Empirical modelling of chemically enhanced backwash during ultrafiltration process

  • Daramola, M.O.;Adeogun, A.G.
    • Membrane and Water Treatment
    • /
    • v.2 no.4
    • /
    • pp.225-237
    • /
    • 2011
  • In this study, response of reversibility of membrane flux during chemically enhanced backwash (CEB) to changes in filtration time, filtration flux and coagulant concentration dosing during ultrafiltration (UF) process was investigated using a regression model. The model was developed via empirical modelling approach using response surface methodology. In developing the model, statistically designed UF experiments were conducted and the results compared with the model output. The results showed that the performance of CEB, evaluated in terms of the reversibility of the membrane flux, depends strongly on the changes in coagulant concentration dosage and the filtration flux. Also the response of the reversibility of membrane flux during CEB is independent of the filtration time. The variance ratio, VR << $F_{value}$ and $R^2$ = 0.98 obtained from the cross-validation experiments indicate perfect agreement of the model output with experimental results and also testify to the validity and suitability of the model to predict reversibility of the membrane flux during CEB in UF operation.

A Study on Effect of Jet Mixed Separator Combination for Pre-treatment of Ultrafiltration Membrane Filtration Process (UF 막 여과 공정의 효과적인 전처리 공정으로 분류교반고액분리조(噴流攪拌固液分離槽) (Jet Mixed Separator: JMS) 도입 효과에 관한 연구)

  • Lee, Sanghyup;Jang, Nakyong;Watanabe, Yoshimasa
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.38-46
    • /
    • 2005
  • In this research, we tried to combine the coagulation/sedimentation process as pre-treatment with UF membrane filtration to reduce the membrane fouling and to improve the permeate water quality. We used the Jet Mixed Separator (JMS) as coagulation/sedimentation process. We observed that the HPC and E.Coli can't be removed through the direct UF memebrane filtation of surface water. The removal efficiency of dissolved organic substances, indicated by E260 and DOC, was 40% and 15%, respectively. However, the removal efficiency of it increased two time as a result of combination of JMS process as coagulation/sedimentation pre-treatment. This was resulted from the formation of high molecular humic micro-floc through JMS process. The accumulation amount of irreversible cake layer which was not removed by backwashing was less than direct UF membrane filtration of surface water. Moreover, the loading rate of fouling induced substances, such as humic substances and suspended substances, on membrane surface decreased drastically through JMS process. As a result, the accumulation amount of irreversible cake on membrane surface was decreased.

Optimization of Ultrafiltration Process using $MIEX^{(R)}$+Coagulation Process ($MIEX^{(R)}$+응집공정을 이용한 한외여과 공정의 최적화 : 다양한 전처리 공정의 적용에 따른 막 오염 현상 규명)

  • Son, Hee-Jong;Hwang, Young-Do;Roh, Jae-Soon;Jung, Chul-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.753-761
    • /
    • 2005
  • In this study, pretreatment of organic matters with $MIEX^{(R)}$ was evaluated using bench-scale experimental procedures on four organic matters to determine its effect on subsequent UF membrane filtration. For comparison, coagulation process was also used as a pretreatment of UF membrane filtration. Moreover, the membrane fouling potential was identified using different fractions and molecular weights of organic matters. From the removal property of MW organic matters by coagulation process for the sample water NOM and AOM, the removal efficiency of high MW organic matters were much higher than those of low MW organic matters. It was shown that the removal efficiency of high MW organic matter more than 10 kDa was lower than that of low MW organic matter for $MIEX^{(R)}$ process. For the change of permeate flux by the pretreatment process, $MIEX^{(R)}$+UF process showed high removal efficiency of organic matter as compared with coagulation-UF processes, but high reduction rate of permeate flux was presented through the reduction of removal efficiency of high MW organic matter. From sequential filtration test results in order to examine the effect of MW of organic matter on membrane fouling, it was found that the membrane foulant was occurred by high MW organic matter, and the DOC of organic matter less than 0.5 mg/L was working as the membrane foulant. In the case of sample water composed of low MW organic matter less than 10 kDa, since the low MW organic matter less than 10 kDa has high removal efficiency by $MIEX^{(R)}$, low reduction rate of permeate flux is obtained as compared with coagulation-UF processes. In summary, it is required to conduct the research on physical/chemical characteristic of original water before pretreatment process of membrane process is selected, and a pertinent pre-treatment process should be employed based on the physical/chemical characteristic of original water.

