• 제목/요약/키워드: Type C tank

검색결과 163건 처리시간 0.034초

작동유체가 양방향성 태양열 열다이오드의 열성능 변화에 미치는 영향 분석 (Effect of Working Fluids on the Thermal Behavior of a Bi-directional Solar Thermal Diode)

  • 고영주;이헌주;천원기;;임상훈
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.9-17
    • /
    • 2008
  • An experimental investigation has been carried out to study the effects of different working fluids on the behavior and thermal performance of a hi-directional thermodiode. The thermodiode was made up of two rectangular loops mounted between a collector plate and a radiator plate. Rotatable joints between the horizontal and inclined segments of the loops enable easy alteration of the direction of heat transfer. The loops and the tank were filled with a working fluid for effective heat transfer when the thermodiode was forwarded biased. Six different working fluids were tested with thermal conductivity values ranging from 0.1 to $0.56W/m-^{\circ}C$, thermal expansion coefficient values ranging from $1.8\;{\times}10^{-4}$ to $1.3\;{\times}\;10^{-3}\;K^{-1}$, and kinematic viscosity values ranging from $0.65\;{\times}\;10^{-6}$ to $100\;{\times}\;10^{-6}\;m^2/s$. Especially, mixtures of $Al_2O_3$ (30nm Particle) in deionized water have been tested for the volumetric ratios of 0.01, 0.02, 0.03, 0.1, 0.2%. Each experiment was carried out after the loop was filled with a working fluid for effective heat transfer and the thermodiode was forwarded biased. The solar thermodiode was heated by a radiant heater consisting of 20 halogen lamps that generated a heat flux of about $1000\;W/m^2$ on the collector surface. Results are given in terms of temperature development in different parts of the loop as heat is delivered from its hot end to the surrounding atmosphere by the radiator made of copper plates.

독립영양 황탈질 미생물을 이용한 관정형 반응벽체의 현장적용성 연구 (Pilot-scale Applications of a Well-type Reactive Barrier using Autotrophic Sulfur-oxidizers for Nitrate Removal)

  • 이병선;엄재연;이규연;문희선;김양빈;우남칠;이종민;남경필
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권3호
    • /
    • pp.40-46
    • /
    • 2009
  • 독립영양 황탈질 미생물 Thiobacillus denitrificans를 이용한 질산염 오염지하수 정화 기술을 개발하고자, 3열의 관정형 반응벽체(길이 $\times$ 너비 $\times$ 깊이 = $3m\;{\times}\;4\;m\;{\times}\;2\;m$)를 한국농어촌공사 수리시험장(길이 $\times$ 너비 $\times$ 깊이 = $8m\;{\times}\;4\;m\;{\times}\;2\;m$)에 설치하고 현장적용성을 검토하였다. 전자공여체로 총 80 kg의 황입자를, 탈질미생물로 Thiobacillus denitrificans를 준비하였다. 황입자 표면에 Thiobacillus denitrificans를 부착하는 1톤 용량 물통 실험에서, Thiobacillus denitrificans는 질산염 농도 375 mg/L(6.1 mM)의 오염수를 11일 경과 후 ~12% (0.7 mM), 18일 경과 후 ~24%(1.3 mM), 32일 경과 후 ~45%(2.4 mM), 그리고 부착 종료 시(60일)까지 ~52%(2.8 mM)를 제거하며 황입자 표면에 성공적으로 부착 증식하였다. 이후, Thiobacillus denitrificans가 부착된 황입자를 3열의 관정형 반응벽체(각 열 간격 1 m)에 주입하여 황탈질 미생물 관정형 반응벽체를 설치하였다. 초기 질산염 농도 평균 181 mg/L 인 인공오염지하수에 대하여 28일 간 1차 정화실험을 실시하였고, 평균 281 mg/L 인 인공오염지하수에 대하여 14일 간 2차 정화실험을 실시하였다. 1차 실험의 인공오염지하수(2.9 mM)는 1열 반응 후 ~2%(0.06 mM), 2열 반응 후 ~9%(0.27 mM), 3열 반응 후 ~15%(0.44 mM)의 질산염이 제거되었다. 2차 실험의 인공오염지하수(4.5 mM)는 1열 반응 후 ~1%(0.02 mM), 2열 반응 후 ~6%(0.27 mM), 3열 반응 후 ~8%(0.37 mM)가 제거되었다. 실험 기간 중 인공오염지하수의 주입용량은 $1.24\;m^3/d$, 유속은 0.44 m/d를 유지하였고, pH는 6.7~8.3, DO는 0.9~2.8 mg/L 범위로 큰 변화가 없었다. 본 관정형 반응벽체 실험의 낮은 정화효율의 원인은 인공오염지하수에 대한 Thiobacillus denitrificans의 탈질 소요 시간 부족, 관정형 반응벽체의 개별 관정사이로 빠져나가는 인공오염지하수체, 그리고 질산염 환원효소의 활성 및 생성을 억제시키는 용존산소의 상대적으로 높은 농도 때문으로 추정된다. 황탈질 관정형 반응벽체의 현장적용시에는 탈질반응에 필요한 체류시간, 관정형 반응벽체의 개수 및 간격, 그리고 용존산소 농도 등 해당 오염부지의 고유 특성을 고려한 설계가 필요하다.

