• 제목/요약/키워드: U-loop

검색결과 185건 처리시간 0.022초

Laser Thomson Scattering Measurements and Modelling on the Electron Behavior in a Magnetic Neutral Loop Discharge Plasma

  • Sung, Youl-Moon;Kim, Hee-Je;Park, Chung-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제11C권4호
    • /
    • pp.107-112
    • /
    • 2001
  • Laser Thomson scattering measurements of electrom temperature and density in a neutral loop discharge (NLD) plasma were performed in order to reveal the electron behavior around the neutral loop (NL). The experimental results were examined by using a simulation model that included effects of a three dimensional electromagnetic field with spatial decay of the RF electric field, and the limitation of the spatial extent of the electron motion and collision effect. From the experiments and modeling of the electron behavior, it was found that NLD plasma posses the electron temeprature $T_{e}$ and density ne peaks around the NL is essential for the formation of plasma. Also, the optimum condition of plasma production could be simply estimated by the calculation of $U_{av}$ and $F_{0}$././.

  • PDF

지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향 (Effect of Some Parameters on Ground Effective Thermal Conductivity)

  • 최재호;임효재;공형진;손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.33-38
    • /
    • 2008
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The Size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

SRM 드라이브의 강인한 운전을 위한 PLL 제어 방식 (PLL Control Scheme for Robust Driving of SRM Drive)

  • 오석규;정태욱;박한웅;안진우;황영문
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권9호
    • /
    • pp.461-466
    • /
    • 1999
  • The switched reluctance motor (SRM) would have torque ripple if not operated with an MMF waveform specified for switching angle and phase voltage. This paper describes the robustic control scheme that permits the phase torque to be flat by PLL(Phase Locked Loop) controller. In this control scheme, the locked phase signal of PLL controls the switching dwell angle and it's loop filter signal controls the switching voltage adaptively. Experimental results show that stable dynamic performance is obtained for torque and speed together with low torque ripple on the operation of variable loads.

  • PDF

직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가 (Evaluation of the Annual Performance of the Direct Expansion Vertical Closed-Loop Ground Source Heat Pump)

  • 김민성;우정선;백영진;장재철;김지영;라호상
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.534-542
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As a result, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

  • PDF

주거용 직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가 (Annual Performance Evaluation of Direct Expansion Vertical Closed-Loop Ground Source Heat Pump for Residential Application)

  • 김민성;백영진;라호상
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.114-122
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed -loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As results, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

Bubble Jet Loop Heat Pipe의 유동 가시화 (Flow Visualization of Bubble Jet Loop Heat Pipe)

  • 이현직;공상운;하수정;황종호;장정완;손길재;김종수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.279-283
    • /
    • 2009
  • Bubble jet loop heat pipe is what heat pipe operate in the horizontality. It is consist of one heating part creating bubble and one rounded U tube type radiator. This study shows whether the heat pipe operates well in the horizontality or not, and what optimized refrigerant charging rate is in the tube. But flow visualization of bubble jet heat pipe was not known. The purpose of this study is to visualize bubble jet loop heat pipe. The experiment was performed by changes of charging rate. Working fluid was R-141b. And heater of 220 V & 100 W was used. we take a photograph of flow visualization of bubble jet loop heat pipe in slow motion.

  • PDF

인공위성용 태양전력 조절기의 병렬운전을 위한 전류제어 방식

  • 양정환;박희성;박성우;장진백;이상곤
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.182.1-182.1
    • /
    • 2012
  • 태양전력 조절기는 태양전지에서 전력을 생성하여 배터리를 충전하고 인공위성의 모든 부하에 전력을 공급하는 역할을 한다. 이러한 태양전력 조절기는 신뢰성 확보와 대전류 처리를 위해 병렬운전한다. 병렬운전 시 전류가 각 태양전력 조절기에 균등하게 분배되지 않을 경우, 한 태양전력 조절기에만 과도한 전류가 흐르게 되고 해당 태양전력 조절기에 문제가 발생한다. 따라서 병렬운전 하는 각 태양전지 조절기에 전류를 균등하게 분배하기 위해 전류 제어기가 필요하다. 전류 제어 방식에는 Inner Loop방식과 Outer Loop 방식이 있다. Inner Loop방식은 전류 제어기가 태양전력 조절기의 전류를 제어하고, 전류 제어기의 기준 전압을 외부의 전압 제어기가 제어하는 방식이다. 한편, Outer Loop 방식은 전압 제어기가 태양전력 조절기의 전압을 제어하고, 전압 제어기의 기준 전압에 태양전력 조절기의 전류 정보를 더하여 전압을 제어하면서 간접적으로 전류를 제어하는 방식이다. 한편, 태양전지는 전압과 전류가 강한 비선형성 관계를 가지므로 태양전지의 동작점에 따라 태양전력 조절기의 소신호 특성이 변화하고, 이는 전류제어기 안정도에 심각한 영향을 미친다. 따라서 본 논문에서는 태양전지의 각 동작점에 관계없이 전류 제어기가 안정적으로 태양전력 조절기의 전류분배를 수행할 수 있도록 Inner Loop방식과 Outer Loop방식의 전류 제어기를 해석하고 두 방식을 비교한다.