Removal of Virus in Home Drinking Water Treatment Systems (가정용 정수시스템의 바이러스 제거)

  • 김영진;오남순;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.45-48
    • /
    • 2000
  • Reverse osmosis filtration(RO) system and ultrafiltration(UF) system are principally use for domestic home drinking water treatment systems. The object of this study is to make a comparison between two systems in terms of theirs abilities to remove RNA coilphage QB as an indicator of pathogenic enteroviruses. The virus removal ratio of RO system was 99.999%, which was higher than EPA virus treatment guideline(99.99%). In the course of filtration, removal ratios of sediment filter, pre-carbon filter, reverse osmosis membrane and post-carbon filter were 75.000%, 93.208%, 99.997% and 99.999%, repectively. In case of UF system, virus removal ratio was 99.708%. Removal ratios of sediment filter, pre-carbon filter, post-carbon filter and ultrafiltration membration membrane were 71.038%, 91.530%, 98.283% and 99.708%, respecively, in UF steps. Therefore, RO system is more effective than UF system in virus removal.

  • PDF

Ultra- and Nano-Filtration Process Optimization of Isoflavones and Oligosaccharides from Sunmul

  • Kim, Woo-Jung;Kim, Hak-Hyun;Yoo, Sang-Ho
    • Food Science and Biotechnology
    • /
    • v.14 no.3
    • /
    • pp.380-386
    • /
    • 2005
  • Optimal conditions of ultrafiltration (UF) and nanofiltration (NF) were investigated for separation and concentration of isoflavones and oligosaccharides from Sunmul. Levels of COD, BOD, and suspended solids (SS) in UF and NF permeates were also determined to evaluate effectiveness of these processes for reducing water pollution. Optimal UF operation conditions to achieve minimal fouling and maximal flux were $33-34^{\circ}C$ operating temperature and 2.3-2.4 bar trans-membrane pressure. Recovery yields of isoflavones and oligosaccharides in UF retentate were 11.49-28.16% and 12.77-27.57%, respectively. Increase in volumetric concentration factor (VCF) resulted in more functional compounds of isoflavones and oligosaccharides passing through UF membrane. Total isoflavone and oligosaccharide yields decreased by 3% as VCF increased from 6.0 to 8.0 and from 8.0 to 10.0, while decreased significantly by 10% as VCF decreased from 4.0 to 6.0. Optimal NF operating conditions were 192-195 psig operating pressure at $30-33^{\circ}C$. Total yields of isoflavones and oligosaccharides significantly decreased at VCF 8.0, whereas did not decrease up to VCF 6.0 during NF operation. Therefore, VCF 6.0 was recommended for economical process. COD and BOD decreased by more than 98% after NF process, and SS were not detected after UF process. These results indicated sequential filtration process was useful for separation of isoflavones and oligosaccharides from Sunmul and for reducing water contaminants.

Treatment Characteristics of Sand Filtration and Microfiltration (MF) in Advanced Water Treatment (고도정수처리에서 사여과와 정밀여과의 유기물처리특성에 관한 연구)

  • Kim, Hyung-Suk;Lee, Byoung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.723-734
    • /
    • 2010
  • With a belief of high water quality production and less chemical usage, membrane technology including Microfiltration (MF), Ultrafiltration (UF), and Nanofiltration(NF) is being employed more and more in drinking water treatment process. However, due to higher energy consumption of UF and NF, MF is normally used for drinking water treatment especially in a plant of large scale. In this investigation, performance ofsand filtration and membrane filtration was compared regarding removal of various water quality parameters, such as TOC, DOC, KMnO4 consumption, THMFP, and HAAFP. Two lines of pilot plant have been operated, one of which line is a traditional advanced water treatment process which includes sedimentation, sand filtration, ozonation, and activated carbon, and the other line is an alternative treatment process which includes sedimentation with inclined plate, MF membrane, ozonation, and activated carbon. For the first about 4months of period, MF filtration showed similar or little bit higher performance than sand filtration. However, after about 4month later, sand filtration showed much higher performance in removing all parameters monitored in the investigation. It was found that sand filtration is a better option than MF filtration as far as microbial community is fully activated in sand filter bed.