국내 경수로형 원자로 냉각재 중의 $^{14}C$ 거동 특성 평가 (Evaluation of $^{14}C$ Behavior Characteristic in Reactor Coolant from Korean PWR NPP's)

  • 강덕원;양양희;박경록
    • 방사성폐기물학회지
    • /
    • 제7권1호
    • /
    • pp.1-7
    • /
    • 2009
  • 본 논문은 국내에서 가동되고 있는 3개 로형의 원자로 냉각재로부터 유기 및 무기 $^{14}C$의 특성을 평가하는데 초점을 맞추었다. 주목적은 국내 원전 부지에서 환경으로 방출되는 $^{14}C$에 대한 신뢰할 만 한 특성을 평가하는데 있다. $^{14}C$는 방사성핵종 인벤토리 중 가장 중요한 핵종중의 하나로서 처분장에서의 방출 시나리오에서 가장 중요한 선량 기여 핵종중의 하나이다. $^{14}C$는 반감기가 5,730 년인 순수 베타방출체로써 환경으로의 이동성이 높을 뿐 아니라 생물학적인 유용성이 높다. 최근의 연구결과에 의하면, 유기화합물 형태의 $^{14}C$는 환원환경 하에서 원자로 냉각재내에서 주종을 이루고 있는 것으로 밝혀졌으며 그 외의 유기화합물인 formaldehyde, formic acid 및 acetate도 함께 형성되는 것으로 알려졌다. 그러나 정지화학 처 리 기간인 산성 산화환경 하에서는 산화성 탄소형태로 바뀌면서 $^{14}CO_2$$H^{14}CO_3^-$형으로 바뀌어 지는 것으로 나타났다. 본 연구에서는 원자력발전소의 다양한 처리계통의 시료에 대해 유기 및 무기화학형의 $^{14}C$ 농도를 측정, 평가하였다 원자로 계통 내에서의 $^{14}C$ 인벤토리는 약 3.1 GBq/kg로 나타났으며 냉각재 계통 내에서는 주로 유기화학형 이 주종을 이루고 있었으며 무기화학형은 10% 이내인 것으로 나타났다 용액중의 $^{14}C$ 측정은 기상과 액상으로 분리하여 분석하였다. 정상 운전 중에는 유기화학형의 $^{14}C$가 주종을 이루고 있지만 발전소의 배기구를 통해 방출되는 $^{14}C$의 화학형은 온도, pH, 체적제어탱크의 방출 및 정지화학 처리에 따라 화학형이 달라지고 있는 것으로 나타났다.

  • PDF

발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 (Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source)

