• 제목/요약/키워드: UHF Band

검색결과 277건 처리시간 0.024초

A Study on the Pattern Recognition Rate of Partial Discharge in GIS using an Artificial Neural Network

  • Kang Yoon-Sik;Lee Chang-Joon;Kang Won-Jong;Lee Hee-Cheol;Park Jong-Wha
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권2호
    • /
    • pp.63-66
    • /
    • 2005
  • This paper describes analysis and pattern recognition techniques for Partial Discharge(PD) signals in Gas Insulated Switchgears (GIS). Detection of PD signals is one of the most important factors in the predictive maintenance of GIS. One of the methods of detection is electro magnetic wave detection within the Ultra High Frequency (UHF) band (300MHz $\~$ 3GHz). In this paper, PD activity simulation is generated using three types of artificial defects, which were detected by a UHF PD sensor installed in the GIS. The detected PD signals were performed on three-dimensional phi-q-n analysis. Finally, parameters were calculated and an Artificial Neural Network (ANN) was applied for PD pattern recognition. As a result, it was possible to discriminate and classify the defects.

UHF 대역에서 가스절연 개폐장치의 주요 결함별 부분방전 신호 특성 연구 (Characteristics of Various PD Signatures due to GIS Defects in UHF Band)

  • 구선근;임재섭;박기준;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.59-62
    • /
    • 2004
  • 가스절연개폐장치에서 발생하는 고장을 조기에 예방하기 위해서는 방전신호를 분석하여 방전을 일으키는 결함을 유추하는 것이 핵심 기술이다. 본 논문에서는 UHF 대역에서 알고 있는 결함에 의한 방전신호를 측정하여 다양한 가시화 방법으로 방전유형을 분류, 정리함으로써 미지의 방전신호로부터 방전원인을 추정할 수 있도록 하였다.

  • PDF

UHF RFID 기술을 이용한 자전거 주차 관리 시스템 개발 (Development of Bicycle Parking Management system using UHF RFlD Technology)

  • 정병호;김상철
    • 디지털산업정보학회논문지
    • /
    • 제7권2호
    • /
    • pp.9-17
    • /
    • 2011
  • In this paper, a bike management system using 900 MHz RFID technology has been developed. There are limits to the 13.56 MHz spectrum of existing management systems, which are single tag identification and the short possible identifying distance of the technology. In this paper, we use 900 MHz instead of 13.56 MHz in order to make wide recognition and multi-tag identification possible. Granted, there are also many benefits to using 13.56 MHz RFID tags, which include compatibility with existing bike management systems. This system was developed on the 900 MHz band using RFID similarly to existing 13.56 MHz systems in order to be able to manage multiple bikes at the same time.

Design of a Tag Antenna for UHF RFID Food Systems

  • Shin, Dong-Beom;Lee, Jung Nam;Lee, Heyung-Sub;Lee, Sang-Yeoun;Kim, Byeong-Sam
    • Journal of electromagnetic engineering and science
    • /
    • 제13권4호
    • /
    • pp.208-213
    • /
    • 2013
  • This paper proposes a tag antenna for radio frequency identification (RFID) food system. The RFID tag antenna is designed and fabricated based on the rectangular loop concept used in the UHF band (Korean and Japanese standards, 916.7-923.5MHz). The proposed tag antenna is composed of a radiation patch, sensor tag chip, temperature sensor, oscillator, and battery. We conjugated matching between the tag antenna and the sensor tag using a U-shaped stub. Details of the proposed tag antenna design and the simulated and measured results are presented and discussed.

GIS 부분방전 측정용 UWB UHF 커플러에 관한 연구 (A study on the development of a UWB UHF coupler for GIS PD detection)

  • 최재구;김익수;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1776-1778
    • /
    • 2003
  • Partial Discharge(PD) pulses propagate in gas insulated substation(GIS) with rise time shorter than one nanosecond. Therefore, Ultra high frequency(UHF) couplers which have ultra wide band(UWB) characteristics from hundreds of MHz to several GHz are desirable for the detection of the PB pulses in GIS. In this paper, the authors proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, coupler geometry were considered through the simulations and the experiments together.

  • PDF

EMTP를 이용한 GIS내 부분방전 펄스의 감쇠특성 해석 (Analysis of Partial Discharge Pulse Damping Characteristics in GIS Using EMTP)

  • 이도훈;김재철;송승엽;신중은;노광현;김광화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.103-105
    • /
    • 2003
  • The principle of the ultra-high frequency (UHF) method to detect partial discharge(PD) in GIS is to measure the UHF electromagnetic waves excited by PD pulses. Such electromagnetic waves propagate along the GIS busbar in the TEM-mode, TE-mode, TM-mode. And the coaxial busbar of the GIS acts as a waveguide in which the UHF electromagnetic waves travel. This paper was studied the analysis on damping characteristic of electromagnetic waves excited by PD in GIS and presented the method to yield the cutoff frequency for determine the minimum band of sensor that detect the PD pulse.

