• Title/Summary/Keyword: UM resin

Search Result 74, Processing Time 0.02 seconds

Bone formation of newly developed biphasic calcium phosphate in rabbit calvarial defect model : A pilot study (토끼 두개골에서 새로 개발된 biphasic calcium phosphate의 골형성 효과 : A pilot study)

  • Um, Yoo-Jung;Hong, Ji-Yeon;Kim, Sung-Tae;Lee, Yong-Ho;Park, Sang-Hyun;Park, Sun-Hyo;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.163-170
    • /
    • 2008
  • Purpose: Biphasic calcium phosphates have been of great interest recently. Mixing adequate ratios of hydroxyapatite(HA) and beta-tricalcium phosphate($\beta$-TCP) allowed to control the resorption rate without distorting its osteoconductive property. This study evaluated the bone formation effect of newly developed biphasic calcium phosphate(BCP) in calvarial defect of rabbits. Materials and Methods: 6 male New Zealand rabbits were used. Four defects with 8mm in diameter were created on each animal. BCP with HA/$\beta$-TCP ratio of 7:3 and particle size of $0.5{\sim}1.0\;mm$ was used as the test group and bovine bone with $0.25{\sim}1.0\;mm$ particle size, as the control group. Both test and control group materials were randomly implanted in the calvarial defects and were covered witha polymer membrane. The animals were sacrificed after 12, 24, and 48 weeks of implantation under general euthanasia. Resin blocks were obtained and were stained by masson's trichrome for histological observation. Results: Overall results were uneventful without any defect exposure or inflammation. The amount of new bone formation and bone maturity increased with increase in healing period at both groups. New bone in test group was mostly formed along the material particle surrounded by osteoblasts, and observation of osteoblastic stream was also present. Bone maturity increased as it was closer to thedefect margins. Under the same healing period, the test group showed more bone formation than the control group with more stable bovine bone particles remaining even after 48 weeks, whereas considerable resorption took place in BCP. Almost total defect closure was observed in test group with new bone formation in the central part of the defect. However, limited new bone formation was observed in the control group. Conclusion: Within the limits of the study, the present study reveals the newly developed BCP to be a good osteoconductive material. However, further studies are needed to be conducted in a different study model with a larger sample size.

The Effects of Various Light Intensity on the Polymerization of Resin Composites (광조사 강도의 변화에 따른 광중합 복합레진의 중합반응에 관한 연구)

  • Jun-Gyu Park;Byeong-Hoon Cho;In-Bog Lee;Hyuck-Choon Kwon;Chung-Moon Um
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.86-94
    • /
    • 2001
  • 기존의 광중합기는 높은 광강도를 제공함으로써 광중합 복합레진을 최대한 단축된 시간내의 중합을 목표로 하였다. 이러한 높은 광강도는 복합레진의 중합깊이, 중합률면에서는 우수하나 중합 반응속도가 빠름으로 인해 중합시 응력 발생이 높아진다는 일련의 보고가 있다. 최근에는 광중합 속도를 늦춤으로써 변연적합도 및 중합시 응력 발생을 낮추는 새로운 중합방법들이 제시되고 있다. 이에 본 실험에서는 광조사 강도의 변화가 광중합 복합레진의 중합반응 과정에 미치는 영향 및 중합된 복합레진의 중합률에 대한 영향을 분석하고자 하였다. 5개의 혼합형 광중합 복합레진 (Z-100, Spectrum, Z-250, Clearfil AP-X, P-60)을 사용하였으며 중합시 적용된 광조사 강도에 따라 6개의 실험군으로 정의하였다. 실험군과 이에 따른 광조사 방법은 다음과 같다. 1군은 110mW/$\textrm{cm}^2$로 40초 중합, 2군 210mW/$\textrm{cm}^2$로 40초 중합, 3군 410mW/$\textrm{cm}^2$로 40초 중합, 4군 620mW/$\textrm{cm}^2$로 40초 중합, 5군 110mW/$\textrm{cm}^2$로 10초 중합 후 1분 뒤 620mW/$\textrm{cm}^2$로 30초 중합, 6군 210mW/$\textrm{cm}^2$로 10초 중합 후 1분 뒤 410mW/$\textrm{cm}^2$로 30초 중합하였다. 광중합시 중합 반응 양상에 관한 분석은 시차주사 열계량기를 이용하여 37$^{\circ}C$ 항온상태에서 10분간의 열흐름곡선을 기록하였다. 기록된 열흐름곡선에서 중합 반응시 나타나는 중합열 및 최대 중합열에 이르는 시간을 기록하여 중합반응 속도를 측정하였다. 중합된 복합레진의 중합률은 Fourier Transform Infrared Spectrometer(FTIR)를 이용하였으며 2mm 두께의 복합레진 하방에서의 중합률을 측정하였다. 측정된 결과는 ANOVA 및 Student-Newman-Keuls 방법을 이용하여 유의성을 검증하였다. 실험결과 다음과 같은 결론을 얻었다. 1. 광중합 복합레진 중합시 광조사 강도가 증가할수록 중합열은 증가하였으나 통계적 유의성은 보이지 않았다 (p>0.05). 2. 최대 중합열에 이르는 시간은 광조사 강도가 증가할수록 단축되었다. 이단계 중합방법을 사용한 경우 중합반응 속도를 감소시킬 수 있음을 보였다. 3. 광조사 강도가 증가할수록 중합률은 증가하였다. 이단계 중합방법을 사용한 경우 연속적인 고광강도를 사용한 경우와 유사한 높은 중합률을 보였다. 4. 중합률면에서 광중합복합레진의 중합시 400mW/$\textrm{cm}^2$ 이상의 광강도가 필요한 것으로 나타났다.