  • 강연구;강석원;백이;김영화;장재경;유영선
    • 생물환경조절학회지
    • /
    • 제26권4호
    • /
    • pp.317-323
    • /
    • 2017
  • 쓰레기 소각장이나 산업체의 폐열을 농업에 활용한 사례는 몇몇 있었다. 그러나 온배수를 농업에 활용한 사례는 전무하였으며, 치어, 종패 등을 양식하는 수산업이 대부분이었다. 본 연구에서는 화력발전소의 온배수(폐열)를 열원으로 이용하는 120 RT 규모의 냉난방시스템을 제주특별자치도 서귀포시 안덕면 소재의 $5,280m^2$ 아열대 작물(망고) 재배온실에 설치, 10월에서 다음해 2월까지 약 5개월 동안 난방을 실시하여 난방에너지 비용 절감 효과 등 분석하였다. 난방에너지 비용 절감효과는 면세경유에 대하여 87%이였으며, 또한 발전소의 온배수를 에너지원으로 재활용함으로서 62%의 이산화탄소 배출 저감 효과를 얻었다. 본 연구를 계기로 2015년에 해수가 수열에너지 분야로 재생에너지에 포함되었다. 해수의 표층의 열을 히트펌프를 사용하여 변환시켜 얻은 에너지라는 수열에너지 분야의 기준과 범위를 볼 때, 이는 온배수가 재생에너지에 포함되었다고 말해도 과언이 아닐 것으로 사료된다. 그 이유는 온배수도 해수임에도 불구하고 온도가 일반 해수보다 $7{\sim}8^{\circ}C$ 높아, 일반 해수를 히트펌프의 열원으로 이용하는 것보다 온배수를 열원으로 이용했을 때 히트펌프의 성능이 높기 때문이다. 또한 같은 해 농식품부의 폐열 재이용 시설 지원 사업이 발표되어, 발전소 온배수뿐만 아니라 산업체와 소각장의 폐열을 농업에 활용하면 지원을 받을 수 있게 되었다. 이 사업에 의하여 2015년 당진시, 하동군, 제주시, 곡성군이 선정되었으며, 2016년 태안군, 서귀포시 등이 선정되어, 2016년 말 곡성군과 제주시가 공사를 완료, 농업에 폐열을 활용하고 있으며(제주시는 발전소, 곡성군은 산업체 폐열을 이용하고 있음), 기타 지역은 추진 중이다.

과잉 Zr을 첨가한 MmNi4.5Mn0.5Zrx(x=0, 0.025, 0.05, 0.1) 합금의 수소용기 적용에 관한 연구 (Study on the Application for Hydrogen Storage Tank of MmNi4.5Mn0.5Zrx(x=0, 0.025, 0.05, 0.1) Alloys Containing Excess Zr)

  • 강길구;박승갑;강세선;권호영
    • 한국재료학회지
    • /
    • 제12권8호
    • /
    • pp.624-633
    • /
    • 2002
  • In order to improve the hydrogen storage capacity and the activation properties of the hydrogen storage alloys, the rare-earth metal alloy series, MmN $i_{4.5}$M $n_{0.5}$Z $r_{x}$(x=0, 0.025, 0.05, 0.1), are prepared by adding excess Zr in MmN $i_{4.5}$M $n_{0.5}$ alloy. The various parts in hydrogen storage vessel consisted of copper pipes reached the setting temperature within 4~5 minutes after heat addition, which indicated that storage vessel had a good heat conductivity required in application. The performance test on storage vessel filled with rare-earth metal alloys of 1000 gr was also conducted after hydrogen charging for 10 min at $18^{\circ}C$ under 10 atm. It showed that the average capacity of discharged hydrogen volume was found to be for $MmNi_{4.5}$ $Mn_{0.5}$ and $MmNi_{4.5}$ $Mn_{x}$ 0.5/$Zr_{samples}$ indicated that the released amount of hydrogen for this $AB_{5}$ type alloys was more than 92 % of theoretic value, and also it was found that the optimum discharging temperature for obtaining an appropriate pressure of 3 atm was determined to be $V^{\circ}C$ for $MmNi_{4.5}$ $Mn_{0.5}$$Zr_{x}$(x=0, 0.025, 0.05, 0.1) hydrogen storage alloys. The released amount of these hydrogen storage samples was 125 $\ell$ , 122.4 $\ell$ and 108.15 $\ell$/kg for $MmNi_{4.5}$ $Mn_{0.5}$ $Zr_{0.025}$ $MmNi_{4.5}$M $n_{0.5}$Z $r_{0.05}$, and MmN $i_{4.5}$ Mn_0.5$Zr_{0}$, at $70^{\circ}C$ respectively. Amount of the 2nd phases increase with increase on Zr contents in $MmNi_{4.5}$$Mn_{0.5}$ $Zr_{ 0.1}$/ alloy. This phenomenon indicates that$ ZrNi_3$ in $MmNi_{4.5}$ $Mn_{0.5}$ $Zr_{x}$ / phase, which shows the maximum storage capacity and the strong resistance to intrinsic degradation, is considered as a proper alloy for hydrogen storage. As the Zr contents increase, the activation time and the plateau pressure decreases and sloping of the plateau pressure increases.creases.eases.s.

