• Title/Summary/Keyword: U-loop

Search Result 185, Processing Time 0.02 seconds

A Study on the Characteristics of Traffic Accidents on Trumpet IC Ramp (트럼펫 IC형식 연결로 교통사고 특성분석에 관한 연구)

  • Yun, Byeong-Jo;O, Yeong-Tae;Lee, Seung-Hwan;Ji, Dong-Han
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.7 s.93
    • /
    • pp.41-51
    • /
    • 2006
  • In this paper, a fundamental study on the characteristics of traffic accidents according to the alignment and traffic conditions on the ramp of freeway is addressed. The macro-and-micro scope analysis of characteristics about traffic accidents on the trumpet-IC ramps is conducted depending on the entering and exit ramp types under the various conditions of traffic volume and alignment And it is turned out that the conditions of alignment. such as radius, differences of curvatures, and main road grade, and traffic volume relate to the ramp accidents of trumpet IC according to ramp types, such as direction, semi-direction, and loop. Macroscopically, AR (Accident Rate) according to trumpet IC types, A and B, is analyzed nearly equal, but Number of accidents occurred in IC type B shows about 1.5 times higher than type A. And AR of exit ramps shows three times more than entrance ramps. Microscopically, ARs for each exit-ramp type, according to the increment of traffic volume, the difference of curvatures. and the first radius, exponentially decrease respectively. But relationships between AR and the second radius or exit ramp shows inverted U-shaped. AR according to main-road grade Peaks between -1.5% and -0.5%. It is expected that the developed models not only are employed to make design of trumpet-IC ramp more cost-efficiently and safely, but also contribute to making alternatives to the reduction of traffic accidents on trumpet IC ramps under the conditions of high traffic accident rate.

The implementation of Korean adult's optimal formant setting by Praat scripting (성인 포먼트 측정에서의 최적 세팅 구현: Praat software와 관련하여)

  • Park, Jiyeon;Seong, Cheoljae
    • Phonetics and Speech Sciences
    • /
    • v.11 no.4
    • /
    • pp.97-108
    • /
    • 2019
  • An automated Praat script was implemented to measure optimal formant frequencies for adults. Optimal formant analysis could be interpreted to show that the deviation of formant frequency that resulted from the two variously combined setting parameters (maximum formant and number of formants) was minimal. To increase the reliability of formant analysis, LPC order should be set differently, based on the gender or vowel type. Praat recommends 5,000 Hz and 5,500 Hz as maximum formant settings and, at the same time, recommends 5 as the number of formants for males and females. However, verification is needed to determine whether these recommended settings are valid for Korean vowels. Statistical analysis showed that formant frequencies significantly varied across the adapted scripts, especially with respect to the data on females. Formant plots and statistical results showed that linear_script and qtone_script are much more reliable in formant measurements. Among four kinds of scripts, the linear and qtone_scripts proved to be more stable and reliable. While the linear_script was designed to have a linearly increased formant step in for-loop, the increment of formant step in the qtone_script was arranged by quarter tone scale (base frequency×common ratio ($\sqrt[24]{2}$)). When looking at the tendency of the formant setting drawn by the two referred algorithms in the context of front vowel [i, e], the maximum formant was set higher; and the number of formants set at a lower value than recommended by Praat. The back vowel [o, u], on the contrary, has a lower maximum formant and a higher number of formants than the standard setting.

Knockdown of HMGN5 Expression by RNA Interference Induces Cell Cycle Arrest in Human Lung Cancer Cells

  • Chen, Peng;Wang, Xiu-Li;Ma, Zhong-Sen;Xu, Zhong;Jia, Bo;Ren, Jin;Hu, Yu-Xin;Zhang, Qing-Hua;Ma, Tian-Gang;Yan, Bing-Di;Yan, Qing-Zhu;Li, Yan-Lei;Li, Zhen;Yu, Jin-Yan;Gao, Rong;Fan, Na;Li, Bo;Yang, Jun-Ling
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.7
    • /
    • pp.3223-3228
    • /
    • 2012
  • HMGN5 is a typical member of the HMGN (high mobility group nucleosome-binding protein) family which may function as a nucleosomal binding and transcriptional activating protein. Overexpression of HMGN5 has been observed in several human tumors but its role in tumorigenesis has not been fully clarified. To investigate its significance for human lung cancer progression, we successfully constructed a shRNA expression lentiviral vector in which sense and antisense sequences targeting the human HMGN5 were linked with a 9-nucleotide loop. Inhibitory effects of siRNA on endogenous HMGN5 gene expression and protein synthesis were demonstrated via real-time RT-PCR and western blotting. We found HMGN5 silencing to significantly inhibit A549 and H1299 cell proliferation assessed by MTT, BrdU incorporation and colony formation assays. Furthermore, flow cytometry analysis showed that specific knockdown of HMGN5 slowed down the cell cycle at the G0/G1 phase and decreased the populations of A549 and H1299 cells at the S and G2/M phases. Taken together, these results suggest that HMGN5 is directly involved in regulation cell proliferation in A549 and H1299 cells by influencing signaling pathways involved in cell cycle progression. Thus, our finding suggests that targeting HMGN5 may be an effective strategy for human lung cancer treatment.