  • PDF

재난음성통신을 위한 Modular 3-Band RF 개발 (Implementation of Modular 3-Band RF for Disaster Voice Communication)

  • 박진희;이순화
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권6호
    • /
    • pp.23-28
    • /
    • 2013
  • 재난은 다양성과 대규모성 및 예측불가성을 가지고 있어, 사전 예측이 매우 어렵기 때문에 재난 발생후 신속한 대응으로 재해를 줄이는 것이 매우 중요하다. 신속한 재난 대응을 위해서는 재난현장에서 현장요원들간의 상황 정보 공유와 업무 협조를 위한 재난통신은 매우 필수적인 기술이다. 우리나라는 100MHz의 VHF 대역, 400MHz의 UHF 대역, 800MHz 대역 일부의 무선 주파수를 재난통신 영역으로 정의하고 이러한 RF 대역을 사용하는 이종의 무전기를 혼용하고 있어서 하나의 무전기로 상호 통신이 어려워 현장요원들이 여러 대의 무전기를 소지해야 하는 문제점이 발생한다. 하나의 무전기로 이종의 무전기간에 상호교신을 하기 위해서는 음성통신 연계 기술이 매우 필요하다. 본 논문에서는 단일 안테나를 통해 다수의 이종 무전기간 상호 음성 통신이 가능하기 위한 모듈러 3-Band RF를 개발하였으며, 제안한 방식을 통해 장착하는 무전기 수에 대해 확장성을 확인하였다.

광대역 및 협대역을 동시에 사용하는 부분방전 측정 시스템 모듈 개발 (Development of Partial Discharge Measuring System Module by use of Wide and Narrow Band)

  • 이종오;유경국;신인권;장덕진;안창환
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.98-103
    • /
    • 2015
  • Power plant is that very high reliability when industrial and economic impact on the overall electric power system is required, it is essential to improve the reliability, especially the fault prediction diagnosis. Since an accident caused by the partial discharge in the power plant is above state has a faster response characteristic than the other indications in the case of any, the partial discharge generated in the power plant immediately detect the deterioration of insulation due to the accident of the power plant and the non-drawn It should prevent or reduce. Partial Discharge Measuring Systems for UHV SF6 Gas Insulated Switchgear and power transformer on site installed has some probability of abnormal recognition in case of non-flexible deal with on site noise. Many methode to eliminate these kinds of noises, UHF Detection System is chosen as purchase description in Korea, but this system having a bandwidth between 500MHz 1.5GHz wide band. Initial install periods(about 20 years ago), this band had no strong signal source, but in these days this wide band have strong signals, such as LTE. So, module described in this paper is designed as simultaneously use with wide and narrow band for solve this noise problem, and introduce this system.

UHF 대역 장거리 항공 통신 시험의 전파 손실 분석 (Analysis of UHF-Band Propagation Loss in Long-distance Air-to-Ground Communication Tests)

  • 장민수;김규환;김재환;이재문;황찬호
    • 한국산학기술학회논문지
    • /
    • 제19권8호
    • /
    • pp.55-63
    • /
    • 2018
  • 본 논문에서는 지상 수신기와 항공기 탑재 송신기 간의 장거리 통신시험을 통해 UHF 대역의 전파 수신세기를 측정하고 그 결과를 분석하였다. 지상 수신기는 제주도 해발 1,100m 지점에 위치시키고 항공 탑재 송신기는 지상 수신기로부터 150km에서 220km 거리를 3.5km 이상의 고도로 비행하며 시험을 수행하였다. 이 경우 지상 수신기와 항공 송신기는 가시선(LOS ; Line of Sight)이 확보되는 환경이므로 자유공간손실(FSL ; Free Space Loss)을 토대로 결과를 예측하고 분석을 하는 경우가 일반적이다. 하지만 본 시험의 경우 지상 수신기와 항공 송신기 사이에 해수면이 존재하고, 장거리 통신 환경으로 인하여 반사면에 대한 입사각이 매우 작은 조건으로 직접 파의 자유공간손실 만으로는 정확한 예측 및 분석이 불가능하다. 따라서 주변에 장애물이 없고 두 안테나 사이 가시선이 확보되는 조건을 고려하여 평면 반사 모델과 구면 대지 반사 모델을 토대로 경로 손실을 예측하고 실제 시험결과와 비교하였다. 비교 결과, 구면 대지 반사모델에서 예측한 전파경로 손실 값과 실제 측정결과가 매우 유사한 특성을 보였다.

UHF 대역 수동형 RFID 태그 쇼트키 다이오드 특성 분석 및 전압체배기 설계 (Characterization of Schottky Diodes and Design of Voltage Multiplier for UHF-band Passive RFID Transponder)

  • 이종욱;트란난
    • 대한전자공학회논문지SD
    • /
    • 제44권7호통권361호
    • /
    • pp.9-15
    • /
    • 2007
  • 본 논문에서는 UHF 대역 수동 RFID 태그(UHF-band passive RFID tag) 칩 제작에 필수적인 요소인 쇼트키(Schottky) 다이오드를 CMOS 공정으로 제작하고 크기에 따른 특성을 분석하였으며 이를 이용하여 전압체배기를 설계하였다. 쇼트키 다이오드는 Titanium-Silicon 접합을 이용하여 제작되었으며, $4{\times}10{\times}10\;{\mu}m^{2}$의 면적을 가지는 쇼트키 다이오드는 $20\;{\mu}A$의 전류 구동에 대해 약 0.15 V의 순방향 전압 강하의 우수한 특성을 나타내었다. 역방향 파괴전압(breakdown)은 약 -9 V로 수동 RFID 태그칩의 전압체배기에 사용될 수 있는 충분한 값을 나타내었다. 제작된 쇼트키 다이오드의 소신호 등가모델을 이용하여 다이오드의 크기에 따른 순방향 전압강하와 입력 임피던스간의 trade-off에 대해 분석하였다. 이를 이용하여 제작된 6-단 전압체배기는 900 MHz 주파수, 200mV 최대 입력 전압에 대해 1.3 V이상의 출력 전압 특성을 나타내어 인식거리가 비교적 큰 수동형 태그에 적합한 특성을 나타내었다.