• 제목/요약/키워드: Typical energy consumption unit

검색결과 9건 처리시간 0.023초

도심(都心) 임대(賃貸)아파트의 에너지 및 상수(上水) 소비(消費) 특성(特性) 분석(分析) (An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment)

  • 서윤규;김주영;홍원화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.261-265
    • /
    • 2008
  • To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072m^2$ per year and they used $604.2MJ/m^2$ Typical energy consumption unit on $74.4m^2$ of area and $448.8MJ/m^2$ on $105.8m^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an Typical energy consumption unit standard through this research, apartments should use energy more efficiently.

  • PDF

도심 임대아파트의 에너지 및 상수 소비 특성에 관한 연구 (An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment)

  • 서윤규;김주영;홍원화
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.39-46
    • /
    • 2009
  • It has been a serious problem to consume the energy of apartment while increasing to use of heating & cooling System because of residence environmental upgrades. Great attention has been shown to the problem of the rental apartment, so there are few reports of energy consumption about the rental apartment in korea. To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072\;m^2$ per year and typical energy consumption unit was $604.2\;MJ/m^2$ on $74.4\;m^2$ of area and $448.8\;MJ/m^2$ on $105.8\;M^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an typical energy consumption unit standard through this research, apartments should use energy more efficiently.

철도와 도로 수송부문의 에너지 소비 및 온실가스 배출 원단위 분석 (An Analysis of Energy Consumption and GHG Emission per Unit of Rail and Road Transportation)

  • 김병관;이진선;김현구;이재영
    • 한국철도학회논문집
    • /
    • 제17권3호
    • /
    • pp.216-222
    • /
    • 2014
  • 일반적으로 철도는 환경적 측면에서 대단히 우수한 수단이며 도로보다 환경적으로 우위성을 갖고 있다고 인식되어왔다. 하지만 아직 우리나라에서는 철도의 환경적 우위성에 대하여 대부분 외국 사례를 인용하여 온 것이 대부분이며 우리의 자료를 바탕으로 정량적으로 분석한 연구가 부족한 것이 현실이다. 이에 본 연구에서는 철도는 철도통계연보와 한국철도공사의 전기업무자료를, 도로는 에너지 총조사보고서를 활동도 자료로 이용하여 여객과 화물의 에너지 소비량을 산정하고 IPCC 2006 가이드라인을 적용하여 Tier1 수준의 온실가스 배출량을 산정하였다. 최종적으로 환경적 영향을 파악하기 위한 차종별로 여객과 화물의 에너지 소비 및 온실가스 배출 원단위를 산정하여 보았다. 또한 철도와 도로 여객수송의 대표적인 수단으로 고속철도와 승용차의 산정결과를 비교하여 보았다.

종합대학의 전력에너지 부하 특성에 관한 연구 (A Study on the Characteristics of Electric Power Consumption of University)

  • 이춘미;김주영;홍원화
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.336-341
    • /
    • 2008
  • For the last half a century, Korea has been experienced rapid economic growth and industrialization development, however they cause serious problems that environment pollution and energy shortage are appeared, and the biggest problem that we are now confronted are required solutions through all over the world. Now, Korea's energy consumption is the 10th in the whole world. Among them, energy for buildings, about 25% in the whole Energy which spend in Korea, is very serious. Especially, the energy consumption of school buildings which have heating & cooling system according to improvements of educational environment are rapidly increasing. These features are explicit in the University, Because it has lots of colleges and facilities for lecture, experiment, and research. Especially, electric power consumption account for 75 percent of energy consumption in educational institutions. Accordingly, it is important to understand and analyze the pattern of electricity energy consumption which is used. This study attempts to appoint the place which is one of university and to investigate the characteristics of energy consumption like electricity, gas, oil.

  • PDF

아파트단지의 특성에 따른 열병합발전도입의 경제성 비교연구 (Economic Feasibility Study for Providing Co-generation System in various Type of Apartment Complexes)

  • 기우봉;김광호
    • 신재생에너지
    • /
    • 제3권1호
    • /
    • pp.27-37
    • /
    • 2007
  • This study is to analyse the feasibility for providing Co-generation plant in Apartment Complex for 4 typical Apartment Complexes located Seoul metropolitan area, The selected complexes are three midium-large size Apartment[nearby 35pyoug of floor area] and one complex of small size Apartment[below 25 pyoung of floor area] for comparison. The necessary data for the study were collected with visitation of each site. The study showed very positive result for the three medium-large size Apartment Complexes of which the average floor area is more than 25 pyoungs, while negative result for the Complex of which average floor area is less than 25 pyoungs. Other than floor size it was found that the electric consumption density also influence the economic feasibility. In study the unit fixed cost of the energy produced from Co-generation plant is one third of the unit variable cost[fuel cost] and it seems better to select high thermal efficiency machine for Co-generation plant even with some higher cost of the plant.

