• Title/Summary/Keyword: U-Tube

Search Result 386, Processing Time 0.023 seconds

Preconditioned Jacobian-free Newton-Krylov fully implicit high order WENO schemes and flux limiter methods for two-phase flow models

  • Zhou, Xiafeng;Zhong, Changming;Li, Zhongchun;Li, Fu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.49-60
    • /
    • 2022
  • Motivated by the high-resolution properties of high-order Weighted Essentially Non-Oscillatory (WENO) and flux limiter (FL) for steep-gradient problems and the robust convergence of Jacobian-free Newton-Krylov (JFNK) methods for nonlinear systems, the preconditioned JFNK fully implicit high-order WENO and FL schemes are proposed to solve the transient two-phase two-fluid models. Specially, the second-order fully-implicit BDF2 is used for the temporal operator and then the third-order WENO schemes and various flux limiters can be adopted to discrete the spatial operator. For the sake of the generalization of the finite-difference-based preconditioning acceleration methods and the excellent convergence to solve the complicated and various operational conditions, the random vector instead of the initial condition is skillfully chosen as the solving variables to obtain better sparsity pattern or more positions of non-zero elements in this paper. Finally, the WENO_JFNK and FL_JFNK codes are developed and then the two-phase steep-gradient problem, phase appearance/disappearance problem, U-tube problem and linear advection problem are tested to analyze the convergence, computational cost and efficiency in detailed. Numerical results show that WENO_JFNK and FL_JFNK can significantly reduce numerical diffusion and obtain better solutions than traditional methods. WENO_JFNK gives more stable and accurate solutions than FL_JFNK for the test problems and the proposed finite-difference-based preconditioning acceleration methods based on the random vector can significantly improve the convergence speed and efficiency.

Analysis on Hypothetical Multiple Events of mSGTR and SBO at CANDU-6 Plants Using MARS-KS Code (중수로 원전 가상의 mSGTR과 SBO 다중 사건에 대한 MARS-KS 코드 분석)

  • Seon Oh YU;Kyung Won LEE;Kyung Lok BAEK;Manwoong KIM
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.18-27
    • /
    • 2021
  • This study aims to develop an improved evaluation technology for assessing CANDU-6 safety. For this purpose, the multiple steam generator tube rupture (mSGTR) followed by an unmitigated station blackout (SBO) in a CANDU-6 plant was selected as a hypothetical event scenario and the analysis model to evaluate the plant responses was envisioned into the MARS-KS input model. The model includes logic models for controlling the pressure and inventory of the primary heat transport system (PHTS) decreasing due to the u-tubes' rupture, as well as the main features of PHTS with a simplified model for the horizontal fuel channels, the secondary heat transport system including the shell side of steam generators, feedwater and main steam line, and moderator system. A steady state condition was successfully achieved to confirm the stable convergence of the key parameters. Until the turbine trip, the fuel channels were adequately cooled by forced circulation of coolant and supply of main feedwater. However, due to the continuous reduction of PHTS pressure and inventory, the reactor and turbine were shut down and the thermal-hydraulic behaviors between intact and broken loops got asymmetric. Furthermore, as the conditions of low-flow coolant and high void fraction in the broken loop persisted, leading to degradation of decay heat removal, it was evaluated that the peak cladding temperature (PCT) exceeded the limit criteria for ensuring nuclear fuel integrity. This study is expected to provide the technical bases to the accident management strategy for transient conditions with multiple events.

Impact of Pulmonary Vascular Compliance on the Duration of Pleural Effusion Duration after Extracardiac Fontan Procedure (수술 전 폐혈관 유순도가 심장 외 도판을 이용한 Fontan 수술 후 늑막 삼출 기간에 미치는 영향)

