• Title/Summary/Keyword: UHI

Search Result 48, Processing Time 0.026 seconds

The Relationship between Temperature Patterns and Urban Morfometri in the Jakarta City, Indonesia

  • Maru, Rosmini;Ahmad, Shaharuddin
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.128-136
    • /
    • 2015
  • Sky View Factor (SVF) is one of the urban morfometri parameters that impact on the Urban Heat Island (UHI). SVF analisys was conducted in the city of Jakarta to investigate the relationship between urban temperature with urban morfometri. Jakarta City is the most populous city in the world that has a surrounding area $66,152km^2$ and the total population around 23 million people. The population of the city is the sixth highest in the world today. SVF measurements done by taking pictures at the six stations that have different morphological characteristics namely (1) the narrow streets Apartment Cempaka Mas (JS ITC), (2) the width of the road Apartment Cempaka Mas (JL ITC), (3) in front of Colleges Kanisius (DKK), (4) in front of office Journalist of Indonesia (DKWI), (5) Utan Kayu (UK), and (6) Tambun (TB). SVF value is obtained from the photgraphic image. Taking pictures at the location using a Nikon D90 camera with a Nikon Fisheye Nikkor 10.5 mm 1 : 2.8 G ED, further processed through a global mapper program. Therefore, the SVF derived from the six stations that vary 0.21 to 0.78. Temperature measurement is done during daylight hours from 06:00 am to 18:00 pm during the Western Part of Indonesia (WIB). Measurements performed at three different times, namely working days (HK) regular holidays (HCB) national holidays (HCN). The results showed that the highest average temperature of $33.32^{\circ}C$, occurring at UK station (SVF=0.45) at the time of HCB. Meanwhile, the average low temperature of $31.22^{\circ}C$ occurred at JLITC station (SVF=0.42). The two-time occurred on ordinary holidays. Maximum temperature of $38.4^{\circ}C$ occurred in Utan Kayu station (SFV=0.45) that occurred at 11.00 hrs, normal holidays. Furthermore minimum temperature 24.5 occurred at Tambun station (SVF=0.78) at 06.00 hrs in the morning at the usual holidays and national holidays. In general, the results showed that areas with large SVF has a lower temperature compared with areas with smaller SVF. Though, are not the only factors that matter, but this research may show that an increase in temperature in the city of Jakarta. Therefore, it is necessary to mitigate the serious from the government or society.

High-resolution Simulation of Meteorological Fields over the Coastal Area with Urban Buildings (건물효과를 고려한 연안도시지역 고해상도 기상모델링)

  • Hwang, Mi-Kyoung;Kim, Yoo-Keun;Oh, In-Bo;Kang, Yoon-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.137-150
    • /
    • 2010
  • A meso-urban meteorological model (Urbanized MM5; uMM5) with urban canopy parameterization (UCP) was applied to the high-resolution simulation of meteorological fields in a complex coastal urban area and the assessment of urban impacts. Multi-scale simulations with the uMM5 in the innermost domain (1-km resolution) covering the Busan metropolitan region were performed during a typical sea breeze episode (4~8 August 2006) with detailed fine-resolution inputs (urban morphology, land-use/land-cover sub-grid distribution, and high-quality digital elevation model data sets). An additional simulation using the standard MM5 was also conducted to identify the effects of urban surface properties under urban meteorological conditions. Results showed that the uMM5 reproduced well the urban thermal and dynamic environment and captured well the observed feature of sea breeze. When comparison with simulations of the standard MM5, it was found that the uMM5 better reproduced urban impacts on temperature (especially at nighttime) and urban wind flows: roughness-induced deceleration and UHI (Urban Heat Island)-induced convergence.

Analyzing the Stream Thermal Environmental Characteristic in Cheongju City using Quick-bird and Landsat Imagery (Quick-bird와 Landsat영상을 하천 주변의 열환경 특성 분석)

