• Title/Summary/Keyword: UHF signal

Search Result 135, Processing Time 0.03 seconds

A Cancellation Technique of TX Leakage Signal for Emhanced Readability in UHF-band RFID Readers (UHF대역 RFID Reader에서 인식률 향상을 위한 송신누설신호 상쇄기술)

  • Noh, Eui-Ho;Lee, Jong-Hyuk;Kim, Nam-Yoon;Kim, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.5A
    • /
    • pp.543-550
    • /
    • 2011
  • In order to improve readability, a leakage-signal canceller has been proposed in UHF-band RFID readers. The proposed canceller is composed of two blocks: an environment monitoring block for detection of Tx and RX power levels and a leakage cancellation block. The leakage canceller consists of directional-couplers, digital attenuators and phase shifters based on the feed-forward scheme. The leakage canceller is located between antenna and reader. An improved experimental characterization of the scheme is presented with results from the reader operating in the Korean RFID frequency band, conforming the validity of the approach with more than 29 dB of leakage cancellation.

Localization of partial discharge in power transformer by detecting UHF PD signal (UHF 부분방전 신호를 이용한 전력용 변압기 내부의 부분방전 위치 추정)

  • Ju, Hyung-Jun;Goo, Seun-Gun;Han, Ki-Sun;Park, Ki-Jun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.147-148
    • /
    • 2008
  • In this paper two kinds of techniques were compared for localization of PD(partial discharge) in power transformer and more useful method was suggested. Both of them, the time of arrival and the energy content method, were tested in 154kV single phase experimental transformer using UHF signal measurement. The former was using the difference of arrival time of recorded signals from four UHF sensors, the latter was based on the energy content in frequency spectra of signals detected at all sensors.

  • PDF

Spectrum analysis of UHF Signals Generated by Defects in a Simulated GIS (모의 GIS 결함에 따른 UHF 신호의 스펙트럼 분석)

  • Joun, J.K.;Kwak, H.R.;Roh, Y.S.;Kim, D.S.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1797-1799
    • /
    • 2003
  • In this paper, we measured partial discharge inception voltage(PDIV) and frequency spectra of UHF signal under following three cases, (1) a corona discharge due to a non uniform electric field for needle-plate electrode (2) a surface discharge caused by particles attached to a spacer in GIS, (3) free movements of particle in GIS. As a result of the experiment, it was revealed that the PDIV of Case (3) is higher than PDIVs of Case (1) and Case (2). It was also seem that UHF signal frequency spectra of one case are different from those of the other cases.

  • PDF

Fingerprint-Based Indoor Logistics Location Tracking System (핑거프린트에 기반한 실내 물류 위치추적 시스템)

  • Kim, Doan;Park, Sunghyun;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.7
    • /
    • pp.898-903
    • /
    • 2020
  • In this paper, we propose an indoor logistic tracking system that identifies the location and inventory of the logistics in the room based on fingerprints. Through this, we constructed the actual infrastructure of the logistics center and designed and implemented the logistics management system. The proposed system collects the signal strength through the location terminal and generates the signal map to locate the goods. The location terminal is composed of a UHF RFID reader and a wireless LAN card, reads the peripheral RFID signal and the signal of the wireless AP, and transmits it to the web server. The web server processes the signal received from the location terminal and stores it in the database, and the user uses the data to produce the signal map. The proposed system combines UHF RFID with existing fingerprinting method to improve performance in the environment of querying multiple objects.

Performance Evaluation of SHF Sensor for Partial Discharge Signal Detection on DC Rectifier (DC 정류기 부분방전 신호검출을 위한 SHF 센서의 성능평가)

  • Jung, Ho-Sung;Park, Young;Na, Hee-Seung;Jang, Soon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1056-1060
    • /
    • 2012
  • Online monitoring system is becoming an essential element of railway traction system for utilized to condition based malignance management and various techniques currently employed in railway traction system. Among the various techniques, it is efficient to detect partial discharge signals by electromagnetic wave detection in order to detect insulation fault of rectifier. Although VHF (Very High Frequency), UHF (Ultra High Frequency) sensors were adopted to detect partial discharge of power facilities, due to characteristics of urban railway, excessive noise occurs from 500 MHz to 1.5 GHz on UHF bandwidth. In this paper a new measurement system able to monitoring the conditions of power facilities on DC substation in metro was studied and set up. The system uses UHF sensors to measure the partial discharge of the rectifier due to electric faulting and dielectric breakdown. Comparison and estimation for performance of SHF sensor which had devised to detect partial discharge signal of urban railway rectifier has conducted. In order to estimate performance of SHF sensor, we have compared the sensor with existing UHF sensor on sensitivity upon frequency bandwidth generated by pulse generator, and also we have verified performance of the SHF sensor by detection results of partial discharge signal from urban railway rectifier.