  • PDF

Analysis on Application of Flywheel Energy Storage System for offshore plants with Dynamic Positioning System

  • Jeong, Hyun-Woo;Kim, Yoon-Sik;Kim, Chul-Ho;Choi, Sung-Hwan;Yoon, Kyoung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권7호
    • /
    • pp.935-941
    • /
    • 2012
  • This paper describes a study of conventional electrical rig and simulated application of Flywheel Energy Storage system on the power system of the offshore plants with dynamic positioning system with the following aims: improve fuel consumption on engines, prevent blackout and mitigate voltage sags due to pulsed load and fault. Fuel consumption has been analyzed for the generators of the typical drilling rigs compared with the power plant with Flywheel Storage Unit which has an important aid in avoiding power interruption during DP (Dynamic Positioning) operation. The FES (Fly wheel Energy storage System) releases energy very quickly and efficiently to ensure continuity of the power supply to essential consumers such as auxiliary machinery and thrusters upon main power failure. It will run until the standby diesel generator can start and supply the electric power to the facilities to keep the vessel in correct position under DP operation. The proposed backup method to utilize the quick and large energy storage Flywheel system can be optimized in any power system design on offshore plant.

온돌 난방에 대한 동적 시뮬레이션 및 분석 (Method and Analysis of Dynamic Simulation for Ondol Heating)

  • 홍희기;김시환
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.375-382
    • /
    • 2010
  • Ondol heating, a kind of radiant floor heating, is a main method used in housing units in Korea. Building energy simulation including ondol and relevant facilities has not been performed due to its complexity. For evaluating energy consumption and indoor temperature variation, a new method should be proposed. At the present work, a dynamic simulation on ondol heating was tried by combining TRNSYS and EES. Characteristic functions for a pump, hot water coils and a gas boiler were simultaneously solved by EES, and calculated flow rates and supply temperature of hot water were provided as inputs of the active layer of TYPE 56 in TRNSYS. The results by the simulation on a typical housing unit in Korea shows a good trend in a viewpoint of actual behavior of ondol heating.

사례연구를 통한 중규모 공연장의 공조시스템 개선 방안에 관한 연구 (A Case study on the Improvement of Air Conditioning System for Thermal Comfort and Energy Conservation in a Middle-Sized Auditorium)

  • 나수연;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제22권4호
    • /
    • pp.85-96
    • /
    • 2002
  • Recently the number of auditoriums such as theaters, assembly halls, and concert halls is increasing in Korea. Auditoriums have generally large space volume, have a high density of occupancy per unit floor area, compared to other buildings. Since they have relatively high ceilings, some heat may stratify above the occupied zone. The under floor air conditioning system, which is set under seats, is frequently selected in an auditorium, because typical air conditioning system where air is supplied from ceilings often causes drafts and unequal temperature distribution. Therefore, this study aims to suggest basic data for air conditioning system design of a middle-sized auditorium. Features and problems of air conditioning system of an auditorium which has about 500 seats are investigated as a case study. In addition, indoor thermal comfort and cooling energy consumption are analyzed with a CFD program and an energy analysis program.

User-Oriented Energy- and Spectral-Efficiency Tradeoff for Wireless Networks

  • Zhang, Yueying;Long, Hang;Peng, Yuexing;Zheng, Kan;Wang, Wenbo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권2호
    • /
    • pp.216-233
    • /
    • 2013
  • Conventional optimization designs of wireless networks mainly focus on spectral efficiency (SE) as a performance metric. However, as diverse media services are emerging, a green wireless network, which not only meets the quality of experience (QoE) requirements for users and also improves energy efficiency (EE), is the most appropriate solution. In this paper, we firstly propose the unit QoE per Watt, which is termed QoE efficiency (QEE), as a user-oriented metric to evaluate EE for wireless networks. We then analyze which is the kind of wireless resource given priority to use under different scenarios to obtain an acceptable QEE. Particularly, power, delay and data-rate related to QoE are separately addressed for several typical services, such as file download, video stream and web browsing services. Next, the fundamental tradeoffs are investigated between QEE and SE for wireless networks. Our analytical results are helpful for network design and optimization to strike a good balance between the users perceived QoE and energy consumption.