• Title/Summary/Keyword: U-Factor

Search Result 1,476, Processing Time 0.026 seconds

Importance of convection during physical vapor transport of Hg2Cl2 in the presence of Kr under environments of high gravitational accelerations

  • Kim, Geug-Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Special attention in the role of convection in vapor crystal growth has been paid since some single crystals under high gravity acceleration of $10g_0$ appear considerably larger than those under normal gravity acceleration ($1g_0$). With increasing the gravity acceleration from $1g_0$ up to $10g_0$, the total molar flux for ${\Delta}T$ = 30 K increases by a factor of 4, while for ${\Delta}T$ = 90, by a factor of 3. The maximum molar fluxes for three different gravity levels of $1g_0$, $4g_0$ and $10g_0$, appear approximately in the neighborhood of y = 0.5 cm, and the molar fluxes show asymmetrical patterns, which indicate the occurrence of either one single or more than one convective cell. As the gravitational level is enhanced form $1g_0$ up to $10g_0$, the intensity of convection is increased significantly through the maximum molar fluxes for ${\Delta}T$ = 30 K and 90 K. At $10g_0$, the maximum total molar flux is nearly invariant for for ${\Delta}T$ = 30 K and 90 K. The total molar flux increases with increasing the gravity acceleration, for $1g_0{\leq}g_y{\leq}10g_0$, and decreases with increasing the partial pressure of component B, a noble gas called as Kr (Krypton), $P_B$. The ${{\mid}U{\mid}}_{max}$ is directly proportional to the gravity acceleration for 20 Torr $P_B{\leq}300$ Torr. As the partial pressure of $P_B$ (Torr) decreases from 300 Torr to 20 Torr, the slopes of the ${{\mid}U{\mid}}_{max}s$ versus the gravity accelerations increase from 0.29 sec to 0.54 sec, i.e. by a factor of 2. The total molar flux of $Hg_2Cl_2$ is first order exponentially decayed with increasing the partial pressure of component B, $P_B$ (Torr) from 20 Torr up to 300 Torr.

A Study on Fatigue Crack Propagation Behavior with Pure-Ti Plate (순수 티타늄 판재의 피로균열 전파거동에 관한 연구)

  • 오세욱;김태형;김득진;임만배
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.92-100
    • /
    • 1995
  • The effect of different anisotropy and stress ratio on fatigue crack propagation behavior was investigated under various stress ratio(R=-0.4, -0.2, 0.2, 0.2, 0.4) using pure titanium sheet used in aerospace, chemical and food industry. The rack closure behavior under constant load amplitude fatigue crack propagation test was examined. Fatigue crack propagation rate da/dN was estimated in terms of effective stress intensity factor range, $\Delta$K$_{eff}$, regardless of various stress ratio but was influenced by anisotropy. Also, it was found that the effect of anisotropy was considerably decreased but still not negligible when he da/dN was evaluated by a conventional parameter, $\Delta$$K_{eff}$/E and when the modified da/dN.$\sqrt{\varepsilon}_f$ was evaluated by $\Delta$$K_{eff}$/E. On the other hand, da/dN could be evaluated uniquely by effective new parameter, $\Delta$K$_{eff}$/$sigma_{ys}$, regardless of anisotropy, as int he following equation da/dN=C''[\frac{{\Delta}K_{eff}}{{\sigma}_{ys}}]^{n''}. And effective stress intensity factor range ratio, U was estimated by the following equation with respect to the ratio of reversed plastic zone size, $\Delta r_{p}$ to monotonic plastic zone size, $r_p$ regardless of stress ratio and anisotropy. U=-4.45$(\Delta r_{p}/r_{p})^{2}$+4.1$(\Delta r_{p}/r_{p})$+0.245_{p})$+0.245

  • PDF

Differences of Experts and Non-experts in Perceiving Environmental and Technological Risks (전문가와 비전문가의 환경 및 과학기술 위험에 대한 위해도 인식 차이)

  • Hahm, Myung-Il;Kwon, Ho-Jang;Lee, Hoo-Yeon;Park, Hwa-Gyoo;Lee, Sang-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.269-277
    • /
    • 2009
  • Objective : The objective of this study was to examine how experts and the public perceived various environmental and technological hazards based on psychometric paradigm. Methods : We conducted a survey that included 30 hazards and 10 risk attributes. Subjects of this study were 214 people with three groups; (1) experts (55 people), (2) graduates( 78 people), (3) under graduates (81 people). Factor analysis was used to confirm the common risk attribute from 8 risk attributes. Also, multiple regression analysis was used to identify factors influencing on perceived risk and benefit of hazards. Results : This study revealed that experts tend to be more tolerant than graduates and under graduate students for the 30 hazards. Using factor analysis, two main factors were identified: factor 1, commonly called "Dread Risk", and factors 2, commonly called, "Unknown Risk" in the literature. We identified that environmental hormone concentration and global warming ranked high in both dread risk and unknown risk. Multiple regression models were used to test the association of perceived social risk and perceived social benefit with two main factors. Dread risk had significant explanatory power on perceived social risk and benefit. We identified that the experts were less likely to perceived dread risk and know more information about the hazards. Conclusions : There were differences of risk perception between experts and lay people. Especially, experts' perception of risk was commonly lower than other people's perception.