전투차량용 전기식 연료펌프의 고장분석 및 내열성능 평가 (Failure Analysis and Heat-resistant Evaluation of Electric Fuel Pump for Combat Vehicle)

  • 곽대환
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.634-640
    • /
    • 2020
  • 전투차량의 연료탱크에 설치되어 엔진으로 연료를 이송하는 장치인 전기식 연료펌프에 대하여 고장분석과 내열성능 평가가 수행되었다. 고장의 원인을 파악하기 위하여 직류 전동기가 적용된 연료펌프를 분해하여 검사를 수행하였다. 하우징 내부를 관찰한 결과를 바탕으로 고장 현상을 권선 소손, 브러시 조기 마모, 연료 혼입의 세 가지로 분류하였다. 연료펌프 내부 검사를 실시한 결과를 바탕으로, 과열에 의한 권선 소손을 고장을 발생시킨 주된 원인으로 추정하였다. 이에 따라서 전기식 연료펌프의 권선이 과열로 소손될 가능성을 확인하기 위하여 온도 센서를 고정자 표면과 브러시 홀더에 설치한 후 무부하 조건으로 24시간동안 가동을 실시하였다. 연료펌프의 주변 온도를 68 ℃로 설정하였을 때 고정자 온도는 최대 135.9 ℃까지 상승하였으며, 전동기의 고정자 및 회전자 권선이 소손되었다. 이 결과를 통해서 전기식 연료펌프를 위한 전동기 권선의 내열성능이 부족함을 확인할 수 있었으며, 이를 해결하기 위하여 현재 155 ℃ 이하에서 사용할 수 있는 절연등급 F종의 권선 및 함침액을 180 ℃ 이상에서도 사용할 수 있는 C종 이상의 절연등급으로 대체하도록 제안하였다.

빙어의 난발생과정과 자어의 형태발달 (Eggs Development and Larval Development of the Ice Fish, Hypomesus transpacificus nipponensis McAllister)

  • 한경호;이승주;김용억;명정구
    • 한국수산과학회지
    • /
    • 제29권4호
    • /
    • pp.497-502
    • /
    • 1996
  • 1990년 3월, 경상북도 영덕군 강구면에 위치한 오십천과 경상남도 밀양시 밀양강에서 채집하여 인공수정한 난을 실험실로 운반하여 난발생과정과 부화자어의 성장에 따른 형태변화를 관찰한 결과는 다음과 같다. 1. 빙어의 수정난은 구형의 침성부착난으로 무색 투명하며, 난경은 $0.85\~1.05mm$ (평균 0.97mm, n=50)이다. 2. 부화에 소요된 시간은 평균 $16.5^{\circ}C$에서 약 170시간만에 부화한다. 3. 부화직후의 자어는 전장 $3.85\~4.25mm$ (평균 4.05 mm, n=10)로, 아직 입과 항문이 열려 있지 않고, 눈에 색소포가 착색되어 있으며, 근절수는 $52\~54$개이다. 4. 부화 $4\~5$일째의 자어는 전장이 $5.20\~5.65mm$ (평균 5.37mm, n=10)로 난황은 거의 흡수되고, 눈의 색소는 더욱 짙어진다. 5. 부화 20일째의 후기자어는 전장이 $8.20\~8.55\;mm$(평균 8.38mm, n=10)로 척색말단이 $45^{\circ}$ 각도로 위로 굽어진다. 6. 부화 25일째의 후기자어는 전장이 $9.15\~9.75mm$ (평균 9.63mm, n=10)로 등지느러미와 뒷지느러미에 각각 융기하기 시작하여 원기가 나타난다.

