• Title/Summary/Keyword: UP-SET

Search Result 8,115, Processing Time 0.035 seconds

ON RINGS WHOSE ANNIHILATING-IDEAL GRAPHS ARE BLOW-UPS OF A CLASS OF BOOLEAN GRAPHS

  • Guo, Jin;Wu, Tongsuo;Yu, Houyi
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.3
    • /
    • pp.847-865
    • /
    • 2017
  • For a finite or an infinite set X, let $2^X$ be the power set of X. A class of simple graph, called strong Boolean graph, is defined on the vertex set $2^X{\setminus}\{X,{\emptyset}\}$, with M adjacent to N if $M{\cap}N={\emptyset}$. In this paper, we characterize the annihilating-ideal graphs $\mathbb{AG}(R)$ that are blow-ups of strong Boolean graphs, complemented graphs and preatomic graphs respectively. In particular, for a commutative ring R such that AG(R) has a maximum clique S with $3{\leq}{\mid}V(S){\mid}{\leq}{\infty}$, we prove that $\mathbb{AG}(R)$ is a blow-up of a strong Boolean graph if and only if it is a complemented graph, if and only if R is a reduced ring. If assume further that R is decomposable, then we prove that $\mathbb{AG}(R)$ is a blow-up of a strong Boolean graph if and only if it is a blow-up of a pre-atomic graph. We also study the clique number and chromatic number of the graph $\mathbb{AG}(R)$.

A Review of Math Education about Set based on Stories (이야기에 기초한 유아 집합교육 소고)

  • 김기만
    • Journal of Gifted/Talented Education
    • /
    • v.5 no.2
    • /
    • pp.37-54
    • /
    • 1995
  • The radical development of modern mathematics is due to the appearance of Collection Theory by George Cantor. The Set Theory is independent as an area and also closely interrelated with other areas. So its content becomes a common sense and a basic part across the whole area of modern mathematics. Accordingly, the basic element of modern mathematics is helping young children get familiar with set as early as possible. The thinking of set by which children can categorize, make partial sets and correspondences, understand the general characteristic, and conceptualize the discovered relationships is very important for young children. At this point where the Math education for young children is emphasized under the influence of the modernization movement of Math education, the systematic education for building up the set concept as the basic background of number concept during the early childhood is required. On current mathematics education for young children, graphs, the foundation of geometry, time, and patterns have been included in the traditional and practical content related to numbers. However, the education on collection which is the foundation of number concept is insufficient. A study shows that the level of young children's understanding on set is quite high, but the set concept isn't reflected in current Math curriculum for young children. And basic activities neccesary on building up the set concept, such as categorization, comparison, etc. are conducted in kindergardens but unsatisfactory because of those kindergarden teachers' premature understanding on the set concept. In conclusion, the curriculum for young children should be reorganized based on the set concept as the kernel concept. Also, the reappraisal of the training curriculum and the supplementary efucation for kindergarden teachers are urgent for raising the teaching ability of those kindergarden teachers.

  • PDF

Heuristic Interpretation of the Mean Waiting Time of $Geo^X/G/1$ Vacation Queues with Set-up Time (휴리스틱 방법을 이용한 준비기간을 갖는 휴가형 $Geo^X/G/1$ 모형의 평균대기시간 분석)

  • Lee Sung-H.;Kim Sung-J.;Chae Kyung-C.
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.1111-1115
    • /
    • 2006
  • We present heuristic interpretations of the mean waiting time of $Geo^X/G/1$ vacation queues with set-up time. The heuristic interpretation of the mean waiting time is originally proposed for the continuous-time queues. We demonstrate that the heuristic approach is useful for the discrete-time queues as well.

  • PDF

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

A Study of the Automation of Factory through the Development of UniSet (UniSet개발을 통한 공장자동화에 관한 연구)

  • Park, K.H.;Kim, S.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.2
    • /
    • pp.84-91
    • /
    • 1997
  • This paper reports the effort for developing this new Unified Manufacturing Instruction Set and its environment, called here UniSet, to deal with difficulties in set up and operation of Flexible Manufacturing Cells, UniSet has been developed as a non-exclusive unified manufacturing instruction set based on com- parisons of the prevailing machine tool and programming primitives. UniSet allows programmers to deal with only one instruction set, if they so desire, in a single coherent enviroment, rather than numerous machine programming languges. The software system is coded in an Object-Oriented Programming (OOP) language, Smalltalk, and derives its paradigm from the OO philosophy. Test results are also includ- ed to demonstrate the applicability of the approach employed.

  • PDF

Construction of Improved PCR Primer Set for the Detection of Human Enteric Adenovirus 41

  • Cho, Kyu-Bong
    • Biomedical Science Letters
    • /
    • v.24 no.3
    • /
    • pp.230-238
    • /
    • 2018
  • Human enteric Adenovirus-41 (HuEAdV-41) causes gastroenteritis, which detected by the polymerase chain reaction (PCR) base diagnostic system for clinical, food, environmental, fish and shellfish samples. We developed improved PCR and nested PCR primer set which had high specificity, sensitivity and reduced times. In this study, we compared seventeen conditions reported in the previous study that was using the PCR based HuEAdV-41 detection system, and non-enteric Adenovirus were detected in nine conditions. The most sensitive detection condition was up to 25 copies however it took 184 minutes of PCR reaction time. In this study, the PCR primer set developed had same level of sensitivity, it reduced the time of detection for clinical, food and seafood samples to 112 minutes. Developed nested PCR primer set needed 112 minutes but detected up to approximately 1 copy. In addition, developed PCR and nested PCR primer set was validated with twenty samples of underground water at random, of which ten samples showed specific band without non-specific reaction. We expect this study will be used to diagnose HuEAdV-41 from various samples.