막분리(NF, UF)를 이용한 자연유기물(NOM) 제거에 관한 연구(II) - NF, UF 운전특성과 HAA생성능 제거 -

  • Song, Yang-Seok;Park, Yong-Hun;Jo, Yeong-Gwan;Jo, Jae-Won;Park, Don-Hui
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.334-338
    • /
    • 2003
  • In this study, We evaluated the removal efficiency of natural organic matters(NOM) in the Ultrafiltration(UF) and Nanofiltration(NF) membranes with molecular weight cutoff of 2500(GH), 8000(GM) and 250(HL), respectively. Filtration type was cross-flow filtration. The investigation result about raw water structure was hydrophobic 28%, hydrophilic 53% and transphilic 19%, in conjunction with XAD8/4 resin fractionation method. We were compared with UF(GM, GH) and NF(HL), in operation characteristic. In spite of poor MWCO, GM(8000Da) was superior than GH(2500Da), in the efficiency of total operation. It was showed the NF(HL) 80%, UF(GM) 50%, in the removing efficiency of HAAFP.

  • PDF

Fouling characteristics of humic substances on tight polysulfone-based ultrafiltration membrane

  • Ariono, Danu;Aryanti, Putu T.P.;Wardani, Anita K.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.353-361
    • /
    • 2018
  • Fouling characteristics of humic substances on tight ultrafiltration (UF) membrane have been investigated. The tight UF membrane was prepared by blending polysulfone (PSf) in N.N-dimethylacetamide (DMAc) with 25%wt of Polyethylene glycol (PEG400) and 4%wt of acetone. Fouling characteristic of the modified PSf membrane was observed during peat water filtration in different trans-membrane pressure (TMP). It was found that the acetone modified membrane provided 13% increase in TMP during five hours of peat water filtration, where a stable flux was reached within 150 minutes. Meanwhile, the increase of TMP from 10 psig to 30 psig resulted in a fouling resistance enhancement of 60%. Furthermore, based on the fouling analysis, fouling mechanism at the first phase of filtration was attributed to intermediate blocking while the second phase was cake formation.

A Pilot-Scale Microfiltration/Ultrafiltration system for Drinking Water Treatment (상수처리를 위한 파일롯 규모의 정밀여과/한외여과 시스템)

  • Kim, Hanseung;Oh, Jeongik;Kim, Chunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.770-777
    • /
    • 2004
  • Three pilot-scale membrane systems were operated using lake water as influent in this study. Microfiltration (MF) membrane with pore size of 0.01 m was used in Systen I of which filtration mode was set at constant pressure of $1kgf/cm^2$. Ultrafiltration (UF) membranes with molecular cutoff (MWCO) of 80,000 and 13,000 were used in System II-1 and II-2, respectively. Constant flow mode was applied at the range between 0.7 and $1.5m^3/m^2{\cdot}d$ (average of $1.1m^3/m^2${\cdot}d) for System II-1 and between 0.37 and $1.65m^3/m^2{\cdot}d$ (average of $1.18m^3/m^2{\cdot}d$) for System II-2. In System I, the flux changed from $1m^3/m^2{\cdot}d$ to $0.2m^3/m^2{\cdot}d$ during the operation time of 5 months. System II showed recovery of 94% under the allowable maximum pressure of $3kgf/cm^2$ during the same operation period. From these results, the efficient operation was observed in constant flow mode with respect to filtration time and recovery. Average filtrate turbidity showed 0.0071 NTU in System I and 0.0054 NTU in System II, which implied that high turbidity removal was obtained in both MF and UF systems with no significant difference between MF and UF. From the fact that membrane flux depends largely on membrane type and operation mode, a guideline of optimum design and operation should be suggested for application of membrane systems to full scale water treatment.

Application in Ultrafiltration and Reverse Osmosis Module Set with Acrylic Wastewater Pretreated by Coagulation-Filtration-Neutralization Process (응집-여과-중화 공정에 의해 전처리된 아크릴 폐수의 한외여과와 역삼투 모듈 조합 공정에의 적용)

  • Lee, Kwang-Hyun;Kang, Byung-Chul;Lee, Jong-Baek
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • After membrane fouling factors in acrylic wastewater were minimized by pretreatment process accompanied with coagulation-filtration-neutralization, it was utilized in UF/RO process. After composing of ultrafiltration and reverse osmosis module set according to types and kinds of membrane, the separation characteristics were examined with the variation temperature and pressure using pretreated acrylic wastewater by membrane module sets. It was found that permeate flux of UF module in module set 4 was about two${\sim}$three times larger than that of UF module in module set 1. Final quantity of permeate from the module set 2 and module set 3 combined with tubular module was shown very good result. It was shown that the removal efficiency of TDS, T-N and COD was very low and was not dependent on the variation of temperature and pressure in all UF modules. The removal efficiency of TDS, T-N and COD was very excellent in RO module. Final water quality of acrylic wastewater was satisfied with effluent allowances limit and membrane module sets were ascertained to reuse wastewater.