• 제목/요약/키워드: U-Shaped Tube

검색결과 19건 처리시간 0.027초

임의형상을 갖는 납작관에서의 혼합대류 열전달 해석 (Analysis of Mixed Convection Heat Transfer in Arbitrarily Shaped Flat Tubes)

  • 박희용;박경우;이상철
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.398-410
    • /
    • 2001
  • The flow and heat transfer characteristics for three-dimensional mixed convection flows in a radiator flat tube with U--shaped grooves are analyzed numerically. The flow and temperature fields are calculated by using the modified SIMPLE algorithm for irregular geometry. One tube specification among the various flat tube exchangers is recommended by considering the heat transfer and pressure drop. The effects of variation of coolant flow conditions and external air conditions on the flow and the thermal characteristics for the selected tube are investigated. the results show that inlet velocity of coolant flow is the very important factor in heat transfer and pressure drop, and top side is better position than the others as fin cleave to tube.

  • PDF

진공튜브 속에서 분해하는 리튬암모니아 솔루션의 열전효율 향상 (Thermoelectric Efficiency Improvement in Vacuum Tubes of Decomposing Liquid Lithium-Ammonia Solutions)

  • 이정윤;김미애;심규철;김지범;전준현
    • Korean Chemical Engineering Research
    • /
    • 제51권3호
    • /
    • pp.358-363
    • /
    • 2013
  • 순수한 리튬-암모니아(Li-$NH_3$) 솔루션의 생성은 진공 상태에서 가능하지만, 고효율 열전전력을 얻기 위한 안정적이고 신뢰성 있는 분해에 대한 문제가 아직 남아있다. 본 논문은 Li-$NH_3$ 솔루션의 열전변환 효율을 향상시키기 위한 새로운 방법을 다루었다. 제안된 방법은 Li-$NH_3$ 솔루션의 합성과 분해를 위해 'U' 형태의 파이렉스 진공 튜브를 사용하였다. 튜브 상부에는 기존 'U' 형태의 파이렉스 진공 튜브의 두 다리를 연결하는 기체의 이동통로가 있는데, 이는 고온부(Hot side)에서 분해가 진행될 때 $NH_3$ 기화에 따른 양단의 내부압력 불균형을 방지하는 역할을 한다. 열전 실험결과, 'U' 형태 튜브 속에서 솔루션 반응은 기존 'U' 형태에 비해 매우 안정적이고 효율적으로 이루어졌으며, 결과적으로 열전변환 효율이 향상됨을 보였다. 또한, 제안 방식은 장시간에 걸친 고효율 열전 발전을 위해 튜브 속에서 합성과 분해가 순환되는 가역반응을 제공함이 입증되었다.

SUS304L 튜브의 U-Bending 성형공정에 관한 해석적·실험적 연구 (Numerical and Experimental Study of U-Bending of SUS304L Heat Transfer Tubes)

  • 김유범;강범수;구태완
    • 소성∙가공
    • /
    • 제23권7호
    • /
    • pp.405-412
    • /
    • 2014
  • As a major type of heat exchanger, the steam generator (SG) produces steam from heat energy of a nuclear power plant reactor. The steam produced by the steam generator flows into a turbine, and plays an important role in electric power generation. The heat transfer tubes in the steam generator consist of approximately 10,000 U-shaped tubes, which perform a structural role and act as thermal boundaries. The heat transfer tubes conduct the thermal energy between the primary coolant (about $320^{\circ}C$, $157kgf/cm^2$) obtained from the reactor and the secondary coolant (about $260^{\circ}C$, $60kgf/cm^2$) as part of the secondary system. Recently, the heat transfer tubes in the steam generator of the pressurized water reactor (PWR) are primarily produced from Alloy 600 and Alloy 690 seamless tubes. As a pilot study to find process parameters for the cold U-bending process using rotary draw bending, numerical and experimental investigations were conducted to produce U-shaped tubes from long straight SUS304L seamless tubes. 3D finite element simulations were run using ABAQUS Explicit with consideration of the elastic recovery. The process parameters studied were the angular speed, the operation period and the bending angle. Experimental verifications were conducted to insure the suitability of the final U-shaped configurations with respect to both ovality and wall thickness.