  • Yun Tae-Jin;Im Yu-Mi;Song Kwang-Jae;Jung Sung-Ho;Park Jeong-Jun;Seo Dong-Man;Lee Moo-Song
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.579-587
    • /
    • 2006
  • Background: Preoperative risk analysis for Fontan candidates is still less than optimal in that patients with apparently low risks may have poor surgical outcome; prolonged pleural drainage, protein losing enteropathy, pulmonary thromboembolism and death. We hypothesized that low pulmonary vascular compliance (PVC) is a risk factor for prolonged pleural effusion drainage after the Fontan operation. Material and Method: A retrospective review of 96 consecutive patients who underwent the Extracardiac Fontan procedures (median age: 3.9 years) was performed. Fontan risk score (FRS) was calculated from 12 categorized preoperative anatomic and physiologic variables. PVC $(mm^2/m^2{\cdot}mmHg)$ was defined as pulmonary artery index $(mm^2/m^2)$ divided by total pulmonary resistance $(W.U{\cdot}/m^2)$ and pulmonary blood flow $(L/min/m^2)$ based on the electrical circuit analogue of the pulmonary circulation. Chest tube indwelling time was log-transformed (log indwelling time, LIT) to fit normal distribution, and the relationship between preoperative predictors and LIT was analyzed by multiple linear regression. Result: Preoperative PVC, chest tube indwelling time and LIT ranged from 6 to 94.8 $mm^2/mmHg/m^2$ (median: 24.8), 3 to 268 days (median: 20 days), and 1.1 to 5.6 (mean: 2.9, standard deviation: 0.8), respectively. FRS, PVC, cardiopulmonary bypass time (CPB) and central venous pressure at postoperative 12 hours were correlated with LIT by univariable analyses. By multiple linear regression, PVC (p=0.0018) and CPB (p=0.0024) independently predicted LIT, explaining 21.7% of the variation. The regression equation was LIT=2.74-0.0158 PVC+0.00658 CPB. Conclusion: Low pulmonary vascular compliance is an important risk factor for prolonged pleural effusion drainage after the extracardiac Fontan procedure.

Video-assisted Talc Poudrage for the Treatment of Malignant Pleural Effusion: Analysis of Effects and Benefits (악성 늑막 삼출증에서의 비디오 흉강경하 탈크 분무의 효과 및 장점 분석)

  • Song, In-Hag;Chang, Won-Ho;Choi, Chang-Woo;Son, Jin-Sung;Kim, Dong-Hyun;Baek, Kang-Seok;Youm, Wook;Kim, Hyun-Jo
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.492-498
    • /
    • 2007
  • Background: Malignant pleural effusion is a common condition in neoplastic patients and palliative therapy is the usual treatment. Talc has been generally accepted to be the most effective sclerosant for chemical pleurodesis, but the optimal route of administration remains controversy. We compared the results of video-assisted thoracoscopic talc poudrage (VTP) with administering a bedside talc slurry through a chest tube (BTS) for the treatment of malignant pleural effusion. Material and Method: From December 2004 to May 2006, 20 patients with malignant pleural effusion underwent chemical pleurodesis via VTP (group A, n=10), and BTS (group B, n=10). Result: The durations of chest tube placement after the procedure were $7.0{\pm}4.0$ days (group A) and $6.7{\pm}3.6$ days (group B). The hospital stays were $24.3{\pm}9.4$ days (group A) and $30.7{\pm}21.5$ days (group B), respectively. The symptoms of dyspnea were much more improved in group A (p-value=0.014) after discharge (mean f/u group $A=8.5{\pm}2.2$ months, group B $8.0{\pm}7.4$ months). The collapsed portions of lung were better expanded in group A than in group B (p-value=0.011). Conclusion: We recommend VTP for the selected patients with malignant pleural effusion because of the advantages of dissecting the fibrous peel to relieve the atelectasis and dyspnea, and excising the pleura for diagnosis with direct viewing of the lesion.

Effects of Intracavitary Urokinase Instillation in Complicated Pleural Effusion (합병성 흉막 삼출에 대한 국소적 Urokinase 주입치료 효과에 관한 연구)

  • Sohn, Dong-Hyun;Yoon, Su-Mi;Kim, Chung-Mi;Park, Ik-Soo;Sohn, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.3
    • /
    • pp.357-364
    • /
    • 2000
  • Background : Complicated exudative pleural fluid collections have traditionally been treated by either closed tube thoracostomy drainage or by open surgical drainage. Complete drainage is important in order to control pleural sepsis, restore pulmonary function, and entrapment. Recently intracavitary fibrinolytic therapy has been advocated as a method to facillitate drainage of complicated exudative pleural effusion and to allow enzymatic debridemant of the restrictive fibrinous sheets covering the pleural surface. The purpose of this study is to prospectively evaluate the effects of image-guided catheter drainage with high dose urokinase(UK) instillation in the treatment of complicated pleural effusions. Patients : Twenty complicated pleural effusion patients that poorly respond to image-guided drainage were allocated to receive UK. There were 8 pneumonia and 12 tuberculosis. Methods : Drugs were diluted in 250 mL normal saline and were infused intrapleurally through the chest tube or pig-tail catheter in a daily dose of 250,000 IU of UK. Response was assessed by clinical outcome, fluid drainage, chest radiography, pleural ultrasound and/or computed tomography. Results : The mean UK instillation time was $1.63{\pm}0.10$. The mean volume drained UK instillation was $381.3{\pm}314.4\;mL$, and post-UK was $321.6{\pm}489.5\;mL$. The follow up duration after UK therapy was mean $212.9{\pm}194.5$ days. We had successful results in 19 cases (95.0%). There were 12 pleural thickenings (60.0%), 2 markedly decreased effusions (10.0%) and 5 cases of no thickening or effusion. There was recurrence after treatment in only one patient(5%) with complicated pleural effusiondue to tuberculosis. Conclusions : Image-guided drainage with high dose UK instillation (250,000 U/day) in complicated pleural effusion is a safe and more effective method than closed thoracostomy drainage. And this management, in turn, can obviate surgery in most cases.