  • PDF

The effect of cavity wall property on the shear bond strength test using iris method (Iris 법을 이용한 전단접착강도 측정에서 와동벽의 영향)

  • Kim, Dong-Hwan;Bae, Ji-Hyun;Cho, Byeong-Hoon;Lee, In-Bog;Baek, Seung-Ho;Ryu, Hyun-Mi;Son, Ho-Hyun;Um, Chung-Moon;Kwon, Hyuck-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.170-176
    • /
    • 2004
  • Objectives : In the unique metal iris method. the developing interfacial gap at the cavity floor resulting from the cavity wall property during polymerizing composite resin might affect the nominal shear bond strength values. The aim of this study is to evaluate that the iris method reduces the cohesive failure in the substrates and the cavity wall property effects on the shear bond strength tests using iris method. Materials and Methods : The occlusal dentin of 64 extracted human molars were randomly divided into 4 groups to simulate two different levels of cavity wall property (metal and dentin iris) and two different materials ($ONE-STEP^{\circledR}$ and $ALL-BOND^{\circledR}$ 2) for each wall property. After positioning the iris on the dentin surface. composite resin was packed and light-cured. After 24 hours the shear bond strength was measured at a crosshead speed of 0.5 mm/min. Fracture analysis was performed using a microscope and SEM. The data was analyzed statistically by a two-way ANOV A and t-test. Results : The shear bond strength with metal iris was significant higher than those with dentin iris (p=0.034). Using $ONE-STEP^{\circledR}$, the shear bond strength with metal iris was significant higher than those with dentin iris (p=0.005), but not in $ALL-BOND^{\circledR}$ 2 (p=0.774). The incidence of cohesive failure was very lower than other shear bond strength tests that did not use iris method. Conclusions:The iris method may significantly reduce the cohesive failures in the substrates. According to the bonding agent systems. the shear bond strength was affected by the cavity wall property.

Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin (광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구)

  • Choi, Yong-Hoon;Bae, Ji-Hyun;Son, Ho-Hyun;Lee, In-Bog;Um, Chung-Moon;Baek, Seung-Ho;Kim, Oh-Young;Kim, Chang-Keun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.177-184
    • /
    • 2004
  • Objectives : This study investigated the hypothesis that increasing light-curing time would leave the oxygen-inhibited layer (OIL) of the adhesive thinner, and in turn, result in lower shear bond strength (SBS) than those obtained by the routine curing procedures. Methods:120 human extracted posterior teeth were randomly divided into three groups for bonding with three adhesives:All Bond 2/sup (R)/, One Step/sup (R)/, and Adper Prompt/sup (R)/. They were subsequently divided into four subgourps with different light-curing time (10, 20, 30 and 60s). The assigned adhesives were applied on superficial occlusal dentin according to the manufacturer's instructions and cured with one of the four curing times. Composite resin cylinder, 2.35㎜ in diameter, were built on the cured adhesive and light-cured for 40s. SBS were measured after 24h from the bonding using a universal testing machine (crosshead speed 1.0 ㎜/min). The relative thickness of the OIL and the degree of conversion (DC) were determined from the adhesive on a slide glass using FT-NIR in an absorbance mode. Data were analysed with One-way ANOVA and Duncan's multiple test (p〈0.05), Results:With increasing cure time, although there were no significant difference in th SBS of One-step and Adper Prompt (p〉0.05), those of All Bond 2 decreased significantly (p〈0.05). The relative thicknesses of the OIL on each adhesive were not affected by the cure time (p〉0.05). Although the DC of All-Bond 2 were statistically not different with increasing cure time (p〉0.05), those of One-Step and Adper Prompt showed an increasing trends with increasing cure time (p〈0.05). Conclusions:Increasing light-curing time did not affect on the relative thickness of the OIL of the adhesives, and in turn, on the SBS to dentin.