• Title/Summary/Keyword: UP-SET

Search Result 8,122, Processing Time 0.035 seconds

Performance Improvement of Triangular-type V-belt Clutch (삼각벨트 클러치의 성능 향상에 관한 연구)

  • 신범수;김상헌;박희찬
    • Journal of Biosystems Engineering
    • /
    • v.24 no.2
    • /
    • pp.99-106
    • /
    • 1999
  • This study was conducted to provide a direction for improving the performance of triangular-type belt clutch. The power transmission characteristics and the wear of belt were investigated for two types of pulley set theoretically and experimentally. The results of research were summarized as follows: 1) Based on the theoretical analysis for the life time of belt, the wear of belt could be reduced by increasing the sizes of driving V-pulley and tension pulley, and by decreasing the tension on V-belt. 2) The pulley set # 2 could transmit more power than the pulley set # 1 could at the same slop rate. While the slip rate was 2.36% on the pulley set # 2 at the maximum power transmission, the slip rate on the pulley set # 1 was increased up to 12.2% at the same condition. 3) From the 16 hours' fatigue test, the wear of belt used n the pulley set # 1 was observed severer than that in the pulley set#2. Also, it was found that the tensile strength of belt used in the pulley set # 2 was greater than that of belt used in the pulley set # 1.

  • PDF

Changes in Total Work, Total Work Ratio, Heart Rate, and Blood Lactate during 75% 1-RM Bench Press Exercise

  • Kim, Ki Hong;Kim, Byung Kwan
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.153-160
    • /
    • 2021
  • Background and Objectives This study was conducted to investigate the change of total work and total work ratio for each set, peak heart rate during exercise, and blood lactate for each set during the 5-set bench press exercise at 75% one repetition maximum test (1-RM). Materials and Methods Seven men in their 20s with more than 6 months of experience doing resistance exercises were selected as subjects, and their 1-RM bench press was measured two weeks before the experiment and 75% 1-RM was measured one week before the experiment. In this study, total work was measured for each set, and heart rate was measured during rest and set-by-set exercise. Blood lactate was measured during rest time after each set. The raw data were analyzed by repeated one-way ANOVA. Results Total work and total work ratio decreased from 1 set to 4 sets (p < .05), p < .001), heart rate increased from stable at the start of exercise (p < .001) and decreased between 3 sets and 4 sets (p < .05). Blood lactate increased continuously up to 2 sets (p < .001, p < .01). Conclusion In conclusion, total work and heart rate decreased with muscle fatigue during exercise, and blood lactate continuously increased. The results of this study are expected to be useful references for constructing resistance exercise programs in the future.

A Study to Evaluate the Efficacy of CBCT and EXACTRAC on Spine Stereotactic Body Radiation Therapy (CBCT와 EXACTRAC을 이용한 Spine SBRT의 유용성 평가)

  • Choi, Woo Keun;Park, Su Yeon;Park, Do Keun;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.167-173
    • /
    • 2013
  • Purpose: This study is to evaluate the efficacy of the CBCT and EXACTRAC the image on the spine stereotactic body radiation treatment. Materials and Methods: The study compared the accuracy of the dose distribution for changes in the real QA phantom for The shape of the body of the phantom was performed. Novalis treatment artificially set up at the center and to the right, on the Plan 1 mm, 2 mm, 3 mm in front 1 mm, 2 mm, 3 mm and upwards 1 mm, 2 mm, 3 mm and $0.5^{\circ}$ by moving side to side Exactrac error correction and error values of CBCT and plan changes on the dose distribution were recorded and analyzed. Results: Cubic Phantom of the experimental error, the error correction Exactrac X-ray 6D Translation in the direction of the 0.18 mm, Rotation direction was $0.07^{\circ}$. Translation in the direction of the 3D CBCT 0.15 mm Rotation direction was $0.04^{\circ}$. DVH dose distribution using the results of the AP evaluate the change in the direction of change was greatest when moving. Conclusion: ExacTrac image-guided radiation therapy with a common easy and fast to get pictures from all angles, from the advantage of CBCT showed a potential alternative. But every accurate information compared with CT treatment planning and treatment of patients with more accurate than the CBCT ExacTrac the location provided. Changes in the dose distribution in the experiment results show that the treatment of spinal SBRT set up some image correction due to errors at the target and enter the spinal cord dose showed that significant differences appear.

  • PDF

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.

Improvement of patient's quality of life by improving patient's set-up line in radiotherapy (방사선 치료 시 환자 Set-up Line 개선을 통한 암환자 삶의 질 만족도 향상)

  • Choi, Jin Hyuk;Ahn, Woo Sang;Lee, Woo Seok;Kim, Dae Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.185-189
    • /
    • 2018
  • Purpose : We evaluated the quality of life satisfaction of patients with radiation therapy while maintaining the set-up line. Materials and Methods : We retrospectively reviewed 60 patients who visited our clinic in January, 2018. The most common complaint was the inconvenience of not being able to wash during treatment (64 %), and a surgical tape was placed on the Set-up Line to help patients wash during the treatment period. A total of 50 patients who underwent surgical tape were evaluated on a 5-point scale (1 point was very unsatisfactory, 2 points were unsatisfactory, 3 points were average, 4 points were satisfied, 5 points were very satisfied). Forty patients out of 50 responded to the first treatment, and 10 patients underwent treatment. Results : In the first survey, 68 % of the patients and 32 % of the males were aged 34 %, 50~60 % and 38 %, respectively. Treatment areas were breast (57 %), chest (13 %), pelvis (10 %). The results of the second questionnaire after applying the surgical tape showed that 25 of the 40 patients and 15 of the male patients were treated. The treatment area was 22 breast and 18 pelvic areas. In the satisfaction of the 5-point scale, 5 to 15 points were satisfied with 1-3 points, and 4-5 points with 35 points (1 point 2 points, 2 points 2 points, 3 point 1 points, 4 point points 17 point points, % And 43 %, respectively. The results of the questionnaire survey of patients who were applied during the treatment showed that 9 out of 10 women and 1 male were treated. The treatment area was 8 breast and 2 pelvic areas. One point was satisfied with one point, and five points with nine points were satisfied with 90 %. Conclusions : The importance of improving the quality of life of patients with cancer is also important. After applying the surgical tape, 88 % of the patients who started the treatment and 90 % of the patients who applied during the treatment were satisfied. Particularly, patients who applied during treatment showed higher satisfaction. If this is not possible for all patients, selective application to patients with discomfort will be helpful in improving the quality of life of cancer patients.

  • PDF