  • Na, Sang-Il;Park, Jong-Hwa;Park, Jin-Ki
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2023-2027
    • /
    • 2008
  • 교통과 산업의 발달로 농촌인구의 감소가 빠르게 진행되고, 도시로 유입된 인구의 거주 공간 확보를 위해 도시주변의 피복 변화가 빠르게 진행되고 있다. 도시 지표의 대부분이 아스팔트나 콘크리트 등으로 피복되어 있어 도심의 기온이 교외와 비교하여 높게 형성되는 도시열섬현상(urban heat island, UHI)이 두드러지고 있다. 따라서 도시열섬현상 해소 대책으로 다양한 방법들이 분야 별로 제안되고 있다. 본 연구에서는 청주시 소재(미호천과 무심천을 대상으로) 하천으로 부터 떨어진 거리에 따른 열환경에 대하여 토지 피복에 따른 공간적 특성 분석을 수행함으로서 하천이 도심지 열 환경에 미치는 영향에 대하여 조사하였다. 하천을 중심으로 $0{\sim}1000m$ 까지 200m 간격의 버퍼를 생성하고 Landsat 영상에 의한 NDVI와 온도분포도를 이용하여 청주시 하천의 근접성에 따른 NDVI 및 온도 분포 분석 결과, NDVI는 하천을 기준으로 거리가 멀어질수록 점차적으로 증가하는 경향을 보였고 온도는 감소하는 것으로 나타났다. 또한 Quick-bird 영상에 의한 토지피복도와 NDVI, 온도 데이터를 중첩분석한 결과 NDVI는 산림-경작지-초지-나지-시가지 및 건조지 순으로 나타났고 평균온도는 NDVI의 역순으로 나타났다. 특히, 시가지를 비롯하여 공업지, 상업지 등 건조지역과 나지는 평균 $24^{\circ}C$ 이상으로 인구밀집지역은 높은 온도분포를 나타내는 것을 알 수 있었다.

  • PDF

Surface Micro-Climate Analysis Based on Urban Morphological Characteristics: Temperature Deviation Estimation and Evaluation (도시의 지표형태학적 특성에 기반한 지면미기후 분석: 기온추정 및 평가)

  • Yi, Chaeyeon;An, Seung Man;Kim, KyuRang;Kwon, Hyuk-gi;Min, Jae-Sik
    • Atmosphere
    • /
    • v.26 no.3
    • /
    • pp.445-459
    • /
    • 2016
  • Air temperature deviation (ATD) is one of major indicators to represent spatial distribution of urban heat island (UHI), which is induced from the urbanization. The purpose of this study is to evaluate the accuracy of air temperature deviation about Climate Analysis Seoul (CAS) workbench, which had developed by National Institute Meteorological Science and TU Berlin. Comparison and correlation analysis for CAS ATD including meso-scale air temperature deviation, local-scale air temperature deviation, total air temperature deviation, surface heat flux deviation, cold air production deviation among meso-scale numerical modelling variable in 'Seoul Region', micro-scale numerical modelling in 'Detail Region', and CAS workbench variable using observation data in ground stations. Comparison between night time OBS ATD and CAS ATD show that have most close values. Most of observations ($dT_{max}$ and $dT_{min}$) have highly positive ($dT_{SHP}$, $dT_{CA}$, MD, TD, $f_{BS}$, $f_{US}$, $f_{WS}$, $h_B$) and negative ($f_{VS}$, $f_{TV}$, $h_V$, Z) correlations. However, CAS workbench needs further improvement of both observational framework and analytical framework to resolve the problems; (1) night time OBS ATD of has closer values in compare with at high rise mountain area and (2) correlations are very dependable to meteorological scale.

Investigation of Urban Environmental Quality Using an Integration of Satellite, Ground based measurement data over Seoul, Korea

  • Lee, Kwon-Ho;Wong, Man-Sing;Kim, Young-J.
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.3
    • /
    • pp.339-351
    • /
    • 2011
  • This study investigates the potentials of satellite, ground measurement data, and geo-spatial information within an urban area for the mapping of the Urban Environmental Quality (UEQ) parameters. The UEQ indicates a complex and various parameters resulting from both human and natural factors, which are greenness, climate, air pollution, the urban infrastructure, and etc. Multi-spectral remote sensing data from the Landsat ETM and TM sensors for the mapping of air pollution by the Haze Optimized Transform (HOT) technique, Urban Heat Island (UHO using the emissivity-fusion method in Seoul from 2000 to 2006 in fine resolution (30m) were analyzed for the estimation of UEQ index. Although the UHI values are similar ($8.4^{\circ}C{\sim}9.1^{\circ}C$) during these years, the spatial coverage of "hot" surface temperature (> $24^{\circ}C$) significantly increased from 2000 to 2006 due to the rapid urban development. Furthermore, high correlations between vegetation index and land surface temperature were achieved with a correlation coefficients of 0.85 (2000), 0.81 (2001), 0.84 (2002), and 0.89 (2006), respectively. It was found that the proposed method was successfully analyzed spatial structure of the UEQ and the scenarios of the best and worst areas within the city were also identified. Based on the quantifiable fine resolution satellite image parameters, UEQ can promote the understanding of the complex and dynamic factors controlling urban environment.