  • PDF

Protoplast Regeneration, Reversion and Isolation of Auxotrophic Mutants in Flammulina velutipes (팽이버섯 (Flammulina velutipes)원형질체(原形質體)의 재생(再生), 환원(還元) 및 영양요구성(營養要求性) 균주선발(菌株選拔))

  • Shin, Gwan Chull;Park, Jong Seung;Yoo, Young Bok;Yeo, Un Hyung
    • Korean Journal of Agricultural Science
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 1988
  • Factors affecting the regeneration, reversion of protoplasts from mycelium of F. velutipes were investigated and the selection of auxotrophic mutants from protoplasts of F. velutipes was performed. PDP medium stabilized with 0.6M sucrose was suitable for the regeneration of protoplasts, and regeneration frequency was 0.47-1.32. The regeneration frequency of protoplasts was increased when nutrients were added to the regeneration medium. Especially, yeast extract was the most effective to regeneration of protoplasts. Regeneration pattern of protoplasts was formation of germ tubes from bud-like cells. 13-18% of monokaryotic strains was appeared from reverted protoplasts. Five of auxotrophic mutants were isolated from strains showed survival frequency of 1.9-16.

  • PDF

A STUDY ON THE MICROBIAL CONTAMINATION OF DENTAL UNIT AND ULTRASONIC SCALER (덴탈유니트의 핸드피스 및 초음파 치석 제거기의 미생물 오염에 관한 연구)

  • Lee, Byung-Moon;Kim, Chang-Whe;Kim, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.64-80
    • /
    • 1998
  • The risk of cross-contamination in dental clinic is very high. Those who are engaged in dental clinic are exposed to various microorganisms in saliva and blood of patient. Potential possibility of cross-contamination of patient to patient, patient to dentist, dentist to laboratory technician always exist, which is important in the view of public health. It is well known that microorganisms may cause cross-contamination by suck-back of microorganisms into the water supply line or air supply line of dental unit and sprayed back into the next patient's oral cavity. The majority of microorganisms coming from dental unit are water microorganisms from the main water supply which have colonized the tube within the units and multiplied in the relatively warm and stagnant conditions. The purpose of this study is to measure the extent of microbial contamination of dental unit and ultrasonic scaler, to evaluate that dental unit water supply is suitable for drinking water, and to assess the effect of flushing on reduction of microbial contamination of dental unit and ultrasonic scaler. In the first experiment, water samples(50ml) from 20 dental units and 10 ultrasonic scalers in Seoul National Univ. Hosp. were tested for the presence of coliform. The samples were filtered by membrane filtration technique.(Microfil system, Millipore Co. U. S. A.) The filter was then placed onto MacConkey agar plate and the plates with filter on it were incubated aerobically at $37^{\circ}C$ for 5 days. The colors and shapes of colonies were examined if those were coliform. To verify the presence of coliform, the colonies were inoculated into phenol red lactose broth and incubated aerobically at $37^{\circ}C$ for 2 days. The fomation of gas was observed. In the second experiment, water samples from 20 handpieces, 10 ultrasonic scalers and 30 A/W syringes after 0, 2, 4, 6 min. flushing respectively were taken. $200{\mu}l$ water samples were spreaded on Brain Heart Infusion agar plate and the plates were incubated aerobically at $37^{\circ}C$ for 5 days. The number of colony was counted. The results obtained were summarized as follows 1. The water from dental unit and ultrasonic scaler was not suitable for drinking water. 2. No coliform was founded in dental unit and ultrasonic scaler water supply. 3. The number of colony of dental unit and ultrasonic scaler was highest in the group of o min. flushing(p<0.05). 4. There was no statistically significant difference in the extent of microbial contamination among handpiece, ultrasonic scaler and A/W syringe (p>0.05). 5. The number of colony was lowest in the group of 4 min. flushing, but there was no statistically significant difference among 2, 4, 6 min. flushing groups.(p>0.05) 6. It is recommended to flush dental unit water line for 4 min. after use on each patient.