  • PDF

밀폐형 식물생산시스템에서 광질과 광주기에 따른 씀바귀의 생육 (Light Quality and Photoperiod Affect Growth of Sowthistle (Ixeris dentata Nakai) in a Closed-type Plant Production System)

  • 김혜민;강정화;정병룡;황승재
    • 원예과학기술지
    • /
    • 제34권1호
    • /
    • pp.67-76
    • /
    • 2016
  • 본 연구는 밀폐형 식물생산시스템 내에서 광질과 광주기에 따른 씀바귀(Ixeris dentata Nakai)의 생육 증진을 위한 적정 생육환경 조건을 구명하고자 수행되었다. 씀바귀 종자는 240구 플러그 트레이에 파종하였고, 밀폐형 식물생산시스템에서 LED(R:B:W = 8:1:1)하에서 24시간 광주기로 3일간 발아 하였다. 묘는 $230{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$의 광도의 3종류의 광질(R:B:W = 8:1:1, R:W = 3:7, R:B = 8:2)과 4종류의 광주기[24/0, 16/8, 8/16, 4/20 (명기/암기)]하에서 $20cm{\times}20 cm$의 재식밀도로 난괴법으로 배치 하였다. 씀바귀는 정식 후 온도 $21{\pm}2^{\circ}C$, 상대습도 $70{\pm}10%$ 조건에서 40일 동안 재배 되었다. 관수는 담액식 양액 재순환 방식을 이용하였다(pH 7.0, EC $2.0dS{\cdot}m^{-1}$). 24/0(명기/암기)의 광주기 처리와 RW 광질 처리에서 지상부와 지하부의 생체중과 건물중, 엽장, 엽면적은 가장 우수했다. 16/8(명기/암기)의 광주기 처리와 RB 광질에서 엽수는 가장 많았으며, 잎끝마름 발생률은 24/0(명기/암기)의 광주기 처리에서 다른 처리보다 높게 나타났다. 엽록소 값은 16/8(명기/암기) 광주기 처리에서 가장 높았으며 광질에 따른 차이는 없었다. 엽록소형광은 24/0(명기/암기) 광주기 처리에서 다른 처리구에 비해 현저히 낮은 값을 보였다. 결과적으로, 밀폐형 식물공장 시스템 안에서 씀바귀 재배의 경제적인 실현가능성과 생산적인 측면에서 16/8(명기/암기) 광주기 처리, RW의 광질에서 씀바귀를 재배하는 것이 가장 효과적인 것으로 판단된다.

부산지방에서 실내수조를 이용한 무지개송어의 사육실험 (AN EXPERIMENT ON THE HEARING OF RAINBOW TROUT IN THE INDOOR AQUARIUM IN BUSAN)

  • 김인배;조재윤
    • 한국수산과학회지
    • /
    • 제10권4호
    • /
    • pp.267-273
    • /
    • 1977
  • 1977년 4월 25일부터 1977년 11월 10일까지 199일 간실내에서 소형의 순환여과사육장치와 소량의 지하수를 이용하여 하계기온이 높은 부산지방에서 무지개송어의 사육실험을 한 바, 다음과 같이 희망적인 결과를 얻었다. 1. 실험수조 2 (Fig.2)의 크기는 가로, 세로 각각 1m, 높이 67cm의 Stainless 수조로 가운데 직경 20cm, 깊이 20cm 역 원추형의 침전부가 있고 고 끝은 직경 4cm의 파이프에 연결되어 주수되는 물이 수조밖의 Stand pipe를 통하여 밖으로 넘쳐서 배출된다. 수심은 40 cm 정도로 유지되었으며 여과조는 가로 세로 각각 23cm, 깊이 40cm의 플라스틱 통에 깊이 30cm로 직경 약 $3\~5mm$는 zeolite석을 넣어 사용하였고 순환 펌프는 1시간에 약 1030 l 용량으로 순환율은 시간당 약 2.6회였다. 2. 수조에 주수되는 소량의 물이 밖으로 나가면서 찌꺼기를 밖으로 내보내게 되는 장치는 사육수의 수질유지에 크게 도움이 되었다. 3. $17^{\circ}C$ 전후의 지하수를 약 400 l의 사육수에 1분간 0.59 l의 비율로 1일 평균 16시간 주수하였더니 7월하순 평균기온이 $27.36^{\circ}C$ 일 때 사육수의 평균 수온이 $20^{\circ}C\~22^{\circ}C$ 전후로 유지되었으나 무지개송어는 정상적인 성장을 하였다. 4. 간단한 여과장치를 하고 1분간 1 l의 물이 주수된다고 할 때 생산량은 30kg 의 계산이 나온다. 5. 남부지방에서 하계수온 $17^{\circ}C$ 전후의 적당한 지하수와 소형의 여과장치 그리고 개량된 사육수조를 이용하여 무지재송어의 양식이 가능하며 경제적으로도 충분히 성립되고 사료와 여과장치를 개선하면 생산단가는 크게 낮출 수 있고 생각된다.

