• Title/Summary/Keyword: UDI(Useful daylight illuminance)

Search Result 6, Processing Time 0.024 seconds

Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities (정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가)

  • Choi, Su-Hyun;Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data - (농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Yun, Young Il;Song, Jeong Suk;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

The Study on the Analysis of Useful Daylight Illuminance in Care Facilities - By Dynamic Daylight Simulation Using Weather Data - (요양시설의 유용조도 분석에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로-)

  • Yun, Youngil;Cho, Juyoung;Lee, Hyowon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the care facility design process, because of lack of previous studies on elderly- light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

Trends of Daylight Environment for Office Spaces Based on Smart-Window Installation Settings (스마트 윈도우 설치 속성에 따른 사무공간의 주광 환경 추이)

  • Jae-Hyang Kim;Seung-Hoon Han
    • New & Renewable Energy
    • /
    • v.19 no.3
    • /
    • pp.13-21
    • /
    • 2023
  • Smart windows are capable of varying their visible light transmittance (VLT) in response to changing environmental conditions. The VLT variability of architectural windows is highly valuable because it enables indoor lighting and energy environments to align with external changes. However, challenges such as high installation costs and assurance of glass visibility have prompted the exploration of alternative solutions, including models incorporating partially applied smart windows., Prior research focused on useful daylight illuminance (UDI) analysis for south-facing office buildings, pointing out suitable areas for smart-window implementation to enhance lighting control. In this study, we broadened this scope by determining optimal smart-window application zones under changing building orientation. Furthermore, we studied the correlation between building orientation and smart-window deployment areas.

Evaluation of the daylight performance of adjacent interior spaces in four-sided atrium according to the height ratio of atrium, and the transmittance of atrium canopy (4면형 아트리움의 높이비와 천창 투과율에 따른 인접 실내공간의 자연채광성능 평가)

  • Yu, Ha-Nui;Lee, Ju-Yun;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.57-62
    • /
    • 2010
  • Studies on daylighting of buildings have been continuously increased due to the recent escalating oil price and low-carbon strategies in developed countries. Daylighting of buildings not only saves electric energy, but provide the occupants with a comfort visual environment. Atrium spaces are adopted by many modern buildings to improve daylight performance of deep interior spaces. Among the various types of atria, the four-sided type atrium is frequently adopted by library buildings, governmental buildings and office buildings. This study aims to suggest daylighting design data for adjacent occupied spaces by conducting dynamic simulations using Daysim program. Daylight Factor(DF), Daylight Autonomy(DA) and Useful Daylight Illuminance(UDI) levels for 12 measurement points in adjacent occupied spaces were calculated for square-shape four-sided atria with different SAR(Section Aspect Ratio) and different canopy transmittance.

A Study on the Effect of inflow Daylight according to the installation method of controlling Light Shelf and Blind in the Room of General Hospital (종합병원 병실 내 광선반과 블라인드 설치 방식에 따른 자연채광 유입 효과 연구)

  • Cho, Ju Young;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.3-10
    • /
    • 2013
  • This study aims to identify convenient surrounding of the hospital room to be improved by specifically focusing on light environment and to examine a change of inflow of the daylight in the hospital room by using blind and light shelf device as base data of preliminary research for comprehending the relationship between healing environment and natural day light. Simulation analysis on previous facilities and the installation of horizontal light shelf that derives the inflow of day light has been specifically referred by using ECOTECT2011 program. In case of C-facility that mostly adjoined to exterior spaces, it was shown to be closer to a proper uniformity factor when an angle was controlled on the light shelf with blind installed at the same time. However, it was not overall appropriate because of visual displeasure occurred from inflow of much day light. In conclusion, it is the form of flat surface such as H-facility that provides an effect after installing the device to derive day light. Especially, it was shown that interior day light environment was improved when installing blind and controlling the angle at the same time.