Morphological Analyses on Retinal Glial Responses to Glaucomatous Injury Evoked by Venous Cauterization

  • Lee, Ji-Yeon;Shin, Ji-Man;Chun, Myung-Hoon;Oh, Su-Ja
    • Applied Microscopy
    • /
    • v.44 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • Retinal glial responses to hypertensive glaucomatous injury were spatiotemporally surveyed. Retinas as a whole or vertical sections were processed for anti-glial fibrillary acidic protein (GFAP), anti-Iba1, anti-nerve growth factor (NGF), and anti-tumor necrosis factor (TNF)-${\alpha}$ immunohistochemistry for confocal microscopic analyses. The optic nerve head of paired controls was processed for electron microscopy. GFAP positive astrocytes appeared in the nerve fiber layer in the glaucomatous and control retinas, changing from fine protoplasmic to stout fibrous parallel to glaucomatous duration. Iba1 positive microglia appeared in both retinas, and enormous reaction appeared at the latest glaucomatous. M$\ddot{u}$ller reaction detected by GFAP reactivity expanded from the end feet to whole profile following to duration in the glaucomatous. NGF reactivity expended from the end feet to the proximal radial processes of the M$\ddot{u}$ller cells in both retinas according to glaucomatous duration. TNF-${\alpha}$ immunoreactivity in the nerve fiber layer was stronger in both the glaucomatous and controls than in the normal, and exceptionally at the latest glaucomatous was even lower than the normal. The astrocytes in the optic nerve head are interconnected with each other via gap junction. These results demonstrate that astrocyte reaction propagates to the contralateral via physical links, and TNF-${\alpha}$ is correlated with NGF production for neuroprotection in response to hypertensive glaucomatous injury.

Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell (동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석)

  • Kang, Eun-Chul;Park, Yong-Dai;Lee, Euy-Joon;Yun, Tae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF

FE Analysis of Exterior Wide Beam-Column Connections with Bonded Tendon Stress (부착된 프리스트레스 넓은 보-기둥 외부접합부의 유한요소해석)

  • Lee, Moon-Sung;Choi, Yun-Cheul;Lim, Jaei-Hyung;Moon, Jeong-Ho;Choi, Chang-Sick
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.4
    • /
    • pp.307-315
    • /
    • 2008
  • Post-tensioned precast concrete system (PPS) consists of U-shaped precast wide beams and concrete column. The continuity of beam-column joint is provided with the topping concrete on the PC shell beam and post-tensioning. Nonlinear analysis was conducted, using ANSYS, a finite-element analysis program, to obtain data for determining the characteristics of the structure and to allow various parametric analyses for post-tensioned wide beam-column connections. In this analysis, the Solid 65 element was used, in which concrete element had 8 nodes and each node had 3 degrees of freedomIn. Solid 65, the shear-transfer factor reflects a decrease of shear strength for the positions with cracks, as an impact factor to make the analysis value approximate the experiment value. In this study, the behavior of test specineus were most closely predicted to the experimental results, when the shear-transfer coefficient 0.85 was used for a closed crack, and 0.2 was used for an open crack.

Inhibitory Effect of Berberine on TNF-$\alpha$-induced U937 Monocytic Cell Adhesion to HT29 Human Colon Epithelial Cells is Mediated through NF-$\kappa$B Rather than PPAR$\gamma$ (TNF-$\alpha$ 자극에 의한 U937 단핵구 세포의 HT29 대장 상피 세포 부착에 대한 Berberine의 PPAR$\gamma$가 아닌 NF-$\kappa$B 경로를 통한 억제 효과)

  • Park, Su-Young;Lee, Gwang-Ik;Kim, Il-Yeob;Kim, Jung-Ae
    • YAKHAK HOEJI
    • /
    • v.54 no.2
    • /
    • pp.91-96
    • /
    • 2010
  • Berberine, an isoquinoline alkaloid, has a wide range of pharmacological effects, including anti-inflammation. It has been reported that berberine inhibits experimental colitis through inhibition of IL-8, and that inhibitory effect of berberine on inflammatory cytokine expression is mediated through peroxisome proliferator activated receptor (PPAR)-$\gamma$. In this study, we examined the effects and action mechanism of berberine on the tumor necrosis factor (TNF)-$\alpha$-induced monocyte adhesion to HT29 human colonic epithelial cells, which is commonly used as an in vitro model of inflammatory bowel disease (IBD). Berberine significantly inhibited the TNF-$\alpha$-induced monocyte adhesion to HT29, which is similar to the effect of PDTC, a nuclear factor (NF)-$\kappa$B inhibitor. However, ciglitazone and GW, the ligands of PPAR-$\gamma$, did not suppress the TNF-$\alpha$-induced monocyte adhesion to HT29 cells. In addition, TNF-$\alpha$-induced chemokine expression and NF-$\kappa$B transcriptional activity were significantly inhibited by berberine in a concentration-dependent manner. The results suggest that inhibitory effect of berberine on colitis is mediated through suppression of NF-$\kappa$B and NF-$\kappa$B-dependent chemokine expression.