  • PDF

Myriococcum albomyces가 생산하는 Cellulase에 관한 연구 (Studies on the Cellulase produced by Myriococcum of albomyces)

  • 정동효
    • Applied Biological Chemistry
    • /
    • 제14권1호
    • /
    • pp.59-97
    • /
    • 1971
  • Myriococcum albomycesf가 생산하는 섬유소 분해효소군에 관한 연구로서 호소생산배지 및 조효소의 성질을 규명하고 몇 가지 효소군으로 정제한바 다음과 같은 결과를 얻었다. 1. 밀기울 고채해양의 각 효소 활성은 쌀겨고체배양 및 탈지대두박고체배양의 그것보다 강하였다. 2. 밀기울진탕, 쌀겨진탕배양 및 대두박진탕배양등은 상기의 고체배양보다 각 효소의 활성이 우수하였다. 3. $45^{\circ}C$에서 배양한 것이 배양기의 종류에 관계없이 $37^{\circ}C$$50^{\circ}C$에서 배양한 것보다 각 효소의 활성이 강하였다. 4. CMCase는 무기 질소원보다 유기 질소원을 첨가하므로서 더욱 생성이 촉진되었다. 5. 기본밀기울진탕배양기에 CMC, Avicel, 여지분말 등의 indncer를 첨가 하므로서 각 효소활성은 $1.5{\sim}3$배나 증가되었다. 6. CMC와 Avicel을 inducer로 하여 jar formentor에서 배양할 때 작 효소의 활성은 대개 5일째에 최고에 달하였다. 7. Cellulae 조효소의 최적 pH는 $4.0{\sim}4.5$, pH안정성은 $3.5{\sim}8.0$이였다. 그리고 최적온도는 $65^{\circ}C$ 부근으로 다른 사상균의 cellulase에 비하여 높으며 온도안정성도 $60^{\circ}C$에서 120분으로 거의 실활되지 않았다. 8. 조효소의 활성은 $Ca^{++}$, $Mg^{++}$으로 부활되며, $Hg^{++}$, $Cu^{++}$, $Ag^{+}$는 강한 저해체였다. 그리고 투석으로 약간 그 활성이 저하되었다. 9. 배양액을 여과하고 황산암모니움 분획, DEA-E-sephadex A-25, Amberlite CG-50 및 hydroxy-apatite column chromatography로 Avicel, CMC, 여지 분말에 대하여 활성이 다른 4개의 fraction을 분리 하고 이를 cellulase fraction I, fraction II-a, fraction II-b 및 fraction III라고 명명하였다. 10. 이들 4개의 fraction은 전기 영동, 초원심상 및 자외선흡수 등으로 보아서 단일의 단백질로 생각되었다. 11. Fraction I은 Avicelase활성이 강하고, fraction II-a는 cellobiase 활성이 강하였다. 그리고 fraction II는 CMCase 활성이 강하였으며, fraction III는 CMC 점도감소 활성이 강하였다. 12. 섬유소질을 각 fraction으로 가수분해한 최종산물은 cellobiose 및 glucose였다. 그리고 fraction I과 fraction II-a는 Avicel을 협동적으로 분해하였다. 13. Fraction I의 최적 pH 5.5, fraction II-a는 pH 5.0, fraction II-b는 pH 4.0, fractionIII는 pH $4.0{\sim}4.5$이며, 각 fraction의 pH 안정성은 pH $3.0{\sim}7.0$이였다. 14. Fraction I의 최적온도는 $50^{\circ}C$, fractionII-a는 $55{\sim}60^{\circ}C$, fraction II-b 는 $60^{\circ}C$, fraction III는 $55^{\circ}C$이며 각 fraction의 열안정성은 $55^{\circ}C$ 부근에서 120분으로 거의 실활되지 않고 fraction II-a는 $60^{\circ}C$에서도 특별히 안정하였다. 15. Fraction I과 fraction II-b 활성은 $Ag^{++}$, $Hg^{++}$에 의하여 저해되며 $Ca^{++}$, $Mg^{++}$으로는 부활되었다.

  • PDF