무정전 전원장치(UPS) 원격감시제어시스템 개발)

  • Kim, D.U.;Kim, Y.P.;Shin, H.J.;Baek, B.S.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.445-447
    • /
    • 1997
  • In this paper a remote monitoring and control system using Modem for UPS (Uninterruptible Power Supply) is proposed. The conventional remote monitoring system for UPS is used to local remote monitoring system by RS232 or RS485 communication code. But recently. the system is changed to wide remote monitoring and control system using Modem for quick analysis of errors, correction of errors, report of errors and other user-friendly functions. In this study, we designed and develope system which is able to control UPS an monitor errors, statuses, actual values transmitted from UPSs of each site.

  • PDF

A STUDY ON DEVELOPMENT OF UNINTERRUPTIBLE POWER SUPPLY ADOPTED INSULATED GATE BIPOLAR TRANSISTORS (IGBT를 채용한 무정전전원공급장치 개발에 과한 연구)

  • Baek, B.S.;Kim, Y.P.;Han, G.J.;Ryu, S.P.;Min, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.462-465
    • /
    • 1991
  • In this paper, a newly developed uninterruptible power supply adopted insulated gate bipolar transistors (IGBT'S) is introduced. The focus is on harmonic reduction, high efficiency and so on. The overview, hardware and software of the newly developed ups system are also discussed. Finally, the merit of the newly developed ups compared with conventional ups is described.

  • PDF

A Study on the Uninterruptible Power Supply(UPS) System with Superconducting, Magnet Energy Storage(SMES) (초전도 에너지 저장장치를 이용한 무정전 전원장치 시스템의 연구)

  • Kim, Tae-Wan;Ji, Ho-Chul;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1919-1923
    • /
    • 1997
  • Superconducting magnet energy storage(SMES) offers lower loss and more capacity than other energy storage systems. This paper deals with a configuration and a control method of uninterruptible power supply(UPS) with SMES, Proposed system is constituted of three partsinverter, dc chopper and superconducting coil. The control system is implemented with a general-purpose DSP, TMS320C31. The results of simulation and experiment with a 10kVA prototype show the validity of the system configuration and the control method.

  • PDF

Real Time Digital Control of PWM Inverter for Uninterruptible Power Supply(UPS) application (무정전 전원공급장치 적용을 위한 PWM 인버터의 Digital 실시간 제어)

  • Min, Wan-Ki;Lee, Sang-Hun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.56-60
    • /
    • 1999
  • This paper presents the high performance real time control system of PWM inverter for uninterruptible power supply(UPS). This system is based on a digital control scheme which calculates the pulse widths of the inverter switches for the next sampling time in digital signal processor(DSP). A PI compensator is used to eliminate the voltage error caused by the difference between the actual values of LC filter and those designed. Double regulation loops which are the inner current loop and the outer voltage loop are used to make the transient response time reduce in load disturbance and nonlinear load. This method makes it possible to obtain better response in comparison to conventional digital control system. The proposed scheme provides good performance such as stable operation, low THD of the output voltage, and good dynamic response for load variations and nonlinear load.

  • PDF

Investigation of Dynamic Characteristcs Uninterruptible Power Supply System (UPS) Using Shaking Table Tests (무정전전원장치(UPS)의 진동대 실험 및 동적특성 분석)

  • Lee, Seung-Jae;Kim, Joo-Young;Choi, Kyoung-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.129-136
    • /
    • 2019
  • Non-structural elements are vulnerable to earthquake ground motion. In this study, an experimental study for the electrical non-structural element was performed using tri-axial shaking table tests. A 100kVA UPS(Uninterruptible Power Supply system) was used as the test specimen. The test specimen was anchored to the concrete slab using the conventional installation detail. The input acceleration were generated in accordance with ICC-ES AC156 code. Scale factors of the input acceleration with respect to the required response spectrum defined in ICC-ES AC156 were from 25% to 600%. Based on the test results, damage and dynamic characteristics of UPS were evaluated and analyzed including natural frequency, damping ratio, acceleration time history response, dynamic amplification factor and relative displacement.

Voltage Control in a Novel Three-Phase Line Interactive UPS System with Parallel-Series Active Power Line Conditioning Capabilities using AC Line Reactor (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스뎀의 전압제어)

  • Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1072-1077
    • /
    • 2006
  • In this paper a novel 3-phase line interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) is proposed. And the strategy of voltage control in proposed UPS system is explained. The objective of voltage control in parallel(shunt) and series PWM VSC of proposed UPS system is to guarantee satisfactory characteristics in steady state and transient state.

  • PDF

A study of transient characteristics during the transfer of the source of electric power in UPS (UPS에서 전원 절체시 과도특성에 관한 연구)

  • Lee, Young-Soo;Lee, Kan-Woon;Cha, Jae-Man
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.88-90
    • /
    • 2005
  • There are a lot of troubles during the transfer of the source of electric power in UPS (uninterruptible power supply system) which is indispensable to the industrial equipments. They cause blackout accidents, resulting in a great economic loss. After measuring and analyzing the transient phenomena happening during the transfer, this paper presents the solution of the troubles. The solution can be used as a basic material for maintenance and it can minimize the troubles occurring in UPS and enhance the reliability of it.

  • PDF

C-link Ripple Voltage Compensation Algorithm for Integrated ESS and UPS System with PV Generation (태양광 발전을 갖는 통합 ESS 및 UPS 시스템의 직류 링크 맥동전압 보상 알고리즘)

  • Kim, Min-Gi;Choi, Bong-Yeon;Kang, Jin-Wook;Kim, Jun-Gu;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.443-444
    • /
    • 2014
  • Using the ESS(Energy Storage System) as a UPS(Uninterruptible Power Supply) is being studied recently. When the system is operating at UPS mode in integrated ESS and UPS system, the grid supplying power is disconnected and power from PV generation and battery are supplying to load. Operating in UPS mode, when PV generation power is diminished by partial or total clouded situation, DC-link voltage fluctuates. The fluctuation of DC-link voltage influences the load and system as sensitive loads may malfunction. This paper suggests the DC-link ripple voltage compensation algorithm in bi-directional converter. The algorithm stabilize the DC-link and load voltage.

  • PDF