• Title/Summary/Keyword: Typical set

Search Result 594, Processing Time 0.026 seconds

Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) for quasi Z-Source Inverters based on a Current Observer

  • Bakeer, Abualkasim;Ismeil, Mohamed A.;Orabi, Mohamed
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.610-620
    • /
    • 2017
  • The Finite Control Set-Model Predictive Controller (FCS-MPC) for quasi Z-Source Inverters (qZSIs) is designed to reduce the number of sensors by proposing a current observer for the inductor current. Unlike the traditional FCS-MPC algorithm, the proposed model removes the inductor current sensor and observes the inductor current value based on the deposited prior optimized state as well as the capacitor voltage during this state. The proposed observer has been validated versus a typical MPC. Then, a comparative study between the proposed Modified Finite Control Set-Model Predictive Controller (MFCS-MPC) and a linear PID controller is provided under the same operating conditions. This study demonstrates that the dynamic response of the control objectives by MFCS-MPC is faster than that of the PID. On the other hand, the PID controller has a lower Total Harmonic Distortion (THD) when compared to the MFCS-MPC at the same average switching. Experimental results validate both methods using a DSP F28335.

Tensile and fracture characterization using a simplified digital image correlation test set-up

  • Kumar, Abhishek;Vishnuvardhan, S.;Murthy, A. Ramachandra;Raghava, G.
    • Structural Engineering and Mechanics
    • /
    • v.69 no.4
    • /
    • pp.467-477
    • /
    • 2019
  • Digital image correlation (DIC) is now a popular and extensively used full-field metrology technique. In general, DIC is performed by using a turnkey solution offered by various manufacturers of DIC. In this paper, a simple and economical set-up for DIC is proposed which uses easily accessible digital single-lens reflex (DSLR) camera rather than industrial couple-charged device (CCD) cameras. The paper gives a description of aspects of carrying a DIC experiment which includes experimental set-up, specimen preparation, image acquisition and analysis. The details provided here will be helpful to carry DIC experiments without specialized DIC testing rig. To validate the responses obtained from proposed DIC set-up, tension and fatigue tests on specimens made of IS 2062 Gr. E300 steel are determined. Tensile parameters for a flat specimen and stress intensity factor for an eccentrically-loaded single edge notch tension specimen are evaluated from results of DIC experiment. Results obtained from proposed DIC experiments are compared with those obtained from conventional methods and are found to be in close agreement. It is also noted that the high resolution of DSLR allows the use of proposed approach for fracture characterization which could not be carried out with a typical turnkey DIC solution employing a camera of 2MP resolution.

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

An Experimental Study of Tension Properties on New Developed Up-Set Coupler (Up-Set Coupler 이음철근의 인장특성에 대한 실험적 연구)

  • Sim, Jong-Sung;Park, Cheol-Woo;Kang, Tae-Sung;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.109-115
    • /
    • 2008
  • As structures are getting super-rise and large-sized, introducing the construction methods such as prefabrication of bar-meshes and complex method are being actively discussed to pursue the high quality of reinforced concrete, the simplification of field works, and the reduction of duration, as well as the study on how to connect reinforcing rods, which occurs while applying the same methods, is in progress Also, the pressure welded joint is a kind of method that heats the ends of reinforced bars locally and joint them, and after the pressure welding, the vulnerable part in the reinforced bar occur. Thus, in the construction field, the throughout quality control is necessary because of the delayed duration and the lowered construct ability. In this study, of the traditional lap splice method and the mechanical splice one, the screw coupler, we tried to look into through experiments the prefabrication method of bar-meshes, a typical joint method usually used for the joint parts for PSC structures applying the reinforced bar with its big diameter, and a newly-developed up-set coupler method. And we also examined the characteristic of tensile.

An Analysis of Web-Based Adaptive Math Learning Program Components (웹 기반 맞춤형 수학 학습 프로그램 구성 요소 분석)

  • Huh, Nan
    • East Asian mathematical journal
    • /
    • v.34 no.4
    • /
    • pp.451-462
    • /
    • 2018
  • This study analyzed the learning components of the web-based adaptive math learning programs in order to develop adaptive math learning program using artificial intelligence. The components of the web-based adaptive math learning program set for analysis are classified into learning process presentation, concept learning, problem presentation, problem solving process, and learning result processing then analyzed three programs. As a result of analysis, the typical characteristic of components is that it uses a method of repeatedly presenting the same type of problem in order to learn one concept.

A Study on the Performance of Mechanical Crash Sensors (기계식 충돌 센서의 성능 해석)

  • Kim, K.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.136-142
    • /
    • 1995
  • An analysis model is proposed for the performance prediction of typical ball and tube type mechanical crash sensors based upon mass-spring-viscous gas damping idealization. Also a construction of mechanical crash pulse generator is suggested as an experimental tool for calibration and verification of model predictions. A sensor tuning procedure for a particular set of crash pulses is suggested based upon the analysis model and the experimental tools.

  • PDF

Bounds for the Full Level Probabilities with Restricted Weights and Their Applications

  • Park, Chul Gyu
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.4
    • /
    • pp.489-497
    • /
    • 1996
  • Lower bounds for the full level probabilities are derived under order restrictions in weights. Discussions are made on typical isotonic cones such as linear order, simple tree order, and unimodal order cones. We also discuss applications of these results for constructing conditional likelihood ratio tests for ordered hypotheses in a contingency table. A real data set on torus mandibularis will be analyzed for illustrating the testing procedure.

  • PDF

Study on Warm Precision Forging of Half Axle Gears

  • Jie Zhou;Yong Zhang
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10b
    • /
    • pp.152-157
    • /
    • 2003
  • A typical die-set for enclosed-die forging of half axle gears in double action hydraulic press is presented, the important factors those influence on precision forming of half axle gears are analyzed, warm forming process of half axle gears is simulated by FEM software $DEFORM\_3D$. The results show, that proper die structure and dimension, suitable web thickness and position can improve material filling, ensure full filling of tooth cavity.

  • PDF

ALTERNATIVE FLARE ACTIVITY INDICATOR: MAD

  • MOON Y-J.;YUN H. S.;PARK Y. D.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.323-324
    • /
    • 1996
  • In the present work we introduce a new flare activity indicator, MAD and examine its characteristics by analyzing a set of successive three days' observations of a typical active region, AR2372. The computed MAD is compared with conventional activity indicator such as separator. It is found that. (1) MAD traces very well the separator, (2) it. singles out. local discontinuity of magnetic field lines and (3) it. is a good measure of describing the evolutionary status of active region.

  • PDF

A Comparison of Sliding Mode and Integral Sliding Mode Controls for Robot Manipulators (로봇 매니퓰레이터를 위한 슬라이딩 모드와 적분 슬라이딩 모드 제어의 비교)

  • Yoo, Dong-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.168-172
    • /
    • 2009
  • We compare an integral sliding mode control with a typical sliding mode control for robot manipulators through two primitive tasks: set-point regulation and trajectory tracking control. To prove the asymptotic stability of two methods for robot manipulators, we introduce three important properties in the robot dynamics: skew-symmetry, positive-definiteness, and boundedness of robot parameter matrices and we present one unified control structure using a parametric velocity vector. From illustrative examples, we show that two methods effectively control for robot manipulators.