U자형 배관 내 결빙에 대한 해석적 연구 (Numerical Analysis of Freezing Phenomena of Water in a U-Type Tube)

  • 박용석;서정세
    • 한국기계가공학회지
    • /
    • 제18권12호
    • /
    • pp.52-58
    • /
    • 2019
  • This study numerically analyzed the icing process in a U-shaped pipe exposed to the outside by considering the mushy zone of freezing water. Numerical results showed that the flow was pulled outward due to the U-shaped bend in the freezing section exposed to the outside, which resulted in the ice wave formation on the wall of the bended pipe behind. At the same time, the formation of a corrugated ice layer became apparent due to the venturi effect caused by the ice. The factors affecting the freezing were investigated, including the change of the pipe wall temperature, the water inflow velocity, and the pipe bend spacing. It was found that, as a whole, the thickness of the freezing layer increased as the pipe wall temperature decreased. It was also found that the freezing layer became relatively thin when the inflow rate of water was increased, and that the spacing of the pipe bends did not significantly impact the change in the freezing layer.

The influence of strengthening the hollow steel tube and CFST beams using U-shaped CFRP wrapping scheme

  • Zand, Ahmed W. Al;Hosseinpour, Emad;Badaruzzaman, Wan Hamidon W.
    • Structural Engineering and Mechanics
    • /
    • 제66권2호
    • /
    • pp.229-235
    • /
    • 2018
  • This study investigated the behaviour of the simply supported hollow steel tube (HST) beams, either concrete filled or unfilled when strengthened with carbon fibre reinforced polymer (CFRP) sheets. Eight specimens with varied tubes thickness (sections classification 1 and 3) were all tested experimentally under static flexural loading, four out of eight were filled with normal concrete (CFST beams). Particularly, the partial CFRP strengthening scheme was used, which wrapped the bottom-half of the beams cross-section (U-shaped wrapping), in order to use the efficiency of high tensile strength of CFRP sheets at the tension stress only of simply supported beams. In general, the results showed that the CFRP sheets significantly improved the ultimate strength and energy absorption capacities of the CFST beams with very limited improvement on the related HST beams. For example, the load and energy absorption capacities for the CFST beams (tube section class 1) were increased about 20% and 32.6%, respectively, when partially strengthened with two CFRP layers, and these improvements had increased more (62% and 38%) for the same CFST beams using tube class 3. However, these capacities recorded no much improvement on the related unfilled HST beams when the same CFRP strengthening scheme was adopted.

Low-frequency modes in the fluid-structure interaction of a U-tube model for the steam generator in a PWR

  • Zhang, Hao;Chang, Se-Myong;Kang, Soong-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1008-1016
    • /
    • 2019
  • In the SG (steam generator) of PWR (pressurized water reactor) for a nuclear plant, hundreds of U-shaped tubes are used for the heat exchanger system. They interact with primary pressurized cooling water flow, generating flow-induced vibration in the secondary flow region. A simplified U-tube model is proposed in this study to apply for experiment and its counterpart computation. Using the commercial code, ANSYS-CFX, we first verified the Moody chart, comparing the straight pipe theory with the results derived from CFD (computational fluid dynamics) analysis. Considering the virtual mass of fluid, we computed the major modes with the low natural frequencies through the comparison with impact hammer test, and then investigated the effect of pump flow in the frequency domain using FFT (fast Fourier transform) analysis of the experimental data. Using two-way fluid-structure interaction module in the CFD code, we studied the influence on mean flow rate to generate the displacement data. A feasible CFD method has been setup in this research that could be applied potentially in the field of nuclear thermal-hydraulics.