Study on Correlation between Acoustic Profiles and Fatigue (노권상과 음성 지표간의 상관성에 관한 연구)

  • Cho, Shin-Woong;Park, Young-Bae;Park, Young-Jae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.1
    • /
    • pp.15-35
    • /
    • 2010
  • Objectives : The purpose of this study is to find out the correlation between the Vocal indicators and the 'Buzhongyiqi-Tang questionnaire' and the 'Chalder fatigue scale.' Methods : This study examined the mean value of each factor in the 'Buzhongyiqi-Tang Questionnaire,' 'Chalder fatigue scale' and the different voice indicators conducted on 81 healthy adult participants in relation to the results of the /a/ /e/ /i/ /o/ /u/ pronunciation test. Results : There was significant correlation between the pronunciation of /a/ /e/ /i/ /o/ /u/ vowels' F0 indexes and 'the Deficiency symptoms of Buzhongyiqi-Tang'. The results of the regression analysis showed the following significant findings for each pronouncing vowels: /i/ as a factor for 'the Deficiency symptoms of Buzhongyiqi-Tang'.; /a/ for 'the Consumptive fever of Buzhongyiqi-Tang'.; /i/ for 'the Vocal inflammation of Buzhongyiqi-Tang.; and /e/ as a factor of 'the Chadler physical fatigue'. Conclusions : The study showed a negative correlation between the Fundamental Frequency and the mean value of the questionnaire, which could be understood as higher the fatigue level, increased level of vocal vibration and higher pitch tone compared to the less fatigued group. We expect future studies to conduct research on methods to diagnose other illnesses using the vocal indicators based on the correlation between the vocal index and illnesses prescribed under traditional oriental medicine.

The Impact of Globalization and Factor Abundancy on Income Inequality (세계화와 요소부존도가 소득불평등에 미치는 영향 분석)

  • Choi, Young-Jun;Piao, Dan-Dan
    • Korea Trade Review
    • /
    • v.42 no.6
    • /
    • pp.51-67
    • /
    • 2017
  • This study analyzes the relationship between globalization and income inequality. The empirical model is developed based on Kuznets' hypothesis of the inverse U curve. The effects of factor abundancy and globalization which is characterized by trade and FDI on income inequality are analyzed. 127 member countries of WTO are classified into 4 groups according to GNI. The period of analysis is 21 years from 1995 to 2015. Results show that 3 groups of countries excluding one group that is high income countries supports Kuznets' hypothesis which is the inverse U curve. Secondly, expansion of trade decreases income inequality of middle income countries but increases high and low income countries. Thirdly, FDI increases income inequality of middle and low income countries. Finally, the increase in capital abundancy lowers income inequality because the capital accumulation increases the productivity of labor.

  • PDF

A Study on the Significance of Unit Capacity Factor (Utilization Rate) of Nuclear Power Plants and Measures for Increasing (원전 이용률의 의의 및 증진방안 고찰)

  • Don Kug Lee;Chi Bum Bahn
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.2
    • /
    • pp.87-100
    • /
    • 2022
  • Unit capacity factor (utilization rate) of nuclear power plants (NPPs) is an important performance indicator. Since the first commercial operation of Kori Unit 1 began in April 1978, the utilization rate of domestic NPPs has gradually increased, reaching 90% from the end of the 1990s. However, due to various issues such as the Fukushima accident in 2011, corrosion of the CLP, the utilization rate dropped to 65~80%. In the early 1980s, the utilization rate of the U.S. NPPs was around 60%. However, since 2004, it has been consistently maintained above 90%. Therefore, in this study, we first examined the causes of declining the utilization rate in domestic NPPs. Next, the significances of the utilization rates are reviewed in five aspects: investment capability, electricity rate, safety and export, etc., with discussion on the current status of the utilization rates in the U.S. Based on this, three key factors are derived as the reasons of the increasing: equipment reliability program, on-line maintenance and the pursuit of institutional rationality. And finally, by synthesizing above results, the measures for increasing the utilization rate of domestic NPPs are proposed in terms of equipment management, institutional improvements, and personnel resources.