Air Temperature Differences in Areas with High-rise Buildings (초고층빌딩지역의 기온차)

  • Jin, Wen-Cheng;Lee, Kyoo-Seock
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.12-22
    • /
    • 2012
  • In Seoul, skyscrapers are built in commercial zones known as residential-commercial complexes, which cause such environmental problems as urban heat islands(UHI) and air pollution. To investigate air temperature differences in areas near skyscrapers at Gangnam-gu, Seoul, South Korea, fixed air temperature observation and traverse observations were performed from March 16, 2008 to March 15, 2009. The annual mean air temperature at Tower Palace(TPL) was higher than that at Sookmyung Girls' High School(SMG) by $0.7^{\circ}C$, although the distance between the two observation positions is only 200m. The number of tropical nights at TPL was 13, while that at SMG was 5. The higher air temperature at TPL was due to a significantly lower sky view factor(SVF), which prevented long-wave radiation from emitting into the sky. The highest air temperature increases near TPL occurred on summer nights because of the high-electricity consumption value of $70.22Wh/m^2$ for the TPL block in August due to air conditioning for cooling. It is concluded that the warm air pocket centered on TPL.

Analysis of Urban Heat Island (UHI) Alleviating Effect of Urban Parks and Green Space in Seoul Using Deep Neural Network (DNN) Model (심층신경망 모형을 이용한 서울시 도시공원 및 녹지공간의 열섬저감효과 분석)

  • Kim, Byeong-chan;Kang, Jae-woo;Park, Chan;Kim, Hyun-jin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.4
    • /
    • pp.19-28
    • /
    • 2020
  • The Urban Heat Island (UHI) Effect has intensified due to urbanization and heat management at the urban level is treated as an important issue. Green space improvement projects and environmental policies are being implemented as a way to alleviate Urban Heat Islands. Several studies have been conducted to analyze the correlation between urban green areas and heat with linear regression models. However, linear regression models have limitations explaining the correlation between heat and the multitude of variables as heat is a result of a combination of non-linear factors. This study evaluated the Heat Island alleviating effects in Seoul during the summer by using a deep neural network model methodology, which has strengths in areas where it is difficult to analyze data with existing statistical analysis methods due to variable factors and a large amount of data. Wide-area data was acquired using Landsat 8. Seoul was divided into a grid (30m × 30m) and the heat island reduction variables were enter in each grid space to create a data structure that is needed for the construction of a deep neural network using ArcGIS 10.7 and Python3.7 with Keras. This deep neural network was used to analyze the correlation between land surface temperature and the variables. We confirmed that the deep neural network model has high explanatory accuracy. It was found that the cooling effect by NDVI was the greatest, and cooling effects due to the park size and green space proximity were also shown. Previous studies showed that the cooling effects related to park size was 2℃-3℃, and the proximity effect was found to lower the temperature 0.3℃-2.3℃. There is a possibility of overestimation of the results of previous studies. The results of this study can provide objective information for the justification and more effective formation of new urban green areas to alleviate the Urban Heat Island phenomenon in the future.

Analysis of Microclimate Impact According to Development Scenarios of Vacant Land in Downtown Seoul - A Comparison of Wind Speed and Air Temperature - (서울 도심 공지의 개발 시나리오에 따른 미기후 영향 분석 - 풍속 및 기온 비교 -)

  • Baek, Jiwon;Park, Chan;Park, Somin;Choi, Jaeyeon;Song, Wonkyong;Kang, Dain;Kim, Suryeon
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.2
    • /
    • pp.105-116
    • /
    • 2021
  • In the city of high population density crowded with buildings, Urban Heat Island (UHI) is intensified, and the city is vulnerable to thermal comfort. The maintenance of vacant land in downtown is treated as a factor that undermines the residential environment, spoils the urban landscape, and decreases the economic vitality of the whole region. Therefore, this study compared the effects on microclimate in the surrounding area according to the development scenarios targeting the vacant land in Songhyeon-dong, Jongno-gu, Seoul. The status quo, green oriented, building oriented and green-building mediation scenarios were established and ENVI-met was used to compare and analyze the impact of changes in wind speed, air temperature and mean radiant temperature (MRT) within 1 km of the target and the target site. The result of inside and 1 km radius the targeted area showed that the seasonal average temperature decreased and the wind speed increased when the green oriented scenario was compared with the current state one. It was expected that the temperature lowered to -0.73 ℃ or increased to 1.5 ℃ in summer, and the wind speed was affected up to 210 meters depending on the scenario. And it was revealed that green area inside the site generally affects inside area, but the layout and size of the buildings affect either internal and external area. This study is expected to help as a decision-making support tool for developing Songhyeon-dong area and to be used to reflect the part related to microclimate on the future environmental effects evaluation system.