FLUID-STRUCTURE INTERACTION IN A U-TUBE WITH SURFACE ROUGHNESS AND PRESSURE DROP

  • Gim, Gyun-Ho;Chang, Se-Myoung;Lee, Sinyoung;Jang, Gangwon
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.633-640
    • /
    • 2014
  • In this research, the surface roughness affecting the pressure drop in a pipe used as the steam generator of a PWR was studied. Based on the CFD (Computational Fluid Dynamics) technique using a commercial code named ANSYS-FLUENT, a straight pipe was modeled to obtain the Darcy frictional coefficient, changed with a range of various surface roughness ratios as well as Reynolds numbers. The result is validated by the comparison with a Moody chart to set the appropriate size of grids at the wall for the correct consideration of surface roughness. The pressure drop in a full-scale U-shaped pipe is measured with the same code, correlated with the surface roughness ratio. In the next stage, we studied a reduced scale model of a U-shaped heat pipe with experiment and analysis of the investigation into fluid-structure interaction (FSI). The material of the pipe was cut from the real heat pipe of a material named Inconel 690 alloy, now used in steam generators. The accelerations at the fixed stations on the outer surface of the pipe model are measured in the series of time history, and Fourier transformed to the frequency domain. The natural frequency of three leading modes were traced from the FFT data, and compared with the result of a numerical analysis for unsteady, incompressible flow. The corresponding mode shapes and maximum displacement are obtained numerically from the FSI simulation with the coupling of the commercial codes, ANSYS-FLUENT and TRANSIENT_STRUCTURAL. The primary frequencies for the model system consist of three parts: structural vibration, BPF(blade pass frequency) of pump, and fluid-structure interaction.

소형 코리올리 질량 유량계의 개발 (Development of Small Size Coriolis Mass Flowmeter)

  • 임기원;지정근
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

Reference Values of Whole Blood Viscosity and Its Correlation with Hematology and Serum Chemistry in Beagle Dogs

  • Koh, Jun;Lee, Dong-bin;Lee, Dong Han;Kim, Nam Soo
    • 한국임상수의학회지
    • /
    • 제35권3호
    • /
    • pp.77-82
    • /
    • 2018
  • The aim of this study was to measure whole blood viscosity (WBV) and then to establish its reference values and identify correlation between WBV and hematology or serum chemistry in beagle. The experiment was made up of 82 healthy beagle dogs. Jugular vein blood samples (10 ml) were collected. WBV (cP) measured within 4 hours after collection by U-shaped scanning capillary-tube viscometer ($BVD-PRO1^{(R)}$) which is capable of measuring yield stress and viscosity of whole blood continuously over a wide range of shear rates from $1s^{-1}$ to $1000s^{-1}$ is new type of capillary tube viscometer and calculates viscosity using Casson fluid model. Measured values of WBV, Complete blood cell count, serum chemistry were analyzed by RM-ANOVA test. Mean diastolic and systolic WBV (cP) were $29.032{\pm}6.137$ and $4.528{\pm}0.865$. Bodyweight (BW), Red blood cell count (RBC), Hemoglobin (HGB), Hematocrit (HCT), Alkaline phosphatase (ALP), Cholestetol (CHOL), Total protein (TP), Globulin, Chloride (Cl), Fibrinogen, were statistically correlated with WBV over whole range of shear rates (p < 0.05). This study newly evaluated reference values of WBV by U-shaped viscometer in beagle. Correlation between WBV and BW, RBC, HGB, HCT, ALP, CHOL, TP, Globulin, Cl, Fibrinogen was presented.

진공관식 태양열 집열 튜브의 열성능 비교 분석 (A Comparative Analysis on the Thermal Performance of Solar Vacuum Collector Tubes)

  • 현준호;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.15-22
    • /
    • 2003
  • This study deals with the collection of solar energy and its storage in evacuated tubular collector systems for different types of header design, flow passage and heat transfer devices. In order to elicit the most efficient combination of header design, flow passage, heat transfer hardware and operating conditions, a series of tests were done for the four different types of solar collectors utilizing vacuum tubes. The systems studied here either has the evacuated collector tubes with a metal cap on one end or the all-glass evacuated solar collector tubes These evacuated tubular collectors are known to be more efficient than the flat-plate ones in both direct and diffuse solar radiation. Test results show that the system comprised of the all-glass evacuated tubes with U-shaped copper pipes inside outperforms the other configurations. Especially, a rolled copper sheet tightly placed along the inner surface of each inner tube enhances heat transfer between the heated collector surface and the water contained in the U-shaped copper pipe.