The CE101 Test of the Army Aircraft's UHF Band Transceiver (육군 항공기류 UHF 대역 송수신기 CE101 시험)

  • Seo, Jung-Won;Jung, Byoung-Koo;Yoon, Chang-Bae;Shin, Young-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.11
    • /
    • pp.992-998
    • /
    • 2015
  • In case of UHF Band Transceiver for Army Aircraft, it shall follow MIL-STD-461F Figure CE101-4 most key design points for this equipment were to minize the current consumption and frequency interference since it will be integrated on aircraft. However, after design, abnomal signal(over 100 dBuA) was occured from 30 Hz to 1 kHz on CE101 test. Occured abnomal signal was measured as 50 Hz signal which was tansceiver $T_{DD}$ signal with the output power of 10 W and 20 ms periods. To meet the specification, current variation needed to be minized. Thus, $I_{dq}$ and $I_d$ of power amplifier were modified almost equally through test result and finally, the equipment was designed and developed with no difference of current consumption and frequency interference from the previous design goal.

UHF Sensor Development for Partial Discharge Exclusively for Measurement in 25.8kV GIS (25.8kV GIS 부분방전 측정전용 UHF센서 개발)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1083-1088
    • /
    • 2016
  • 25.8kV GIS part generated by sensors to measure contact an inflow of noise depending on the extent of the measured discharge occurs often not easy. Partial discharge signal measurement sensor suitable for developing a more useful measurements at the scene to this, partial discharge waveform analysis developed a sensor, and to utilize forSensor on the development of the most important is VSWR decided to (voltage standing wave ratio) voltage standing-wave ratio less than 1.5 and decided less than at the full spectrum bands that are measured, this time Return loss, as measured value by absolute criteria 14.0 dB produced the sensor, designed to or more. UHF 1.5~0.5 GHz bandwidth spectrum to be measured in GIS. UHF bands were designed to be able to measure the best signal. Recently, 25.8kV GIS production company has been increasing variety of GIS were made open spacer in partial discharge in accordance with the not very easy to detect the signal. The sensor is designed height of four cm external spacer is attachment GIS in an influx of outside noise measurement, and be so manufactured as to facilitate the least we've done. Also, since partial discharge which occur can measure the frequency of the 170kV GIS external partial-discharge signals that occur at the scene of insulation applied to the spacer. Features, and also derived good results using global positioning. Also measured discharge point about sensors that are stable and the reliability of the development and local substation equipment failure occurring signal analysis through the discharge for the prevention of widely. There should be to believe that used.

Read Range Reduction in Passive UHF RFID Tag by Smart Device Signal Interference (스마트 기기 신호 간섭에 의한 수동형 UHF 대역 RFID 태그의 인식 거리 감소에 관한 연구)

  • Kwon, Jongwon;Song, Taeseung;Cho, Wonseo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.83-91
    • /
    • 2014
  • The passive UHF RFID tags for item-level tagging are now explosively used in the supply chain and retail applications as they have several advantages, the two most relevant are cost and a longer read range. However, the signal interference problem between RFID tags and smart devices in real world is expected according to the smart-phone and tablet market growth together. The performance of RFID tags can be significantly less. The popular examples are the read-success rates and read range reduction. Especially, KT Corp. recently emphasized the serious signal interference at 900 MHz of LTE and old RFID frequencies through their public demonstration. By popular demands, this paper suggests the interference tolerance measurement method between the passive UHF RFID tag and the transmitted signal from a smart device. In addition, we selected three passive UHF RFID tags(Inlay) available on the market and quantitatively evaluated read range reduction results by interference signals using the PCR(Performance Change Rates) index. As a result, the LTE system is about three times as effective as the WCDMA system in terms of interference effects, and the read range performance of two RFID tags about 60 % drop.

Development and characterization of a ultra-wide bandwidth video detector for the UHF partial discharge monitoring system (UHF 부분방전 감시 장치를 위한 초광대역 검출장치 개발 및 특성조사)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1649-1651
    • /
    • 2002
  • Ultra-wide bandwidth (UWB) detection method has been widely used as a front end detection scheme for the ultra-high frequency (UHF) partial discharge (PD) monitoring systems. A broad-band video detector module was developed and characterized for the UHF UWB PD detection systems. The useable bandwidth of the module is more than 2 GHz and it is optimized for 50-ohm systems. The detection sensitivity and dynamic range of the module were characterized by using a known ns-width RF pulses of GHz range. The dynamic range is more than 6-decades and the module can detect pulsed RF signals down to 1 nW. The detector module can eliminate expensive equipment such as high speed oscilloscopes and radio frequency (RF) spectrum analyzers. Therefore, it enables one to use slow speed data acquisition systems for the PD monitoring at the UHF range. The detector module was used to detect real PDs of about <3 pC. The module converts the UWB PD signals into a low-bandwidth video signal with a high signal-to-noise ratio.

  • PDF

Study on the UHF-band Variable Attenuator Using the 3-dB Coupler (UHF대역 3-dB 커플러(Coupler)를 이용한 가변 감쇄기(Attenuator)에 대한 연구)

  • 박경태
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.68-74
    • /
    • 2001
  • A design and implementation method for the UHF-band(800MHz) variable attenuator using the 3dB coupler is proposed. The 90 degree, 3-dB Coupler is used for the variable attenuator. The principal theory for the 3-dB coupler is introduced. The 3-dB Coupler is designed by the mathematical analysis and a computer simulation tool. A PIN diode is used for the variable resistor at UHF-band. The variable attenuator using the 3-dB coupler and the PIN diode is designed and implemented. The measured results for the variable attenuator by a network analyzer show that the insertion loss is below -l0dB, and the continuous variable attenuation range is about 10dB.

  • PDF