High Temperature Application of Iron Removal Chemical Cleaning Solvent in the Secondary Side of Nuclear Steam Generators (증기발생기 2차측 제철화학세정액의 고온적용)

  • Hur, D.H.;Lee, E.H.;Chung, H.S.;Kim, U.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.140-148
    • /
    • 1994
  • A qualification test was performed for the iron removal chemical cleaning of the secondary side of nuclear steam generators at the selected temperature, 1$25^{\circ}C$, higher than the standard application temperature, 93$^{\circ}C$. The field cleaning condition for a nuclear unit was tested in a bench scale test loop including a SUS 316 stainless steel autoclave with one gallon capacity as a test vessel. The kinetics of sludge dissolution, corrosion of the secondary side materials and change of solvent chemistry were monitored. Test results indicated that more thorough cleaning was accomplished in less than half of the cleaning time required at 93$^{\circ}C$. And the total corrosions of the secondary side materials were found to be less than the values at 93$^{\circ}C$. While the solvent is recirculated and heated by an external chemical cleaning equipment for the conventional 93$^{\circ}C$ process, the secondary side is heated by the lateral heat of the primary coolant without the recirculation of the cleaning solution, and the solvent is mixed by vigorous boiling induced by periodic ventilation for the high temperature process. The requirement that the reactor coolant pumps should be running during the cleaning operation is the major disadvantage of the high temperature process which also should be considered when chemical cleaning is planned for steam generators under operation.

  • PDF

Anorectal Malformations In Korea - A Clinical Survey by the Korean Association of Pediatric Surgeons, 1999 - (한국의 항문-직장 기형 -1999년도 대한소아외과학회 회원 대상 전국 조사-)

  • Lee, M.D.;Kim, S.Y.;Kim, W.K.;Kim, I.K.;Kim, J.U.;Kim, J.C.;Kim, H.H.;Park, K.W.;Park, W.H.;Song, Y.T.;Oh, S.M.;Yoo, S.Y.;Lee, D.S.;Lee, S.K.;Lee, S.C.;Chang, S.I.;Chung, S.Y.;Jung, S.E.;Chung, U.S.;Jung, P.M.
    • Advances in pediatric surgery
    • /
    • v.6 no.2
    • /
    • pp.106-123
    • /
    • 2000
  • The purpose of the survey was to clarify the clinical features and management of the anorectal malformations (ARM) in Korea. Twenty-seven members of the Korean Association of Pediatric Surgeons were surveyed. The members completed a case registration form for each patient during the two years period of 1996-1997, and a questionnaire that contained their management preferences for primary and complicated patients. Twenty-four members of the 22 institutions registered 295 cases of the ARM, and 27 out of 34 members (77.1 %) responded to the questionnaire. The patients were classified by the Wingspread classification of ARM(1984). The case registration form was a modification of Wingspread workshop for the postoperative assessment and case registration. The male to female ratio was 1.7 : 1. The average number of patients per surgeon was 6.1 cases per year. Prematurity(< 36 weeks) was present in 1.9 % of cases and low birth weight (< 2.6 Kg) in 12.1 %. Among 187 male patients, 62 were high(H) type, 29 intermediate(l) type, 88 low(L), and 8 unclassified. In female, there were 2 cases of cloacal anomalies(C), 4 H type, 30 I type, 66 L type and 6 unclass ified. For male, 87.9 % of H and I type were operated by the Pena procedure, but only 7.9 % in L types. In female, all of C, H and I types, and 40.9 % of L type were done by the Pena procedure. One case expired (MR; 0.003%) as a result of surgical complication. Over-all complication rate was 12.5 %. Among 6 cases of reoperation, 4 were failed Pena procedures. Among 140 colostomies sigmoid colon was utilized in 75.7%, and loop colostomy was commonly used. Ten surgeons prefered primary maturation of the stoma. In conclusion, posterior sagittal anorectoplasty is popular for high types of ARM in this country, but considerable number of patients are still suffering from failed operations. For better understanding and analysis, necessity of prospective study by new classification was discussed.

  • PDF