  • PDF

Video Assisted Thoracic Surgery of Spontaneous Pneumothorax (비디오 흉강경을 이용한 자연성 기흉 수술)

  • Ryu, Ji-Yun;Kim, Seung-U;Jo, Gwang-Hyeon
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.512-516
    • /
    • 1997
  • We have experienced 66 cases of video assisted thoracic surgery(VATS) of spontaneous pneumothorax. The patients ranged in age from 1 Syears to 46years(mean age, 22.3years) and male patients were sixty three. The indications of video assisted thoracic surgery of spontaneous pneumothorax were recurrence, continuous air leakage, visible blabs on the chest X-ray & others. Infraoperative findings were as follows; blabs, pleural adhesion and pleural effusion. The operation was performed under general anesthesia wit double lumen endobronchial tube. Operative procedures included blebectomy and/or wedge resection of lung, vibramycin Pleurodesis with mechanical abrasion. In most cases, postoperative courses were uneventful and patients were discharged without significant complications. VATS provided the benefits of lesser postoperative pain, rapid recovery, short hospitalization, and smaller scar of wound. Conclusively VATS is a new interesting modality of surgical treatment of spontaneous pneumothorax and also can be extensively applicable in the diagnosis and treatment of other intrathoracic disease.

  • PDF

브란운관의 후면유리 폐기물을 이용한 제올라이트 합성

  • Jang, Yeong-Nam;Bae, In-Guk;Chae, Su-Cheon;Ryu, Gyeong-Won
    • Journal of the Korean Professional Engineers Association
    • /
    • v.34 no.2
    • /
    • pp.167-173
    • /
    • 2001
  • Through alkaline hydrothermal activation processes, Na-A type zeolite was synthesized as a single phase withfunnel-glass waste from a television tube factory. The autoclaving was performed in a closed teflon vessel in therange of 80~95"C. The silica-rich solution as a starting material was hydrothermally synthesized with quartz in INNaOH by heating 350"C under the pressure of 1,500 atm. NaA102 was made from NaOH and Al(OH)3 by heating95"c for 2~3 hours and the molar ratios of it were Na20/A1203=1.4 and H20Ha20=8. The equi-dimensional Atype zeolite (1 ~2 U) was formed by the simple mixing of'the silica-rich solution, glass waste and NaA102 for I~3hours-heating at 80"C. The characterization of the reaction product shows Na-A as a single phase. The synthesizedzeolite has cube-dodecahedral form and Ca2+ ion exchange capacity of the Na-A was in the range of 215~220mequivalent/100 g.20mequivalent/100 g.

Status of Underground Thermal Energy Storage as Shallow Geothermal Energy (천부 지열에너지로서의 지하 열에너지 저장 기술 동향)

  • Shim, Byoung-Ohan;Lee, Chol-Woo
    • Economic and Environmental Geology
    • /
    • v.43 no.2
    • /
    • pp.197-205
    • /
    • 2010
  • Recently abrupt climate changes have been occurred in global and regional scales and $CO_2$ reduction technologies became an important solution for global warming. As a method of the solution shallow underground thermal energy storage (UTES) has been applied as a reliable technology in most countries developing renewable energy. The geothermal energy system using thermal source of soil, rock, and ground water in aquifer or cavern located in shallow ground is designed based on the concept of thermal energy recovery and storage. UTES technology of Korea is in early stage and consistent researches are demanded to develop environmental friendly, economical and efficient UTES systems. Aquifers in Korea are suitable for various type of ground water source heat pump system. However due to poor understanding and regulations on various UTES high efficient geothermal systems have not been developed. Therefore simple closed U-tube type geothermal heat pump systems account for more than 90% of the total geothermal system installation in Korea. To prevent becoming wide-spread of inefficient systems, UTES systems considering to the hydrogeothemal properties of the ground should be developed and installed. Also international collaboration is necessary, and continuous UTES researches can improve the efficiency of shallow geothermal systems.