  • PDF

그라우트 종류와 열교환 파이프 단면에 따른 수직 밀폐형 지중열교환기의 지중 유효열전도도 평가 (Effect of grouts and pipe sections for closed-loop vertical ground heat exchanger on effective ground thermal conductivity)

  • 이철호;박문서;민선홍;강신형;최항석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.167.1-167.1
    • /
    • 2010
  • 본 연구에서는 수직 밀폐형 지중열교환기 뒤채움용 그라우트의 종류와 첨가재 종류, 지중열교환기 파이프 단면에 따른 지중열교환기의 성능을 비교 평가하기 위해 현장 시험 시공과 현장 열응답 시험을 수행하였다. 뒤채움용 그라우트재는 벤토나이트와 시멘트를 사용하였으며 첨가제로는 천연규사와 흑연을 적용하였다. 지중열교환기 파이프 단면은 일반적으로 시공되는 U-loop 파이프 단면과 파이프 사이의 열간섭 효과를 최소화 한 3공형 파이프 단면이 적용되었다. 시멘트-천연규사 그라우트재가 벤토나이트-천연규사 그라우트재 보다 큰 지중 유효열전도도를 보이고 흑연을 첨가한 그라우트는 시멘트와 벤토나이트 모두에서 천연규사만 첨가하였을 때 보다 지중 유효열전도도가 높게 나타났다. 3공형 파이프 단면의 경우 단면에 따른 영향을 비교하기 위해 그라우트는 시멘트-천연규사와 벤토나이트-천연규사를 사용하였으며 지중 유효열전도도 측정결과 각각 3.64 W/mK, 3.40 W/mK으로 일반 U-loop 파이프 단면을 사용하였을 때 보다 높게 나타났다.

  • PDF

PWR루프계통에서 냉각재 재고량 및 비응축성 가스의 자연순환에 미치는 영향 (The Effects of Coolant Inventory and Noncondensible Gas on the Natural Circulation in a PWR Loop System)

  • Cha, Jong-Hee;Jin, Yong-Suk
    • Nuclear Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.308-320
    • /
    • 1989
  • 이 연구는 PWR를 모의한 2루프장치에서 1차냉각재의 재고량 및 비응축성가스가 단상 및 이상 자연순환에 미치는 영향을 실험적으로 조사하고져 한 것이다. 실험장치는 U튜브를 가진 2개의 열교환기로 구성되었다. 일련의 실험을 통하여 다음 사실을 확인하였다. 이상 자연순환의 유량은 1차 냉각재 재고량의 크기에 크게 의존한다. 본 실험에서는 이상 자연순환을 유지하기 위해서는 1차 냉각재 재고량의 수위가 노즐 중심선을 유지해야 함을 알게 되었다. 비응축성 가스의 존재는 단상 자연순환을 정지시킬 수 있으며 그러나 이상 자연순환에는 큰 영향을 주지 않는다.

  • PDF

Influence of connection detailing on the performance of wall-to-wall vertical connections under cyclic loading

  • Hemamalini, S.;Vidjeapriya, R.
    • Advances in concrete construction
    • /
    • 제9권5호
    • /
    • pp.437-448
    • /
    • 2020
  • In high rise buildings that utilize precast large panel system for construction, the shear wall provides strength and stiffness during earthquakes. The performance of a wall panel system depends mainly on the type of connection used to transfer the forces from one wall element to another wall element. This paper presents an experimental investigation on different types of construction detailing of the precast wall to wall vertical connections under reverse cyclic loading. One of the commonly used connections in India to connect wall to wall panel is the loop bar connection. Hence for this study, three types of wet connections and one type of dry connection namely: Staggered loop bar connection, Equally spaced loop bar connection, U-Hook connection, and Channel connection respectively were used to connect the precast walls. One third scale model of the wall was used for this study. The main objective of the experimental work is to evaluate the performance of the wall to wall connections in terms of hysteretic behaviour, ultimate load carrying capacity, energy dissipation capacity, stiffness degradation, ductility, viscous damping ratio, and crack pattern. All the connections exhibited similar load carrying capacity. The U-Hook connection exhibited higher ductility and energy dissipation when compared to the other three connections.