Efficient Fluid Simulation through Various User Design-type Emission Control Solutions (사용자 설계형의 방출 제어 솔루션을 통한 효율적인 유체 시뮬레이션 구현)

  • Hwang, Min-Sik;Lee, Hyun-Seok
    • Journal of Digital Convergence
    • /
    • v.16 no.6
    • /
    • pp.197-204
    • /
    • 2018
  • The realistic Visual Effects using fluid simulation in 3D computer graphics are operated as important factors to improve the quality of images. The process of creating realistic motions of water, fire, explosion by controlling each property of fluid is called fluid simulation. In general, the creation of a fluid simulation concentrates on the main simulation work phase, however an effective method for initial set up is important for the main simulation work. The purpose of this study is to analyze the factors involved in the initial emission motion and shape of fluid and propose methods that can efficiently apply this into the initial set up. For the process of the research, first, problems are raised based on related researches, and second, two experiments, 'Dynamic Fluid Emitter Creation' and 'User Design Type Emission Velocity Solution', are conducted for more effective fluid simulation. Through this research, the effective fluid simulation of initial set up phase will be suggested through the user design-type emission control solutions.

Comparison of occlusal contact areas of class I and class II molar relationships at finishing using three-dimensional digital models

  • Lee, Hyejoon;Kim, Minji;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.45 no.3
    • /
    • pp.113-120
    • /
    • 2015
  • Objective: This study compared occlusal contact areas of ideally planned set-up and accomplished final models against the initial in class I and II molar relationships at finishing. Methods: Evaluations were performed for 41 post-orthodontic treatment cases, of which 22 were clinically diagnosed as class I and the remainder were diagnosed as full cusp class II. Class I cases had four first premolars extracted, while class II cases had maxillary first premolars extracted. Occlusal contact areas were measured using a three-dimensional scanner and RapidForm 2004. Independent t-tests were used to validate comparison values between class I and II finishings. Repeated measures analysis of variance was used to compare initial, set up, and final models. Results: Molars from cases in the class I finishing for the set-up model showed significantly greater contact areas than those from class II finishing (p < 0.05). The final model class I finishing showed significantly larger contact areas for the second molars (p < 0.05). The first molars of the class I finishing for the final model showed a tendency to have larger contact areas than those of class II finishing, although the difference was not statistically significant (p = 0.078). Conclusions: In set-up models, posterior occlusal contact was better in class I than in class II finishing. In final models, class I finishing tended to have larger occlusal contact areas than class II finishing.

X-Ray Triple Crystal Diffraction Spectrometer and Its Applications (X-Ray Triple Crystal Diffraction Spectrometer의 제작과 그 응용)

  • Park Young-Han;Yeom Byo-Young;Yoon Hyng-Guen;Min Suk-ki;Park Young Joo
    • Korean Journal of Crystallography
    • /
    • v.8 no.1
    • /
    • pp.20-25
    • /
    • 1997
  • Two experimental methods have been developed for high resolution measurement of x-ray scattering. The methods used were (1) an x-ray double crystal diffraction (DCD) spectrometer set-up and (2) an x-ray triple crystal diffraction (TCD) spectrometer set-up. With the DCD arrangement of Si(511)-sample(hkl), rocking curves have been plotted for Si (333), Si(004) and GaAs(004). Also, with the TCD arrangement of Si(111)-Si(111)-Si(511)-sample(hkl) including monolithic monocro-collimator and $K_{\alpha1}$ selector, rocking curves have been plotted for Si(333), Si(004) and GaAs(004). The results of FWHM by DCD and TCD set-up have been compared each other and discussed. The reflection topographs (004) and (115) in an $In_{0.037}Ga_{0.0963}As/GaAs$ sample have been obtained by DCD set-up.

  • PDF

The Analysis of the LCL Set-up Parameters for Satellite Power Distribution (위성전원분배를 위한 LCL 동작 파라미터 설정분석)

  • Lim, Seong-Bin;Jeon, Hyun-Jin;Kim, Kyung-Soo;Kim, Tae-Youn
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.56-64
    • /
    • 2011
  • In this paper, the characteristics of LCL set-up parameters for the satellite load distribution are analyzed under the electrical system environment, implemented the LCL circuits and evaluated the performance and its behaviour. Recently, it is implemented the load distribution circuit by latching current limiter(LCL) rather than conventional fuse and relay for the protection of the satellite power system from a fault load. The LCL circuit is composed of the electrical components, not mechanical parts with the fuse and relay. When detected the over current on a fault load, it is activated to maintain the trip-off level for set-up time and then cut-off the load power by the active control. It is more flexible and provided a chance to reuse of the load in case of temporarily event, but the fuse and relay can't be used again after activating due to the physical disconnection. However, for implementation of LCL circuit, it should be carefully considered the behavior of the LCL circuit under the worst electrical system environment and applied it to define the set-up parameters related with over-current inhibition.